Loading...
HomeMy WebLinkAbout07.07.2026 Planning Commission Agenda Packet PLANNING COMMISSION City Hall—Council Chambers, 3989 Central Ave NE Tuesday, July 07, 2026 6:00 PM AGENDA ATTENDANCE INFORMATION FOR THE PUBLIC Members of the public who wish to attend may do so in-person, or by using Microsoft Teams Meeting at columbiaheightsmn.gov/joinmeeting: ID 252 220 349 450 48, Passcode uH7gL3dY. For questions, please contact Administration at 763-706-3610. Auxiliary aids or other accommodations for individuals with disabilities are available upon request when the request is made at least 72 hours in advance. Please contact Administration at 763 -706-3610 to make arrangements. CALL TO ORDER/ROLL CALL 1. Overview of Boards and Commission Orientation 2. Election of Planning Commission Officers Presenting Item: Ursula Brandt, City Planner MOTION: Move to elect ______________ as Chair of the Planning Commission. MOTION: Move to elect ______________ as Vice Chair of the Planning Commission. MOTION: Move to elect ______________ as Secretary/Treasurer of the Planning Commission. APPROVE MINUTES 3. MOTION: Approve April 7, 2026 Planning Commission Meeting Minutes as presented. PUBLIC HEARINGS This is the public’s opportunity to speak regarding this matter. Speakers that are in -person are asked to complete a Speaker Form and submit it to City Staff. Speakers attending virtually should send a request to speak with this information to the moderator using the chat function and wait to be called on to speak. When speaking, virtual attendees should turn thei r camera on. Speakers should limit their comments to five (5) minutes. Any comments made after the public hearing is closed will not be considered by the Planning Commission and will not be included as part of the formal record for this matter as the item will have been voted on and the item formally closed by the Commission. 4. Consideration of a Variance for reduced parking lot setback for 81 38th Ave NE Presenting Item: Ursula Brandt, City Planner MOTION: Move to close the public hearing and waive the reading of draft Resolution No. 2026-043, there being ample copies available to the public. MOTION: Move to recommend that the City Council approve Resolution No. 2026 -043, a Variance allowing a 0 ft parking setback for 81 38th Ave NE, Columbia Heights, MN 55421. 1 City of Columbia Heights AGENDA July 07, 2026 Planning Commission Page 2 5. Conditional Use Permit and Final Site Plan Approval for a Car Wash at 47th and Central Ave Presenting Item: Ursula Brandt, City Planner MOTION: Move to close the public hearing and waive the readings of draft Resolution No. 2026-042 and resolution 2026-PZ02, there being ample copies available to the public. MOTION: Move to recommend to the City Council approval of Resolution No. 2026 -042, a Conditional Use Permit allowing a Car Wash at the anticipated address of 4707 Central Ave NE, Columbia Heights, MN 55408, subject to the conditions stated in the draft resolution. MOTION: Move to approve Resolution No. 2026-PZ02, a final Site Plan for a Car Wash at the anticipated address of 4707 Central Ave NE, Columbia Heights, MN 55421. OTHER BUSINESS 6. Review Acquisition of 4217 Central Ave NE Presenting Item: Ursula Brandt, City Planner MOTION: Move to waive the reading of Resolution 2026-PZ01, there being ample copies available to the public. MOTION: Move to adopt Resolution 2026-PZ01, a resolution finding that the acquisition of certain land for redevelopment purposes by the Columbia Heights Economic Development Authority is consistent with the City of Columbia Heights’ Comprehensive Plan. ADJOURNMENT Auxiliary aids or other accommodations for individuals with disabilities are available upon request when the request is made at least 72 hours in advance. Please contact Administration at 763-706-3610 to make arrangements. 2 2026 PLANNING COMMISSION 3 Item 1. Incorporated in 1921 as a Home Rule Charter City Weak Mayor -Council Organization City Manager CITY ORGANIZATION 4 Item 1. MAYOR & CITY COUNCIL Amáda Márquez Simula, Mayor 2026 Sustainability Commission Liaison Justice Spriggs, Councilmember 2026 Charter Commission Liaison Rachel James, Council President 2026 Planning Commission Liaison Laurel Deneen, Councilmember 2026 Library Board Liaison Connie Buesgens, Councilmember 2026 Park and Recreation Commission Liaison 5 Item 1. Administration ▪Public Information and Records ▪Council Support ▪Human Resources ▪Communication ▪Elections Finance ▪Disbursements, receipts and billing ▪Payroll ▪Financial Reporting ▪Budgeting ▪Liquor Operations Community Development ▪Planning and Zoning ▪Economic Development ▪Building Inspections Public Works and Engineering ▪Streets and Parks ▪Utilities ▪Public Improvement IT (Information and Technology) ▪Computer Networks, Telephone System, etc. Police ▪Public Safety and Policing ▪Community Oriented Policing ▪Crime Prevention Fire ▪Fire and Emergency Response ▪Emergency Management ▪Commercial Inspections ▪Rental Licensing ▪Property Maintenance Library ▪Public Library Services ▪Adult Enrichment Programming ▪Children Enrichment Programming ▪Public Computer Use Recreation ▪Murzyn Hall Management ▪Youth Sports and Enrichment Programming ▪Senior Fitness and Enrichment Programming ▪Adult and Family Sports and Enrichment Programming CITY DEPARTMENTS & SERVICES 6 Item 1. CITY MISSION Columbia Heights is a vibrant, healthy and connected City. We are here to actively support the community, deliver equitable services, build and strengthen connections, improve upon our past, and uphold our successes. We strive to be better and ensure Columbia Heights is a great place for everyone, today and in the future. 7 Item 1. SHORT TERM GOALS 1. Develop architectural and financial plan for replacement of the Public Works building, especially as it relates to other priorities (before structural failure) 2. Update Parks Master Plan, develop financing plan, and establish interactive communications about the plans with the community 3. Develop Murzyn Hall renovation plan or identify an alternative new community center plan 4. Prepare long-term, comprehensive plans for single family homes transitioning to rental, including increased tenant/renter protections and new rental licensing program (following moratorium) 5. Update the five-year Capital Improvement Plan (CIP) focusing on long term maintenance and replacement of existing facilities 6. Finalize plans for Central Avenue improvements 7. Establish/Re-Establish the City Art Commission and invest in Public Art 8. Find external grants and evaluate establishing a city grant program for Naturally Occurring Affordable Housing (NOAH) properties 9. Develop a formal process to review goals, develop a system of accountability, and communicate with the public regarding the City Council’s goals and strategic plan 10. Build End-to-End communications infrastructure for City buildings and sites 11. Educate staff and elected officials on National Incident Management System (NIMS) 12. Develop and implement integrated online services 13. Complete 43rd and Central PUD approval and initiate construction 14. Improve and expand code enforcement, evaluate point-of-sale program 15. Continue working towards creating a City workforce that accurately represents the community 16. Establish centralized translation services for all departments and provide language support services at all public meetings 17. Strengthen brand awareness across projects, activities, goals, and at the liquor store 8 Item 1. Advise and make recommendations to City Council to inform its decisions. Duties include: Gather citizen input; Promote and inform; Explore alternatives; and Weigh in on proposed policy/projects and provide input. PURPOSE OF BOARDS AND COMMISSIONS 9 Item 1. Meetings: First Tuesday of the month at 6:00 pm. Agendas and related materials distributed 3 days in advance. All items for consideration must be submitted in writing 10 days in advance of meeting with contact info of submitter. 7 members plus non -voting Student Commissioners and Council Liaison. Members are appointed to three -year terms by Council. The Community Development Director, Planner, Building Official and City Attorney shall serve as ex officio members of the Commission. Quorum is 4 members. Officers: Chair, Vice -Chair elected annually. PLANNING COMMISSION 10 Item 1. Authority and duties. The Planning Commission shall have the following authority and duties: (1) The Commission shall prepare a program of work outlining activities to be undertaken by the Commission. Such a program will include an outline of data and information to be assembled as a basis for a city plan, an outline of subjects to be covered by a city plan, and an outline of types of procedure necessary to make the city plan effective. The work program may be revised from time to time. (2) The Commission shall prepare, adopt and maintain a comprehensive city plan for the physical development of the city. Said plan shall include proposed public buildings, street arrangements and improvements, public utility services, parks, playgrounds, and other similar developments, and the projected use of property, density of population, and other matters relating to the physical development of the city. Such a plan may be prepared in sections, each of which shall relate to a major subject of the plan, as outlined in the Commission's program of work. (3) The Commission may from time to time recommend to the Council changes or additions to the city plan or any section thereof whenever changed conditions or further studies by the Commission indicate that such amendment or addition is necessary or desirable. CITY CODE: PLANNING COMMISSION 11 Item 1. (4) (a) The Commission shall certify and submit to the Council an attested copy of the city plan or of any section, amendment, or addition to the city plan and recommend and advise to the Council reasonable and practicable means for putting into effect the plan, or amendments or additions thereto, so that the plan will serve as a pattern and guide for the orderly physical development of the city and as a basis for the efficient expenditure of city funds relating to the subjects of the city plan. (b)Such means shall consist of a zoning plan, the control of subdivision plats, a plan of future streets and street extensions, coordination of the normal public improvements of the city, a long term program of capital expenditures and such other matters as will accomplish the purposes of this section. (5) The Commission shall study and make recommendations for changes to the official plat map within 40 days after any proposed plat, plat subdivision, or change to the plat map has been referred to the Commission for study. CITY CODE: PLANNING COMMISSION 12 Item 1. (a)The Commission may recommend to the Council that the proposal be approved; be disapproved, for specific reasons as are indicated; or proposal be approved after specified changes or revisions are made therein, deferral back to the Commission for review of said revisions or changes may be requested. (b)Upon the advice of the City Engineer, the Commission may recommend that the proposed future extension or widening of city streets be indicated on the plat map. (6)The Commission shall have such duties and functions as are prescribed by the zoning code and shall comply with all procedures provided therein. The Commission shall study and make recommendations on proposed changes to the zoning code and report thereon to the Council. (7)Prior to adoption of any amendment or change to the city plan or the zoning code, the Commission shall hold at least one public hearing with ten days' notice of the time and place of such hearing to be published in the official city newspaper. CITY CODE: PLANNING COMMISSION 13 Item 1. (8)The Commission shall list and classify all local public works permanent improvements proposed in the city budget for the ensuing fiscal year that have been referred to the Commission. The Commission shall prepare and recommend a coordinated program of proposed public works for the ensuing fiscal year to the Council and to such other officer, department, board, or governmental bodies as have jurisdiction over the accomplishment of such public work projects. (9)The Commission shall submit to the Council a report of its work during the preceding year on or before January 1 of each year. Said report shall include a copy of the recommended programs of public works projects, as provided by division (8) of this section. (10)The Planning Commission shall perform all duties and functions of the Housing Advisory and Appeals Board, as established by § 6.202(B). CITY CODE: PLANNING COMMISSION 14 Item 1. MEMBER DUTIES Attendance Requirements: Attend meetings. Immediately notify your staff liaison if you will be absent so a quorum can be assured. Notification to City Council will occur if you miss three or more meetings during a year. Review meeting agenda and packet. Must vote on all actions (unless conflict of interest). 15 Item 1. MEMBER DUTIES (CONT.) Effective Members: Recognize that serving the community as a whole is the priority. Advocate and inform. Are proactive. Compromise and work as a team. Do not let personal feelings impact judgment. For further information, please review the League of Minnesota Cities’ Planning Commission Guide . 16 Item 1. STAFF SUPPORT Develops and posts agendas, minutes, and support materials to the website. Resource on City policies and procedures. Helps the commission stay within scope. Provides technical assistance and prepares background memos. Keeps attendance and takes minutes. Meeting setup and coordination. Notifies interested parties of meeting changes. Does not work “for” or at the direction of the board. 17 Item 1. ROLE OF COUNCIL LIAISON Link between Commission and City Council ▪Helps increase Council familiarity of Board ▪Communicates topics that City Council would like discussed Non -voting and generally do not actively participate 18 Item 1. ROLE OF COMMISSION CHAIR Preside over all meetings. Maintain control and order at the meeting. Find ways to engage members. Encourage a positive tone. 19 Item 1. HOW A MEETING IS RUN 1.Commission Chair states the item. 2.Staff member provides overview and background information. 3.Members ask questions and make comments. 4.Item is opened for comment to the public if it is a public hearing. 5.If a public hearing, public hearing is closed after those who wish to speak have and there is another opportunity for member comments and questions. 6.Once discussion has concluded, the board chair will ask for a motion based on the general consensus during the discussion. 7.One member will make a motion and if another agrees they will second. 8.If a motion is made and seconded a vote is made. 9.Motion passes or fails. Additional motions may be proposed. 20 Item 1. OPEN MEETING LAW Gathering of a quorum or more of a public body where the public body discusses, decides, or receives information on issues relating to official business Chance or social gatherings are okay Proper notice ▪At least 3 days in advance ▪Date, Time, Place, Purpose (Agenda) Open to the public Be careful of serial meetings ▪A →B and A →C ▪A →B and B →C 21 Item 1. WEBSITE 22 Item 1. ITEM: Election of Planning Commission Officers Presenting Item: Ursula Brandt, City Planner DEPARTMENT: Community Development BY/DATE: Mitchell Forney, 04/03/2026 CORE CITY STRATEGIES: XCommunity that Grows with Purpose and Equity _High Quality Public Spaces _Safe, Accessible and Built for Everyone _Engaged, Effective and Forward-Thinking _Resilient and Prosperous Economy _Inclusive and Connected Community BACKGROUND Officer Elections are held on an annual basis. In order for a member to be considered for an officer position, they must be nominated by another Planning Commission member or nominate themselves. The election process will go as follows: 1. A Chairperson will be elected. a. Commission members provide all nominations for Chairperson of the Planning Commission. b. A vote is taken and counted individually for each nominated member. c. The member with the most votes is declared the Chairperson of the Planning Commission by the Staff Liaison. 2. A Vice Chairperson will be elected. a. Commission members provide all nominations for Vice Chairperson of the Planning Commission. b. A vote is taken and counted individually for each nominated member. c. The member with the most votes is declared the Vice Chairperson of the Planning Commission by the Staff Liaison. 3. A Secretary/Treasurer will be elected. a. Commission members provide all nominations for Secretary/Treasurer of the Planning Commission. b. A vote is taken and counted individually for each nominated member. c. The member with the most votes is declared the Secretary/Treasurer of the Planning Commission by the Staff Liaison. RECOMMENDED MOTION(S): MOTION: Move to elect ______________ as Chair of the Planning Commission. MOTION: Move to elect ______________ as Vice Chair of the Planning Commission. MOTION: Move to elect ______________ as Secretary/Treasurer of the Planning Commission. PLANNING COMMISSION AGENDA SECTION CALL TO OREDER/ROLL CALL MEETING DATE JULY 7, 2026 23 Item 2. PLANNING COMMISSION City Hall—Council Chambers, 3989 Central Ave NE Tuesday, April 07, 2026 6:00 PM MINUTES ATTENDANCE INFORMATION FOR THE PUBLIC Members of the public who wish to attend may do so in-person, or by using Microsoft Teams Meeting at http://www.columbiaheightsmn.gov/joinameeting ID 234 643 985 190 91, Passcode 2cw7ew3d. For questions, please contact Administration at 763-706-3610. Auxiliary aids or other accommodations for individuals with disabilities are available upon request when the request is made at least 72 hours in advance. Please contact Administration at 763 -706-3610 to make arrangements. CALL TO ORDER/ROLL CALL Commissioners present: Dirk Schmitz, Paul Moses, Clara (Wolfe) Christopherson, Ahmed Maameri Commissioners absent: Jeffrey Johnson, Karl Rehfuss, John Gianoulis Also present: Ursula Brandt, City Planner; Sarah LaVoie, Administrative Assistant; Mitch Forney , Community Development Director; Rachel James, Council Liaison 1. Oath of Office (One Commissioner; April 2026 - March 2029) Christopherson mentioned that the commissioner who was going to take the Oath of Office was not present, and items 1-3 would be tabled until the next meeting. Motion by Moses, seconded by Maameri, to table items one through three until the next Planning Commission meeting. All ayes. MOTION PASSED. 2. Overview of Boards and Commission Orientation This item was tabled. 3. Election of Planning Commission Officers This item was tabled. APPROVE MINUTES 4. MOTION: Approve March 3rd, 2026 Planning Commission Meeting Minutes as presented. 24 Item 3. City of Columbia Heights MINUTES April 07, 2026 Planning Commission Page 2 Motion by Maameri, seconded by Schmitz, to approve the minutes from the meeting of March 03, 2026 All ayes. MOTION PASSED PUBLIC HEARINGS This is the public’s opportunity to speak regarding this matter. Speakers that are in -person are asked to complete a Speaker Form and submit it to City Staff. Speakers attending virtually should send a request to speak with this information to the moderator using the chat function and wait to be called on to speak. When speaking, virtual attendees should turn their camera on. Speakers should limit their comments to five (5) minutes. Any comments made after the public hearing is closed will not be considered by the Planning Commission and will not be included as part of the formal record for this matter as the item will have been voted on and the item formally closed by the Commission. 5. Vacation of Existing Drainage and Utility Easement at 1515 44th Avenue NE Introduction: Brandt stated in 2025 that Duffy Development Company, Inc was selected by Anoka County, the property owner of 1515 44th Avenue NE, to redevelop the lot into an affordable apartment building. The applicant approached Staff to discuss possible options that would be compliant with the current City Code. During this discussion, the applicant noted that the lot had existing easements that, if maintained, would hinder the process of redevelopment. Brandt explained that upon review, the applicant and staff determined that the “utility and drainage easement” labeled Easement ‘B’ is the fire lane easement that allowed fire truck access around the assisted living facility on the adjoining property. A land survey was conducted it was determined that the constructed fire lanes are misaligned with the easements. Brandt reviewed the current status and noted that staff have coordinated with City Engineering and the City Fire Chief to confirm the findings. Comments are attached to the Agenda Packet. Staff will continue to work to ensure that all requirements will be met in the redevelopment of the site for access to the buildings on the adjoining properties. Attached to the Agenda Packet is the plat and land survey identifying the easement to be vacated. Once approved, the applicant is responsible for filing the vacations with Anoka County. Brandt stated the Zoning Ordinance requires the Planning Commission to hold a public hearing on the application for the vacation of a street, alley, or other public right -of-way and submit its recommendation to the City Council. The subject property at 1515 44th Ave NE is zoned R-3 Limited multiple-family residential. The surrounding area is zoned residential, R-3 to the east, R-2A - two-family residential to the west, and R-1 - single-family residential to the south, with open space to the north. Brandt noted that the City’s 2040 Comprehensive Plan guides the subject sites as “High Density Residential” as well as the area to the east, “Low Density Residential” to the south and west, and “Park” space to the north. She reviewed the findings of fact. Section 9.104 (J) of the Zoning Ordinance outlines certain findings of fact that must be met in order for the City to grant approval for an easement vacation. The findings are as follows: The City Council shall make each of the following findings before vacating a street, alley, or other public right-of-way: a) No private rights will be injured or endangered as a result of the vacation. This is correct. 25 Item 3. City of Columbia Heights MINUTES April 07, 2026 Planning Commission Page 3 b) The public will not suffer loss or inconvenience as a result of the vacation. This is correct. Questions/Comments from Members: Schmitz asked if the proposed easement would affect the easement in block two. Brandt replied that it would not affect the block, and the request was strictly for block one. Maameri asked if the Fire Department had any concerns that were resolved. Brandt replied that there were no concerns. Maameri pointed out that the applicants have determined utility and drainage easement and wondered if the fire lane easement allows fire truck access to the assisted living facility. Brandt replied that the Fire Department is still using the paved fire lane, and they will work with the applicant to ensure that the fire lane can be used during construction. Public Hearing Opened. Christopherson opened the Public Hearing. There were no public comments. Public Hearing Closed. (Commissioner comments, if any) Motion by Christopherson, seconded by Moses, to close the public hearing. All ayes. MOTION PASSED. Motion by Moses, seconded by Schmitz, to recommend that the City Council approve Resolution 2026- 019, vacating the drainage and utility easement, easement ‘B’ at 1515 44th Avenue NE as presented. All ayes. MOTION PASSED. Motion by Christopherson, seconded by Moses, to waive the reading of draft Resolution 2026 -019 there being ample copies available to the public. All ayes. MOTION PASSED. 6. Variance for reduced parking requirement for 999 50th Ave NE Introduction: Brandt stated in 2016 that the last remaining tenant, a dental office, vacated the property at 999 50th Avenue, resulting in the building remaining fully vacant to the present day. Over the past decade, City staff have received multiple inquiries regarding potential redevelopment of the site; however, none have advanced to an approved or completed project. Brandt noted that in 2022, A & A Properties acquired the subject property and initiated an evaluation of potential uses for the existing building. The applicant has engaged in ongoing discussions with City staff to identify site constraints and applicable regulatory requirements. Staff has advised that any proposed use would require the building to be brought into compliance with current building and fire codes, including accessibility requirements under the Americans with Disabilities Act and the installation of an approved fire suppression system. 26 Item 3. City of Columbia Heights MINUTES April 07, 2026 Planning Commission Page 4 Brandt explained that based on these discussions, both staff and the applicant have concluded that establishing a viable use within the approximately 12,000 square foot building would present significant challenges. Specifically, compliance with applicable health and safety standards, in combination with the need to maintain a parking demand not exceeding 41 spaces, substantially limits feasible reuse options for the property. Brandt stated A & A Properties is requesting approval of a variance from the off-street parking requirements for the property located at 999 50th Avenue NE. The applicant is proposing to establish a café/restaurant (food service, full-service) within the existing building. For this use, City Code 9.106 (L), requires off-street parking equal to 30 % of the building’s occupant capacity, which results in a requirement of 53 parking spaces. The subject property currently contains 41 parking spaces, resulting in a deficiency of 12 spaces. The applicant seeks a variance f or the following: 1. Variance to allow a 12-space reduction in required parking, from 53 to the existing 41 parking spaces. Brandt noted that the Zoning Ordinance requires the Planning Commission to hold a public hearing on the application for the variance and submit its recommendation to the City Council. The subject property is zoned GB (General Business), and the surrounding area is zoned GB to the east and north, with R-2B (One and Built as Duplex Residential) to the south and R-2A (One and Two Family Residential) to the east. The use of the property as a business and food service complies with the Zoning Code and is otherwise code-compliant. Brandt mentioned that the City’s 2040 Comprehensive Plan guides the subject site as “Commercial” as well as the area to the south, east, and north, and the west as “Medium Density Residential”. The proposed use and parking variance is consistent with the goals and intent of the Comprehensive Plan. Brandt stated that staff have reviewed the variance materials submitted, including floor plans, applicant narrative, and site plan illustrating the proposed use of the building and its relati on to adjacent properties and structures, as well as the existing parking associated with this property. Brandt reviewed the findings of fact. Section 9.104 (G) of the Zoning Ordinance outlines required findings of fact that must be met for the City to grant approval for a Variance. The findings are as follows: The City Council shall make each of the following findings before granting a variance: a) Because of the particular physical surroundings, or the shape, configuration, topography, or other 27 Item 3. City of Columbia Heights MINUTES April 07, 2026 Planning Commission Page 5 conditions of the specific parcel of land involved, strict adherence to the provisions of this article would cause practical difficulties in conforming to the zoning ordinance. The applicant, however, is proposing to use the property in a reasonable manner not permitted by the zoning ordinance. This is correct. Strict adherence to the off-street parking requirements would result in practical difficulties due to the specific conditions of the subject property. The existing building occupies a significant portion of the site, and the parcel is further constrained by surrounding development, limiting the ability to expand or reconfigure the site to accommodate additional parking. In addition, since the construction of the building, the City’s zoning ordinance has been amended, resulting in increased parking requirements. As a result, if the entire building is utilized only three uses allowed in the General Business District could meet current parking standards on this property. Despite these constraints, the applicant is proposing a reasonable use of the property by establishing a café/restaurant within the existing structure, which is consistent with the intent of the zoning district. b) The conditions upon which the variance is based are unique to the specific parcel of land involved and are generally not applicable to other properties within the same zoning classification. This is correct. The site contains an existing building that occupies a substantial portion of the parcel, limiting opportunities for site modification. In addition, physical constraints, including a change in elevation between the subject property and adjacent parcels, restricts the ability to expand parking or establish shared parking arrangements with neighboring properties. These site specific conditions distinguish the property from others in the General Business zoning district. c) The practical difficulties are caused by the provisions of this article and have not been created by any person currently having a legal interest in the property. This is correct. The practical difficulties are not caused by the current property owner or any person having legal interest but due to changes in the zoning code. d) The granting of the variance is in harmony with the general purpose and intent of the Comprehensive Plan. This is correct. The Comprehensive plan calls for reinvestment, renovation, and modernization of the City’s commercial districts. e) The granting of the variance will not be materially detrimental to the public welfare or materially injurious to the enjoyment, use, development or value of property or improvements in the vicinity. 28 Item 3. City of Columbia Heights MINUTES April 07, 2026 Planning Commission Page 6 This is correct. The granting of this variance will result in a new res taurant in a building that has been left vacant for more than a decade. Questions/Comments from Members: Moses asked staff if there was concern about overflow into the Aldi parking lot. Brandt replied that there have been no comments from Aldi, and Aldi received a notice. Maameri asked if there was an ability to have on-street parking. Brandt replied that on-street parking is available outside of the building. She added that staff could work with the Engineering Department to discuss any concerns with the intersection. Moses asked how long the process would take. Forney invited the applicant to speak. Daniel Shay explained that they have not done much planning since they were waiting for approval from the City. The design process will begin after the approval. Maameri clarified that the applicant is asking for a reduction of 12 parking spaces. Brandt agreed. Christopherson added that it is based on the occupancy. Public Hearing Opened. Christopherson opened the Public Hearing. There were no public comments. Public Hearing Closed. Motion by Schmitz, seconded by Christopherson, to close the hearing and waive the reading of draft Resolution No. 2026-026, there being ample copies available to the public. All ayes. MOTION PASSED. Motion by Maameri, seconded by Moses, to recommend that the City Council approve Resolution No. 2026-026, a Variance allowing a 12 parking space reduction for 999 50th Ave NE, Columbia Heights, MN 55408. All ayes. MOTION PASSED. OTHER BUSINESS Brandt stated that the May Planning Commission meeting has been cancelled. She added that there are no new applications. Staff is looking to schedule the kick-off meeting for the Planning Commission and the Advisory Committee for the Comprehensive Planning process for May 6 th. Forney added that the City has pushed forward a Parks Master Plan. He mentioned that the 4300 Central Avenue project is moving forward, and the developer is currently working on the Environmental Assessment Worksheet. Christopherson asked if there had been any progress with the Medtronic site. Forney replied that the brokers are in conversation with other developers for the site. City staff is meeting with the brokers and MnDOT to see if a portion of the property could be used for stormwater ponds. 29 Item 3. City of Columbia Heights MINUTES April 07, 2026 Planning Commission Page 7 Maameri pointed out that the building across the street from City Hall had been sold. Forney agreed and explained that the Fairview building has been sold, and the new building is proposed to be a clinic. Councilmember James mentioned that there would be a Boards and Commission reception at City Hall on April 15th at 5:00 pm. ADJOURNMENT Motion by Christopherson, seconded by Moses to adjourn the meeting at 6:24 pm. All ayes. MOTION PASSED Respectfully submitted, __________________________________________ Ursula Brandt, City Planner 30 Item 3. V PLANNING COMMISSION AGENDA SECTION PUBLIC HEARINGS MEETING DATE JULY 7, 2026 ITEM: Consideration of a Variance for reduced parking lot setback for 81 38th Ave NE. Presenting Item: Ursula Brandt, City Planner DEPARTMENT: Community Development BY/DATE: Ursula Brandt, City Planner, 6/10/26 CORE CITY STRATEGIES: (please indicate areas that apply by adding an “X” in front of the selected text below) X Community that Grows with Purpose and Equity _High Quality Public Spaces _Safe, Accessible and Built for Everyone _Engaged, Effective and Forward-Thinking _Resilient and Prosperous Economy _Inclusive and Connected Community CASE NUMBER: 2026-PZ05 APPLICANT: Millie Kwatt LLC LOCATION: 81 38th Ave NE, Columbia Heights, MN 55421 BACKGROUND: The applicant owns the building at 81 38 th Ave and have run a successful business in this location for decades. In 2012, the applicant first asked for a variance to the parking setback to accommodate the addition of a parking lot to the west of the building. The original request (granted through resolution 2012-050) was to allow for a 0.5ft setback from the side property line to accommodate 18ft by 9ft parking spaces and a 24ft drive aisle. The current request is for a 0 ft setback from the side property lines to accommodate an accessible sidewalk leading to the west entrance along with 18ft by 9ft parking spaces and a 24 ft drive aisle. As noted in 2012, and is still relevant today, a vacation of the California Street right-of-way conducted in the 1990s. The result of the vacation gave an additional 30 ft of land to the subject property . Upon review of the area, it was discovered that there are some city utilities along the right-of-way, but they are buried deep enough to accommodate the construction of a parking lot. The applicant is utilizing the building for office and warehousing. The City Code requires 1 parking s pace for each 300 sqft of office space and 1 parking space for each 3,000 sqft of warehousing. The building has 1,500 sqft of office and 4,500 sqft of warehouse, requiring 7 parking spaces. Currently, the property utilizes approximately 11 parking spaces along the south side of the building, all of which are legal non-conforming for setbacks, and none are handicap accessible. The applicant would like to accommodate more parking on the property by constructing a 5 parking space parking lot to the west of the build ing which includes one handicap accessible parking space located in front of the main entrance to the building. City Code 9.111(C) requires parking areas to be no closer than 20 ft from the front property line, and 5 ft from the side and rear property lines. City Code 9.106(L)(7) prescribes parking spaces to be a minimum of 9 ft wide and 18 ft deep when abutting a curb, and the drive aisle width to access the parking spaces can be no less than 24 ft. To 31 Item 4. Page 2 accommodate the new parking lot the applicant is seeking a variance for the following: 1. Variance to allow for a 0 ft parking lot setback on the west and north property lines and an increased amount of 0 ft setback on the east property line. ZONING ORDINANCE The Zoning Ordinance requires the Planning Commission to hold a public hearing on the application for the variance and submit its recommendation to the City Council. The subject property is zoned I-1 (Industrial), the land to the south and west are also zoned I-1 while the north is zoned PO (Parks and Open Space) and to the east is R3 (Limited Multi-family Residential). The current use of the property as a business complies with the Zoning Code and is otherwise code compliant. COMPREHENSIVE PLAN The City’s 2040 Comprehensive Plan guides the subject site as “Industrial” as well as the area to the south and west. Consistent with the zoning discussed above the Comprehensive Plan guides the property to the north as Open Space and the east as Low Density Residential. A variance to allow for more parking to accommodate the existing use is consistent with the goals and intent of the Comprehensive Plan. CURRENT STATUS Staff has reviewed the variance materials submitted including applicant narrative, site plan and survey illustrating the proposed parking lot and its relation to adjacent properties and structures as well as the existing parking associated with this property. FINDINGS OF FACT Section 9.104 (G) of the Zoning Ordinance outlines required findings of fact that must be met for the City to grant approval for a Variance. The findings are as follows: The City Council shall make each of the following findings before granting a variance: (a) Because of the particular physical surroundings, or the shape, configuration, topography, or other conditions of the specific parcel of land involved, strict adherence to the provisions of this article would cause practical difficulties in conforming to the zoning ordina nce. The applicant, however, is proposing to use the property in a reasonable manner not permitted by the zoning ordinance. This is correct. Due to the current set up of the building on the property there is no direct access to the west and main entrance to the building that is handicap accessible. The applicant is proposing to use the property in a reasonable manner, but is required to first receive a variance to do so. (b) The conditions upon which the variance is based are unique to the specific parcel of land involved and are generally not applicable to other properties within the same zoning classification. This is correct. The conditions upon which the variance is based are a function of the placement of the building on the property in relation to the property lines. While this might not be a specifically unique situation in the City, this is not an occurrence that happens often on industrially zoned parcels. 32 Item 4. Page 3 (c) The practical difficulties are caused by the provisions of this article and have not been cre ated by any person currently having a legal interest in the property. This is correct. The provisions of the Code require a certain dimensional criteria for parking spaces and drive aisle widths. In order to comply with these requirements, the parking lot had to be shifted towards the property lines. For this reason, the provisions of the Code caused the practical difficulties in this matter. (d) The granting of the variance is in harmony with the general purpose and intent of the Comprehensive Plan. This is correct. The Comprehensive Plan guides this area as industrial. A variance to allow for more parking to accommodate the existing use is consistent with the intent of the Comprehensive Plan. (e) The granting of the variance will not be materially detrimental to the public welfare or materially injurious to the enjoyment, use, development or value of property or improvements in the vicinity. This is correct. The proposed placement of the parking lot is next to a City park and unused property. The use of the parking lot will not be materially detrimental; in fact the granting of this variance will result in newly accessible parking allowing better and more equitable access to the existing building. STAFF RECOMMENDATION Staff recommends that the Planning Commission recommend Resolution 2026-043 to the City Council with the following conditions: 1. The variance applies to the zero ft setback for parking to the north and west and an increased utilization of the zero ft setback on the east, if changes are made to the proposed parking lot a reassessment will need to be made. 2. A Building Permit Application must be submitted prior to construction due to the additional parking lot being a proposed accessible route. 3. Must start construction within one year or the variance will be considered null. RECOMMENDED MOTION(S): MOTION: Move to close the public hearing and waive the reading of draft Resolution No. 2026-043, there being ample copies available to the public. MOTION: Move to recommend that the City Council approve Resolution No. 2026-043, a Variance allowing a 0 ft parking setback for 81 38th Ave NE, Columbia Heights, MN 55421. ATTACHMENT(S): 1. Draft Resolution 2. Applicant Narrative 3. Site Location Map 33 Item 4. Page 4 4. Site Plan/Survey 5. Building Department Comments 6. Public Hearing Notice Affidavit 34 Item 4. RESOLUTION NO. 2026-043 A RESOLUTION APPROVING A VARIANCE FOR THE PROPERTY 81 38TH AVE NE COLUMBIA HEIGHTS, MN 55421 BE IT RESOLVED BY the City Council (the “Council”) of the City of Columbia Heights, Minnesota (the “City”) as follows: A proposal (Planning Case 2026-PZ05) has been submitted by Millie Kwatt LLC to the Planning Commission requesting approval of a Variance at the following location: ADDRESS: 81 38th Avenue NE (34-30-24-44-0034) LEGAL DESCRIPTION: COLUMBIA HEIGHTS ANNEX LOTS 16 & 17 BLK 100 COL HGTS ANNEX TO MPLS ACCORDING TO THE RE-RECORDED PLAT THEREOF ON FILE & OF RECORD IN THE OFF OF THE REG OF DEEDS IN & FOR ANOKA CNTY, MN THE APPLICANT SEEKS THE FOLLOWING: 1. Variance to allow a reduction of parking setback to 0 ft for the west side yard and rear yard. City Code Section 9.111 (C) requires parking setback of 5 ft on the side yard and rear yard. The Planning Commission held a public hearing as required by the City Zoning Code on July 7, 2026; The City Council has considered the advice and recommendations of the Planning Commission regarding the effect of the proposed variances upon the health, safety, and welfare of the community and its Comprehensive Plan, as well as any concern related to traffic, property values, light, air, danger of fire, and risk to public safety, in the surrounding area; Now, therefore, in accordance with the foregoing, and all ordinances and regulations of the City of Columbia Heights, the City Council makes the following: FINDINGS OF FACT 1. Because of the particular physical surroundings, or the shape, configuration, topography, or other conditions of the specific parcel of land involved, strict adherence to the provisions of this article would cause practical difficulties in conforming to the zoning ordinance. The applicant, however, is proposing to use the property in a reasonable manner not permitted by the zoning ordinance. 35 Item 4. 2. The conditions upon which the variance is based are unique to the specific parcel of land involved and are generally not applicable to other properties within the same zoning classifications. 3. The practical difficulties are caused by the provisions of this article and have not been created by any person currently having a legal interest in the property. 4. The granting of the variance is in harmony with the general purpose and intent of the Comprehensive Plan. 5. The granting of the variance will not be materially detrimental to the public welfare or materially injurious to the enjoyment, use, development or value of property or improvements in the vicinity. CONDITIONS 1. The variance applies to the zero ft setback for parking to the north and west and an increased utilization of the zero ft setback on the east , if changes are made to the proposed parking lot a reassessment will need to be made. 2. A Building Permit Application must be submitted prior to construction due to the additional parking lot being a proposed accessible route. Must start construction within one year or the variance will be considered nullORDER OF COUNCIL Passed this _________ day of ______________________, 2026 Offered by: Seconded by: Roll Call: Amáda Márquez Simula, Mayor Attest: Sara Ion, City Clerk / Council Secretary 36 Item 4. TO: Columbia Heights Planning and Zoning Location of Variance: 81-38th Ave NE Columbia Heights, MN 55421 Reason for Request: The hardship is for our Handi-Cap clients getting to the front door when the parking lot is on a difference side of the building than the front entrance The location in question is rectangular in shape with a steep hill side and a fence separating my property from the railroad yard on one side and on the North side is a city park. I have very limited parking on the south side of the property. My entrance door faces the lawn area currently, and this does not provide me an area for “Handi-Cap” parking near the entrance door. The company that is using the building provides Tax Preparation Services to the community. Vern and Sandy’s started their MOM and POP company in 1955 and many of the clients have followed them from Johnson Street, Central Ave Lowry Avenue to our final destination here. I am the owner of the building and Vern and Sandy’s/Forsythe is still a family owed company and we would like to accommodate our elderly clients with mobility issues during the winter months. The entrance door of our building used to face California Street until the railroad yard was extended. There is a manhole on this grassy area that add to the complications of upgrading this to a parking lot. There also are 3 wires extending from the telephone poles to the ground to secure the pole from tipping. Larry and Millie Kewatt LLC 37 Item 4. Site Location Map 38 Item 4. 39 Item 4. 40 Item 4. 41 Item 4. ITEM: Conditional Use Permit and Final Site Plan Approval for a Car Wash at 47th and Central Ave Presenting Item: Ursula Brandt, City Planner DEPARTMENT: Community Development BY/DATE: Ursula Brandt, City Planner, 7/2/2026 CORE CITY STRATEGIES: (please indicate areas that apply by adding an “X” in front of the selected text below) X Community that Grows with Purpose and Equity _High Quality Public Spaces _Safe, Accessible and Built for Everyone _Engaged, Effective and Forward-Thinking _Resilient and Prosperous Economy _Inclusive and Connected Community CASE NUMBER: 2026-PZ06 APPLICANT: Kimley-Horn & Associates on behalf of Crew Car Wash DEVELOPMENT: Crew Car Wash LOCATION: 47th and Central Ave. Anticipated address of 4707 Central Ave. (PID: 25-30-24-32- 0182) REQUEST: Conditional Use Permit for Car Wash and Site Plan Approval BACKGROUND In 2003 the subject property along with parcels to the north and east were rezoned to Mixed Use District, with the purpose to promote development and redevelopment by allowing the mix of at least two different uses and providing flexibility on bulk requirements. The site was previously occupied by a Kmart shopping Center. Also in 2003, the first site plan was reviewed and approved for a residential portion of the district resulting in the development of Grand Central Commons which consists of Grand Central Flats, Lofts and Townhomes. PLANNING COMMISSION MEETING AGENDA SECTION PUBLIC HEARINGS MEETING DATE JULY 7, 2026 42 Item 5. City of Columbia Heights - Council Letter Page 2 In 2008, the Planning Commission reviewed and approved a commercial development consisting of office and commercial space, along with a parking ramp. In 2018, a Hy -Vee convenience store/gas station was proposed and approved for the site. However, none of the approved site plans for the commercial portion of the mixed-use district have been developed. CURRENT STATUS The applicant met with the City in May of 2026 to review the requirements to locate a Car Wash on the subject property at the corner of 47th Avenue and Central Ave. Staff relayed the requirements, including the Public Hearing and the Sound Study to th e applicant who submitted their proposal for the Crew Car Wash in June of 2026. ZONING ORDINANCE The Zoning Ordinance requires the Planning Commission to hold a Public Hearing on the application for the Conditional Use Permit and submit its recommendation to the City Council. The subject property is zoned MXD (Mixed-Use District) in a planned development that consisted of Grand Central Flats, Lofts and Townhomes. The subject property and the property to the north are the last undeveloped parcels in the Mixed-Use District. The Zoning Ordinance 9.112 specifies that Mixed-Use developments shall contain at least two of the following three land use categories: Residential Uses, Commercial Uses or Institutional Uses. The district currently only has residential uses in the forms of townhomes, condominiums and apartments. Therefore, the last undeveloped parcels must be either commercial or institutional uses. A car wash is a permitted, with a conditional use permit , commercial use in the Zoning Ordinance and is subject to Specific Development Standards 9.107(10) for a car wash. The proposed site plan, as conditioned, shall meet the following specific development standards: (a) Water from the Car Wash shall not drain across any sidewalk or into any public right -of- way; (b) Vacuum facilities shall be located in an enclosed structure or located at least 50 feet from any residential property line to avoid noise impacts. (c) The premises, all adjacent streets, sidewalks and alleys, and all sidewalks and alleys within 100 feet of the use shall be inspected regularly for the purpose of removing litter found thereon. (d) A sound study is required to determine the overall impact upon the surrounding properties and ensure compliance with performance standards and MPCA sound requirements. (e) All new car washes must me located on a minimum of one acre of land. The proposed site plan shows 12 parking spaces and seven (7) stacking spaces in four (4) lanes for a total queue length of twenty-eight (28) total vehicles at the entrance. The proposed plans show all drainage will be handled on site, but it will be conditioned that there shall be no drainage across any sidewalk or into any public right-of-way. The vacuum facilities are located at a distance significantly above the required 50 ft away from residential property. As sound study was submitted and specifies multiple mitigation techniques that will be used to meet the MPCA sound requirements at all sound points (see Performance Standards). The lot is 1.2305 Acres which is above the required 1 acre. 43 Item 5. City of Columbia Heights - Council Letter Page 3 COMPREHENSIVE PLAN The City’s 2040 Comprehensive Plan guides the subject site as “Commercial” as well as the area to the north and Residential (medium and high density respectively) to the east and south. The City of Hilltop lies to the west. A Conditional Use Permit to allow for a Car Wash is consistent with the goals and intent of the Comprehensive Plan. CONDITIONAL USE PERMIT REVIEW Findings of Fact a) The use is one of the conditional uses listed for the zoning district in which the property is located, or is a substantially similar use as determined by the Zoning Administrator. This is correct. A Car Wash is a permitted, with a conditional use permit, commercial use in the Mixed Use District as code states 9.112 (D)(2) “All permitted, conditional, and permitted accessory commercial uses identified in 9.110, Commercial Districts, which are consistent with the comprehensive plan shall be treated as potentially allowable uses withing the Mixed Use District”. b) The use is in harmony with the general purpose and intent of the comprehensive plan. The City’s 2040 Comprehensive Plan guides the subject site as “Commercial” as well as the area to the north and Residential (medium and high density respectively) to the east and south. The City of Hilltop lies to the west. A Conditional Use Permit to allow for a Car Wash is consistent with the goals and intent of the Comprehensive Plan. c) The use will not impose hazards or disturbing influences on neighboring properties. As conditioned, the proposed use will not impose hazards or disturbing influences on neighboring properties as it has addressed sound, stormwater and traffic concerns. d) The use will not substantially diminish the use of property in the immediate vicinity. The site is located on a main throughfare with other commercial uses and multifamily residential. As conditioned, the proposed use is not expected to negatively impact properties in the immediate vicinity. e) The use will be designed, constructed, operated and maintained in a manner that is compatible with the appearance of the existing or intended character of the surrounding area. The proposed car wash is located within the Highway District as designated in the City’s Design Guidelines. As conditioned, the proposed use and site plan will be designed, constructed, operated and maintained in compliance with the design guidelines and therefore the intended character of the surrounding area. f) The use and property upon which the use is located are adequately served by essential public facilities and services. The proposed property is surrounded by fully developed parcels allowing for adequate access to public utilities along with police and fire services. As conditioned the site will have adequate grading and stormwater management on-site. 44 Item 5. City of Columbia Heights - Council Letter Page 4 g) Adequate measures have been or will be taken to minimize traffic congestion on the public streets and to provide for appropriate on-site circulation of traffic. The proposed site design includes 4 lanes of 7 stacking spaces which holds 28 spaces for vehicles waiting to enter the car wash, while the requirement is only 4 stacking spaces . This is an abundance of off-street stacking spaces that will ease the congestion on the street for those entering the space. There is a two-lane drive aisle that leads to and from the vacuums allowing for adequate flow within the site. h) The use will not cause a negative cumulative effect, when considered in conjunction with the cumulative effect of other uses in the immediate vicinity. As conditioned, the proposed car wash use is not expected to have a negative impact on the immediate vicinity as sound, traffic and stormwater have considered and mitigated where applicable. i) The use complies with all other applicable regulations for the district in which it is located. In review of all the application materials and the proposed use being located within a Mixed Use District, which allows for flexibility, it has been determined the proposed use meets all applicable regulations for the district including the Zoning Ordinance and Design Guidelines. SITE PLAN REVIEW 1. Access Two accesses to the site are proposed from the south via 47th Avenue NE, a 60 ft wide public right of way with a road width of 45 ft back of curb to back of curb, through a 40 ft driveway to the east with directional marking for vehicles entering the car wash and directing to the stacking lanes. There is also a 30 ft driveway to the west with directional markings for vehicles exiting the site. 2. Off-Street Parking Supply Requirements. The submitted site plan illustrates a total of 12 off-street parking stalls. The Zoning Ordinance requires two (2) spaces per bay plus four (4) stacking spaces for the one (1) car wash bay including one (1) stacking space at the exit. The Zoning Ordinance also specifies that employee parking is only required when the parking requirements are based on employee counts, as such, the parking requirements for car washes are determined by the number of service bays and stacking spaces, not employee counts. However, the proposed plans indicate four (4) employee designated parking stalls. Appropriately, one off-street parking spaces on the site has been designated as a disability stall (in accordance with the American Disability Act) along with an access aisle striped with “No Parking”. The proposed site plan has more off-street parking than required and has accounted for employee parking needs. 45 Item 5. City of Columbia Heights - Council Letter Page 5 Use Ratio Required Parking Stalls Provided Parking Car Wash Two (2) parking spaces per bay 2 12 (+10) Automobile washing facility– automatic Four (4) stacking spaces per bay with one (1) space at the bay exit 4 stacking spaces at entrance; 1 stacking space at exit. 4 lanes of 7 stacking spaces at entrance; 2 stacking spaces at exit Total 2 spaces 12 spaces (+10) Dimensional Requirements. The proposed off-street parking stalls meet the minimum dimensional requirements of the Ordinance (9 feet in width and 18 feet for stalls which abut a curb) and the provided 24 foot-wide drive aisle is the minimum width required by the Ordinance. Building, Parking, and Vacuum Area Setbacks. The subject Property is zoned MXD (Mixed Use District) Properties with this zoning designation do not have specific setback or dimensional requirements. This is in order to remain flexible for development proposals. Staff believes the proposal does show reasonable setback, height and dimensional information. Car washes have specific development standards requiring that the vacuum facilities must be located in an enclosed structure or located 50 feet from any residential property lines. The vacuums meet the specific development standard and are setback an excess of 50 feet from residential property lines to the south and east. 3. Business Hours It is understood that the car wash is proposing 7AM – 9PM hours of operation, Monday – Sunday, and any vacuum use shall be limited to hours of operation as a condition of approval. 4. Trash Enclosure and Storage The trash enclosure and storage for this site will be part of the building footprint. The indoor storage area will provide a secure, covered enclosure for landscape and lawn maintenance equipment, snow removal equipment, salt storage and materials for upkeep of the exterior vacuums. Both the trash and storage areas are proposed to be on the southeast corner of the building. 5. Fire Access The applicant has provided a fire access plan that demonstrates Columbia Heights’ fire truck specifics and how the trucks will be able to access the site. The routes are within 150 ft of the entrance and allow the fire trucks to be within 150 ft of all sides of the building. 46 Item 5. City of Columbia Heights - Council Letter Page 6 6. Exterior Lighting The applicant has provided a lighting plan, including light fixture specifics and a photometric study. The proposed plan and fixtures satisfy the requirements of 9.106 General Development Standards (K) by keeping the footcandles at or below 0.5 at the residential property lines and 3 for the Central Ave property line as well as proposing fixtures that are downcast. 7. Loading Area The applicant is not proposing any discernable loading areas and the code requirements for off-street loading spaces apply to non-residential uses receiving or distributing materials or merchandise by trucks or similar vehicles and has a gross floor area of 5,000 sq. ft. or more are not applicable to this proposal. The loading area requirements are satisfied per 9.106 General Development Standards (L) (12) as there are no deliveries beyond standard commercial delivery vehicles (UPS, Fed-Ex, and USPS) occurring at the front door. 8. Landscaping – Tree Preservation and Replanting Standards The applicant meets the Tree Preservation and Replanting Standards in 9.106 General Development Standards (M). All trees that exist on the site are considered volunteer weed trees of undesirable and invasive species and are to be removed with the development. The applicant is required to provide one tree for every 50 feet of street frontage and the property has 446 feet of frontage for a total of nine (9) trees, a minimum of four (4) trees per one acre of lot coverage standards for a total of 13 trees proposed. Additionally, the applicant is proposing landscaping containing native plantings and pollinator friendly h abitats for the majority of the trees, shrubs, and grasses used. The City Forester is satisfied with the proposed landscaping plan. As a condition of approval, the applicant is required to provide a letter of credit or other security as acceptable to the City and shall be deposited with the Zoning Administrator, in an amount equal to 100% of the estimated cost of landscaping and/or screening. The letter of credit or other security as acceptable to the City, or portions thereof, shall be forfeited to maintain and/or replace materials for a period of time to include at least two growing seasons. A portion of the letter of credit or other security as acceptable may be released after one growing season as determined by the Zoning Administrator. The property owner shall be responsible for continued maintenance of landscaping and screening materials to remain in compliance with the requirements of this section. Plant materials that show signs of disease or damage shall be promptly removed and replaced within the next planting season. 9. Building Design The proposed site is considered part of the Highway District in the City Design Guidelines and is subject to the standards and requirements of that design district. The proposed site plan demonstrates compliance with the design objectives of the Highway District, the building is set back from the street behind a parking lot. The architectural renderings and site plan, as conditioned, show compliance with building configuration, façade and roof 47 Item 5. City of Columbia Heights - Council Letter Page 7 treatments, building equipment, drive-through facilities, landscaping and parking meet the design guidelines. It is conditioned that all windows and doors must also meet the design guidelines to ensure only 50% of the window are opaque. Any proposed signage will be subject to the design standards as a condition of approval. 10. Performance Standards (Sound) The applicant has provided a Sound Study that analyzed the sound impact that the car wash and vacuum operations will have on the adjacent residential properties and provided mitigations they will use to decrease the sound impact to meet MPCA standards. The applicant is proposing the following mitigation strategies for the vacuums; reduction in the number of vacuums from 10 to 8, placement of the vacuums at the northern extent of the proposed parking lot, vacuum suction will be generated at a single location within the carwash tunnel, vacuum nozzles will be used that have a lower operational noise levels, and an 8 ft by 20 ft brick noise wall will be installed adjacent to the southernmost vacuum unit. The applicant is also proposing the following mitigation strategies to the design of the tunnel; blower units are to be placed inside the tunnel to allow for a 30 ft sound deadening room adjacent to the tunnel exit, (2) 8 ft tall, 10 ft wide roller doors at each end of the tunnel that will be closed whenever the blower units are active. With the use of the mitigation strategies the Car Wash will meet the MPCA noise standards. 11. Neighborhood Notification As required, neighborhood notification of the conditional use permit application has been provided to property owners within 350 feet of the subject property and that list of property owners is attached. At the time of this report (July 2, 2026), City Staff has received no comments, written or phone calls. 12. Site Plan Staff Review Findings of Fact Section 9.104 (N) of the Zoning Ordinance outlines certain findings of fact that must be met in order for the City to approve a site plan review. The findings are as follows: a) The site plan conforms to all applicable requirements of this article. Upon approval of the Site Plan Review, as conditioned, the proposed site plan will conform to all applicable requirements of City Code 9.106 General Development Standards and 9.107 Specific Development Standards. b) The site plan is consistent with the applicable provisions of the city’s comprehensive plan. The use and site plan are consistent with the applicable provisions of the Comprehensive Plan. The comprehensive plan designates this property as a commercial use; a car wash is consistent with a commercial use. 48 Item 5. City of Columbia Heights - Council Letter Page 8 c) The site plan is consistent with any applicable area plan. With conditions imposed to ensure compatibility, the site plan will be consistent with the applicable Design Guidelines of the Highway District. d) The site plan minimizes any adverse impacts on property in the immediate vicinity and the public right-of-way. As conditioned, the site plan minimizes any adverse impacts on property in the immediate vicinity and the public right-of-way, by providing sound mitigation as well as on-site storm water management. STAFF RECOMMENDATION Staff recommends the Planning Commission recommend approval of the Conditional Use Permit for a Car Wash located at 4707 Central Ave NE. Staff recommends the Planning Commission approve the Site Plan for 4707 Central Ave NE (PID: 25-30-24-32-0182) subject to the following conditions: 1. The Site Plan approval is contingent upon approval of the Conditional Use Permit per resolution 2026-042. 2. The building and site plans adhere to the building and site plans dated July 1, 2026 as conditioned. 3. Building windows and door must meet requirements for the Highway District in the City’s Design Guidelines. 4. The applicant shall submit a building permit application for review and approval prior to construction. 5. All signage shall require sign permits. 6. Fire Access in accordance with Fire Code will be maintained. 7. All City Stormwater Management requirements shall be met. 8. A letter of credit or other security as acceptable to the City and shall be deposited with the Zoning Administrator, in an amount equal to 100% of the estimated cost of landscaping and/or screening. The letter of credit or other security as acceptable to the City, or portions thereof, shall be forfeited to maintain and/or replace materials for a period of time to include at least two growing seasons. A portion of the letter of credit or other security as acceptable may be released after one growing season as determined by the Zoning Administrator. The property owner shall be responsible for continued maintenance of landscaping and screening materials to remain in compliance with the requirements of this section. Plant materials that show signs of disease or damage shall be promptly removed and replaced within the next planting season. 9. Vacuum usage shall be limited to business operating hours only (7AM-9PM). 10. The applicant shall utilize single location vacuum suction from within the carwash tunnel, lower operational noise level nozzles, blower units to be placed inside the tunnel and wide roller doors will be closed while blower is in use to mitigate noise in accordance to the recommendations in the Sound Study. 49 Item 5. City of Columbia Heights - Council Letter Page 9 11. Water from the Car Wash shall not drain across any sidewalk or into any public right -of- way. 12. All rooftop or mechanical equipment shall be screened in a manner that minimizes the visual impact on adjacent properties and from public streets. 13. The building and site shall be meet all requirements found in the Fire Code and the Building Code. 14. All required state and local codes, permits, licenses, and inspections will be met and in full compliance. 15. The applicant is required to receive final approval by the Fire Department or Authority Having Jurisdiction for the location of the keybox, fire alarm panel, fire annunciator, and FDC connection. 16. All exterior lighting shall be downcast as not to adversely impact neighboring resident ial properties. 17. All required state and local codes, permits, licenses, and inspections will be met and in full compliance. RECOMMENDED MOTION(S): MOTION: Move to close the public hearing and waive the readings of draft Resolution No. 2026-042 and resolution 2026-PZ02, there being ample copies available to the public. MOTION: Move to recommend to the City Council approval of Resolution No. 2026-042, a Conditional Use Permit allowing a Car Wash at the anticipated address of 4707 Central Ave NE, Columbia Heights, MN 55408, subject to the conditions stated in the draft resolution. MOTION: Move to approve Resolution No. 2026-PZ02, a final Site Plan for a Car Wash at the anticipated address of 4707 Central Ave NE, Columbia Heights, MN 55421. ATTACHMENTS 1. Narrative 2. Draft Resolution No. 2026-042 3. Resolution 2026-PZ02 4. Civic and Landscape Plans (includes fire access map) 5. Lighting Plan 6. Elevations 7. Sound Study 8. Public Notice with Mailing List 9. Affidavit of Public Notice in the Paper 50 Item 5. RESOLUTION NO. 2026-042 A RESOLUTION APPROVING A CONDITIONAL USE PERMIT FOR THE PROPERTY LOCATED AT 4707 CENTRAL AVE NE COLUMBIA HEIGHTS, MN 55421 BE IT RESOLVED BY the City Council (the “Council”) of the City of Columbia Heights, Minnesota (the “City”) as follows: A proposal (Planning Case # 2026-PZ06) has been submitted by Kimley-Horn & Associates on behalf of Crew Car Wash to the Planning Commission requesting approval of a Conditional Use Permit at the following location: ADDRESS: 4707 Central Ave NE (anticipated address) (PID: 25-30-24-32-0182) EXISTING LEGAL DESCRIPTION: LOT 2 BLOCK 1 GRAND CENTRAL LOFTS 3RD ADD THE APPLICANT SEEKS THE FOLLOWING: 1. Conditional Use Permit to allow an a Car Wash at 4707 Central Ave NE. The Planning Commission held a public hearing as required by the City Zoning Code on July 7, 2026; The Planning Commission has considered the advice and recommendations of the Planning Commission regarding the effect of the proposed Conditional Use Permit upon the health, safety, and welfare of the community and its Comprehensive Plan, as well as any concern related to traffic, property values, light, air, danger of fire, and risk to public safety, in the surrounding area; Now, therefore, in accordance with the foregoing, and all ordinances and regulations of the City of Columbia Heights, the City of Columbia Heights City Council makes the following: FINDINGS OF FACT 1. The use is one of the conditional uses listed for the zoning district in which the property is located, or is a substantially similar use as determined by the Zoning Administrator. 2. The use is in harmony with the general purpose and intent of the comprehensive plan. 3. The use will not impose hazards or disturbing influences on neighboring properties. 4. The use will not substantially diminish the use of property in the immediate vicinity. 5. The use will be designed, constructed, operated and maintained in a manner that is compatible with the appearance of the existing or intended character of the surrounding area. 51 Item 5. 6. The use and property upon which the use is located are adequately served by essential public facilities and services. 7. Adequate measures have been or will be taken to minimize traffic congestion on t he public streets and to provide for appropriate on-site circulation of traffic. 8. The use will not cause a negative cumulative effect, when considered in conjunction with the cumulative effect of other uses in the immediate vicinity. 9. The use complies with all other applicable regulations for the district in which it is located. CONDITIONS 1. The Conditional Use Permit shall be subject to and comply with all conditions contained within the currently approved site plan and any future site plan approvals or amendments approved by the City. 2. The applicant shall submit a building permit application for review and approval prior to construction. 3. Post-construction sound testing is required to demonstrate compliance with the recommendations made in the Sound Study and ensure that the wall meets the MPCA standards for noise. 4. All other applicable local, state, and federal requirements shall be met at all times . 5. Construction must start within one year or the Conditional Use Permit will be considered null. Passed this day of , 2026 Offered by: Seconded by: Roll Call: Amáda Márquez Simula, Mayor Attest: Sara Ion, City Clerk / Council Secretary 52 Item 5. 53 Item 5. RESOLUTION NO. 2026-PZ02 A RESOLUTION OF THE PLANNING COMMISSION APPROVING OF A SITE PLAN REVIEW FOR PROPERTY LOCATED AT 4707 CENTRAL AVENUE NE COLUMBIA HEIGHTS, MN 55421 A proposal (Planning Case # 2026-PZ06) has been submitted by Kimley-Horn & Associates on behalf of Crew Car Wash to the Planning Commission requesting approval of a Site Plan at the following location: ADDRESS: 4707 Central Ave NE (anticipated address) (PID: 25-30-24-32-0182) LEGAL DESCRIPTION: LOT 2 BLOCK 1 GRAND CENTRAL LOFTS 3RD ADD THE APPLICANT SEEKS THE FOLLOWING: 1. Approval of a Site Plan Review for a new construction Car Wash on a 1.2305 acre parcel in accordance with City Code Section 9.104 (N). The Planning Commission held a public hearing as required by the City Zoning Code on July 7, 2026; The Planning Commission has considered the advice and recommendations of the Planning Commission regarding the effect of the proposed site plan upon the health, safety, and welfare of the community and its Comprehensive Plan, as well as any concern related to traffic, property values, light, air, danger of fire, and risk to public safety, in the surrounding area; Now, therefore, in accordance with the foregoing, and all ordinances and regulations of the City of Columbia Heights, the City of Columbia Heights Planning Commission makes the following: FINDINGS OF FACT 1. The site plan conforms to all applicable requirements of this article. 2. The site plan is consistent with the applicable provisions of the City’s comprehensive plan. 3. The site plan is consistent with any applicable area plan. 4. The site plan minimizes any adverse impacts on property in the immediate vicinity and the public right-of-way. CONDITIONS 1. The Site Plan approval is contingent upon approval of the Conditional Use Permit per resolution 2026-042. 54 Item 5. 2. The building and site plans adhere to the building and site plans dated July 1, 2026 as conditioned. 3. Building windows and door must meet requirement s for the Highway District in the City’s Design Guidelines. 4. The applicant shall submit a building permit application for review and approval prior to construction. 5. All signage shall require sign permits. 6. Fire Access in accordance with Fire Code will be maintained. 7. All City Stormwater Management requirements shall be met. 8. A letter of credit or other security as acceptable to the City and shall be deposited with the Zoning Administrator, in an amount equal to 100% of the estimated cost of landscaping and/or screening. The letter of credit or other security as acceptable to the City, or portions thereof, shall be forfeited to maintain and/or replace materials for a period of time to include at least two growing seasons. A portion of the letter of credit or other security as acceptable may be released after one growing season as determined by the Zoning Administrator. The property owner shall be responsible for continued maintenance of landscaping and screening materials to remain in compliance with the requirements of this section. Plant materials that show signs of disease or damage shall be promptly removed and replaced within the next planting season. 9. Vacuum usage shall be limited to business operating hours only (7AM-9PM). 10. The applicant shall utilize single location vacuum suction from within the carwash tunnel, lower operational noise level nozzles, blower units to be placed inside the tunnel and wide roller doors will be closed while blower is in use to mitigate noise in accordance to the recommendations in the Sound Study. 11. Water from the Car Wash shall not drain across any sidewalk or into any public right -of- way. 12. All rooftop or mechanical equipment shall be screened in a manner that minimizes the visual impact on adjacent properties and from public streets. 13. The building and site shall be meet all requirements found in the Fire Code and the Building Code. 14. All required state and local codes, permits, licenses, and inspections will be met and in full compliance. 15. The applicant is required to receive final approval by the Fire Department or Authority Having Jurisdiction for the location of the keybox, fire alarm panel, fire annunciator, and FDC connection. 16. All exterior lighting shall be downcast as not to adversely impact neighboring residential properties. 17. All required state and local codes, permits, licenses, and inspections will be met and in full compliance. 55 Item 5. Passed this 7th day of July, 2026 Offered by: Seconded by: Roll Call: Chairperson Attest: Secretary 56 Item 5. kimley-horn.com 767 Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 June 1, 2026 Ursula Brandt City Planner City of Columbia Heights 3989 Central Avenue NE Columbia Heights, MN 55421 RE: Crew Carwash – Site Plan Application Project Narrative On behalf of Crew Carwash (“Applicant”), we are submitting a Site Plan application for a new carwash facility (the “Project”) located at 4711 Central Ave NE in the City of Columbia Heights. Property Description and Background The Project is located in Columbia Heights between Highway 65/Central Ave NE, 47th Ave NE, and Grand Ave NE on a vacant, undeveloped lot. The current property is divided into two parcels; the Applicant seeks to adjust the current lot line for this project via the Minor Subdivision Application process. Parcel B (referred to as “The Property”) will be 1.23-acres with the adjusted lot line and is located in the MXD-Mixed-Use zoning district, which allows car washes as a permitted use. The Project has been designed in accordance with the minimum design standards of the MXD district and is not seeking any variances from the zoning code requirements. The proposed use of the Property is consistent with the forthcoming City of Columbia Heights 2040 future land use update, which will reclassify the site into the GB – Commercial (General Business) zoning district. Site Design The Project consists of a one-story carwash tunnel with approximately 6,200 square feet of total floor area along with a covered entry canopy and self-service vacuums. The Property currently has public sidewalk along Central Ave NE, 47th Ave NE, and Grand Ave NE with no existing curb cuts. The northern parcel, Parcel A, has right-in/right-out access along Central Ave NE to the west. The Central Ave NE reconstruction project will not affect access to the proposed project in Parcel B. The project will create 2 access points (entrance & exit) to the site along 47th Ave NE. 57 Item 5. Page 2 kimley-horn.com 767 Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Upon entering the Property, customers will enter one of four wash entry lanes where they will either select and pay for their wash from a team member stationed under the canopy or proceed towards an automated scanner if they are an Unlimited Club member. Once payment is complete, an automated gate will open one at a time allowing the customer to proceed towards the wash entrance. If a customer vehicle is rejected from entering the exterior wash, the customer will be directed to exit the wash entry driveway to the west prior to entering the building. On average, customers spend 3-5 minutes from the time they enter the property to the time they depart. After leaving the carwash building, customers will either exit the property or circulate to the west to an available self-service vacuum. The Project will result in an overall increase in impervious surface from the current site development by approximately 65%, since the existing site is a vacant lot with primarily pervious area. Parking and Staffing Parking is provided primarily for Crew Carwash employees, as Customers remain in their vehicle while in the exterior wash tunnel, and only briefly exit their vehicle when choosing to utilize the self- service vacuums. Dedicated parking spaces have been provided for the number of team members expected to be on site at any one time (between 2 and 4 employees). Indoor Trash Enclosure and Storage The trash enclosure and storage for this site will be part of the building footprint. The indoor storage area will provide a secure, covered enclosure for landscape and lawn maintenance equipment, snow removal equipment, salt storage, and materials for upkeep of the exterior vacuums. Snow Storage Snow accumulation will be removed to an off-site location under contract with the snow removal vendor. Nuisance Characteristics The Project is designed to mitigate noise, light, or any other pollution. The vehicle cleaning will occur within the enclosed structures that are acoustically treated to mitigate sound levels produced by the site. Please see the sound study included with this submittal for additional information related to noise level mitigation techniques being installed on the site to meet MPCA sound level requirements. The self-service vacuums are located along the west side of the Property adjacent to Central Ave NE and are only activated when turned on by a customer. It is understood that the zoning code requires open- 58 Item 5. Page 3 kimley-horn.com 767 Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 space vacuum facilities to be at least 50’ from any residential property line to avoid noise impacts; this project meets this criteria. The site lighting will consist of both building and pole-mounted LED light fixtures to fully illuminate the property during opening hours and has been designed to reduce off-site light pollution. Stormwater Management The Project has been designed in accordance with the City of Columbia Heights Surface Water Management Design Standards and the Mississippi Watershed Management Organization (MWMO). The City of Columbia Heights requires that the existing flow rates for the 2, 10, and 100-year 24 hour rainfall events be maintained. In addition, since this project will disturb more than one acre of land, it is required to capture 1.1” of runoff over the net increase in impervious area. Runoff from the proposed impervious areas will be routed to new underground ADS MC-7200 chambers to satisfy the rate control, volume control, and water quality requirements and will provide a single point to collect sediment, oil, and floating debris prior to stormwater runoff flowing offsite into the municipal storm sewer system. Since the underground BMP will utilize infiltration, the volume control requirement shall be met to also satisfy the water quality requirement. Wash Water Reclamation A state-of-the-art wash water recapture system will be installed to clean and recycle the water used for the car wash process. This system both contributes to responsible use and re-use of water on the project, and ensure that any downstream impacts of increased sanitary wastewater flow is minimized. Please contact me at (612) 431-2892 or matt.schwartz@kimley-horn.com should you have any questions or comments about the project. Sincerely, Matt Schwartz, PE Kimley-Horn & Associates Phone: (612) 431-2892 Email: matt.schwartz@kimley-horn.com Enclosure Cc: Travis Smith, Crew Carwash Katherine Rayner, Crew Carwash 59 Item 5. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 0 - C O V E R S H E E T . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 2 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N PR E P A R E D F O R CO V E R S H E E T C000 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E NORTH VICINITY N.T.S.SITE COLUMBIA HEIGHTS, ANOKA COUNTY, MN 1.CONTRACTOR SHALL CONFIRM THAT THE EXISTING CONDITIONS FOR THE SITE MATCH WHAT IS SHOWN ON THE DRAWINGS INCLUDED PRIOR TO CONSTRUCTION. 2.IF REPRODUCED, THE SCALES SHOWN ON THESE PLANS ARE BASED ON A 22x34 SHEET. 3.ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICES COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING POSSESSION AND THE FINAL CONNECTION OF SERVICES. 4.ALL GENERAL CONTRACTOR WORK TO BE COMPLETED (EARTHWORK, FINAL UTILITIES, AND FINAL GRADING) BY THE MILESTONE DATE IN PROJECT DOCUMENTS. NOTES: PROJECT TEAM: OWNER / DEVELOPER CREW CARWASH 11700 EXIT 5 PARKWAY SUITE 100 FISHERS, INDIANA 46037 TELEPHONE: (317) 572-9250 CREW CARWASH COLUMBIA HEIGHTS 4707 CENTRAL AVE NE FOR SITE DEVELOPMENT PLANS Know what'sbelow. before you dig.Call 47TH AVE NE GR A N D A V E CE N T R A L A V E N E Sheet List Table Sheet Number Sheet Title C000 COVER SHEET C100 GENERAL NOTES C101 SURVEY C200 SITE DEMOLITION PLAN C300 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1 C301 EROSION AND SEDIMENT CONTROL PLAN - PHASE 2 C302 EROSION AND SEDIMENT CONTROL DETAILS C303 SWPPP C400 SITE DIMENSION PLAN C401 FIRE CIRCULATION PLAN C402 SITE DETAILS C403 SITE DETAILS C404 SITE DETAILS C500 GRADING AND DRAINAGE PLAN C600 UTILITY PLAN C601 UTILITY DETAILS C602 UTILITY DETAILS C603 UTILITY DETAILS L100 LANDSCAPE PLAN L101 LANDSCAPE DETAILS ENGINEER KIMLEY-HORN AND ASSOCIATES, INC. PREPARED BY: MATT SCHWARTZ 767 EUSTIS STREET, SUITE 100 ST. PAUL, MN 55114 TELEPHONE (651) 645-4197 LANDSCAPE ARCHITECT KIMLEY-HORN AND ASSOCIATES, INC. PREPARED BY: RYAN A. HYLLESTED, PLA 767 EUSTIS STREET, SUITE 100 ST. PAUL, MN 55114 TELEPHONE (651) 645-4197 ARCHITECT CRIPE 9339 PRIORITY WAY W DRIVE, SUITE 100 INDIANAPOLIS, IN 46240 TELEPHONE: (317) 844-6777 SURVEYOR ANDERSON ENGINEERING 13605 1ST AVE. N, SUITE 100 PLYMOUTH MN, 55441 (763) 412-4000 60 Item 5. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 1 - G E N E R A L N O T E S . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 3 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 GENERAL CONSTRUCTION NOTES 1.THE CONTRACTOR AND SUBCONTRACTORS SHALL OBTAIN A COPY OF THE LATEST EDITION OF THE STANDARD SPECIFICATIONS OF THE LOCAL JURISDICTION AND STATE DEPARTMENT OF TRANSPORTATION AND BECOME FAMILIAR WITH THE CONTENTS PRIOR TO COMMENCING WORK. UNLESS OTHERWISE NOTED, ALL WORK SHALL CONFORM AS APPLICABLE TO THESE STANDARDS AND SPECIFICATIONS. 3.PERFORM ALL WORK IN COMPLIANCE WITH APPLICABLE CITY REGULATIONS, STATE CODES, AND O.S.H.A. STANDARDS. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING THE NECESSARY MATERIALS & LABOR TO CONSTRUCT THE FACILITY AS SHOWN AND DESCRIBED IN THE CONSTRUCTION DOCUMENTS, AND IN ACCORDANCE WITH THE SPECIFICATIONS AND REQUIREMENTS OF THE APPROPRIATE APPROVING AUTHORITIES. 4.CONTRACTOR SHALL CLEAR AND GRUB ALL AREAS UNLESS OTHERWISE INDICATED, REMOVING TREES, STUMPS, ROOTS, MUCK, EXISTING PAVEMENT AND ALL OTHER DELETERIOUS MATERIAL. 5.THE EXISTING SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS QUALITY LEVEL "D" UNLESS OTHERWISE NOTED. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF CI/ACSE 38/02, ENTITLED STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF SUBSURFACE QUALITY DATA BY THE FHA. EXISTING UTILITIES SHOWN ARE LOCATED ACCORDING TO THE INFORMATION AVAILABLE TO THE ENGINEER AT THE TIME OF THE TOPOGRAPHIC SURVEY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE ENGINEER. GUARANTEE IS NOT MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN OR THAT THE LOCATION OF THOSE SHOWN ARE ENTIRELY ACCURATE. FINDING THE ACTUAL LOCATION OF ANY EXISTING UTILITIES IS THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE DONE BEFORE COMMENCING ANY WORK IN THE VICINITY. FURTHERMORE, THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES DUE TO THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. THE OWNER OR ENGINEER WILL ASSUME NO LIABILITY FOR ANY DAMAGES SUSTAINED OR COST INCURRED BECAUSE OF THE OPERATIONS IN THE VICINITY OF EXISTING UTILITIES OR STRUCTURES, NOR FOR TEMPORARY BRACING AND SHORING OF SAME. IF IT IS NECESSARY TO SHORE, BRACE, SWING OR RELOCATE A UTILITY, THE UTILITY COMPANY OR DEPARTMENT AFFECTED SHALL BE CONTACTED AND THEIR PERMISSION OBTAINED REGARDING THE METHOD TO USE FOR SUCH WORK. 6.IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE VARIOUS UTILITY COMPANIES WHICH MAY HAVE BURIED OR AERIAL UTILITIES WITHIN OR NEAR THE CONSTRUCTION AREA BEFORE COMMENCING WORK. THE CONTRACTOR SHALL PROVIDE 48 HOURS MINIMUM NOTICE TO ALL UTILITY COMPANIES PRIOR TO BEGINNING CONSTRUCTION. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED CONSTRUCTION PERMITS AND BONDS IF REQUIRED PRIOR TO CONSTRUCTION. 8.THE CONTRACTOR SHALL HAVE AVAILABLE AT THE JOB SITE AT ALL TIMES ONE COPY OF THE CONSTRUCTION DOCUMENTS INCLUDING PLANS, SPECIFICATIONS, GEOTECHNICAL REPORT AND SPECIAL CONDITIONS AND COPIES OF ANY REQUIRED CONSTRUCTION PERMITS. 9.ANY DISCREPANCIES ON THE DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND ENGINEER BEFORE COMMENCING WORK. NO FIELD CHANGES OR DEVIATIONS FROM DESIGN ARE TO BE MADE WITHOUT PRIOR APPROVAL OF THE OWNER AND NOTIFICATION TO THE ENGINEER. 10.ALL COPIES OF COMPACTION, CONCRETE AND OTHER REQUIRED TEST RESULTS ARE TO BE SENT TO THE OWNER DIRECTLY FROM THE TESTING AGENCY. 11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DOCUMENTING AND MAINTAINING AS-BUILT INFORMATION WHICH SHALL BE RECORDED AS CONSTRUCTION PROGRESSES OR AT THE COMPLETION OF APPROPRIATE CONSTRUCTION INTERVALS AND SHALL BE RESPONSIBLE FOR PROVIDING AS-BUILT DRAWINGS TO THE OWNER FOR THE PURPOSE OF CERTIFICATION TO JURISDICTIONAL AGENCIES AS REQUIRED. ALL AS-BUILT DATA SHALL BE COLLECTED BY A STATE PROFESSIONAL LAND SURVEYOR WHOSE SERVICES ARE ENGAGED BY THE CONTRACTOR. 12.ANY WELLS DISCOVERED ON SITE THAT WILL HAVE NO USE MUST BE PLUGGED BY A LICENSED WELL DRILLING CONTRACTOR IN A MANNER APPROVED BY ALL JURISDICTIONAL AGENCIES. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ANY WELL ABANDONMENT PERMITS REQUIRED. 13.ANY WELL DISCOVERED DURING EARTH MOVING OR EXCAVATION SHALL BE REPORTED TO THE APPROPRIATE JURISDICTIONAL AGENCIES WITHIN 24 HOURS AFTER DISCOVERY IS MADE. 14.THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS DO NOT CONFLICT WITH ANY KNOWN EXISTING OR OTHER PROPOSED IMPROVEMENTS. IF ANY CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITE WORK THAT WOULD BE AFFECTED. FAILURE TO NOTIFY OWNER OF AN IDENTIFIABLE CONFLICT PRIOR TO PROCEEDING WITH INSTALLATION RELIEVES OWNER OF ANY OBLIGATION TO PAY FOR A RELATED CHANGE ORDER. 15.SHOULD CONTRACTOR ENCOUNTER ANY DEBRIS LADEN SOIL, STRUCTURES NOT IDENTIFIED IN THE DOCUMENTS, OR OTHER SOURCE OF POTENTIAL CONTAMINATION, THEY SHALL IMMEDIATELY CONTACT THE ENGINEER AND OWNER. 16.CONTRACTOR SHALL NOTIFY OWNER AND/OR ENGINEER 48 HOURS IN ADVANCE OF THE FOLLOWING ACTIVITIES: PRE-CONSTRUCTION MEETING, SUBGRADE PREPARATION, BASE INSTALLATION, ASPHALT INSTALLATION, UNDERGROUND PIPING AND UTILITIES INSTALLATION,INSTALLATION OF STRUCTURES, CHECK VALVES, HYDRANTS, METERS, ETC., SIDEWALK INSTALLATION, CONNECTIONS TO WATER AND SEWER MAINS, TESTS OF UTILITIES. EROSION CONTROL NOTES 1.THE STORM WATER POLLUTION PREVENTION PLAN ("SWPPP") IS COMPRISED OF THE EROSION CONTROL PLAN, THE STANDARD DETAILS, THE PLAN NARRATIVE, ATTACHMENTS INCLUDED IN THE SPECIFICATIONS OF THE SWPPP, PLUS THE PERMIT AND ALL SUBSEQUENT REPORTS AND RELATED DOCUMENTS. 2.ALL CONTRACTORS AND SUBCONTRACTORS INVOLVED WITH STORM WATER POLLUTION PREVENTION SHALL OBTAIN A COPY OF THE STORM WATER POLLUTION PREVENTION PLAN AND THE STATE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM GENERAL PERMIT (NPDES PERMIT) AND BECOME FAMILIAR WITH THEIR CONTENTS. 3.BEST MANAGEMENT PRACTICES (BMP'S) AND CONTROLS SHALL CONFORM TO FEDERAL, STATE, OR LOCAL REQUIREMENTS OR MANUAL OF PRACTICE, AS APPLICABLE. THE CONTRACTOR SHALL IMPLEMENT ADDITIONAL CONTROLS AS DIRECTED BY THE PERMITTING AGENCY OR OWNER. 4.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR COMPLYING WITH THE REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION, AND SHALL MAINTAIN COMPLIANCE WITH APPLICABLE LAWS AND REGULATIONS FOR THE DURATION OF CONSTRUCTION. 5.THE CONTRACTOR SHALL FIELD ADJUST AND/OR PROVIDE ADDITIONAL EROSION CONTROL BMP'S AS NEEDED TO PREVENT EROSION AND OFF-SITE SEDIMENT DISCHARGE FROM THE CONSTRUCTION SITE. LOG AND RECORD ANY ADJUSTMENTS AND DEVIATIONS FROM THE APPROVED EROSION CONTROL PLANS WITHIN THE SWPPP DOCUMENTS STORED IN THE JOB SITE TRAILER. 6.BMPS SHOWN ON THE EROSION AND SEDIMENT CONTROL PLAN, AND IN THE STORM WATER POLLUTION PREVENTION PLAN, SHALL BE MAINTAINED IN FULLY FUNCTIONAL CONDITION AS REQUIRED BY ALL JURISDICTIONS UNTIL NO LONGER REQUIRED FOR A COMPLETED PHASE OF WORK OR FINAL STABILIZATION OF THE SITE. ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE CHECKED BY A CERTIFIED PERSON AT LEAST ONCE EVERY 7 CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A 0.5-INCH OR GREATER RAINFALL EVENT. 7.EROSION & SEDIMENT CONTROL BMPS SHALL BE MAINTAINED IN ACCORDANCE WITH THE FOLLOWING: 7.1.INLET PROTECTION DEVICES AND BARRIERS SHALL BE REPAIRED OR REPLACED IF THEY SHOW SIGNS OF UNDERMINING OR DETERIORATION. 7.2.ALL SEEDED AREAS SHALL BE CHECKED REGULARLY TO VERIFY THAT A HEALTHY STAND OF VEGETATION IS MAINTAINED. SEEDED AREAS SHOULD BE FERTILIZED, WATERED AND RE-SEEDED AS NEEDED. REFER TO THE LANDSCAPE PLAN AND PROJECT SPECIFICATIONS. 7.3.SILT FENCES SHALL BE REPAIRED TO THEIR ORIGINAL CONDITIONS IF DAMAGED. SEDIMENT SHALL BE REMOVED FROM THE SILT FENCES WHEN IT REACHES ONE-THIRD THE HEIGHT OF THE SILT FENCE. 7.4.THE ROCK CONSTRUCTION ENTRANCE(S) SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHTS-OF-WAY. THIS MAY REQUIRE PERIODIC ADDITIONS OF ROCK TOP DRESSING AS CONDITIONS DEMAND. 7.5.THE TEMPORARY PARKING AND STORAGE AREA SHALL BE KEPT IN GOOD CONDITION (SUITABLE FOR PARKING AND STORAGE). THIS MAY REQUIRE PERIODIC ADDITIONS OF TOP DRESSING IF THE TEMPORARY PARKING CONDITIONS DEMAND. 7.6.PERFORM ALL MAINTENANCE OPERATIONS IN A TIMELY MANNER BUT IN NO CASE LATER THAN 2 CALENDAR DAYS FOLLOWING THE INSPECTION. PAVING AND STRIPING NOTES 1.ALL PAVING, CONSTRUCTION, MATERIALS, AND WORKMANSHIP WITHIN JURISDICTION'S RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCAL CITY OR COUNTY SPECIFICATIONS AND STANDARDS, OR THE STATE DOT SPECIFICATIONS AND STANDARDS IF NOT COVERED BY LOCAL CITY OR COUNTY REGULATIONS. 2.ALL SIGNS, PAVEMENT MARKINGS, AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (M.U.T.C.D) AND CITY STANDARDS. 3.CONTRACTOR SHALL FURNISH ALL PAVEMENT MARKINGS FOR FIRE LANES, ROADWAY LANES, PARKING STALLS, ACCESSIBLE PARKING SYMBOLS, ACCESS AISLES, STOP BARS AND SIGNS, AND MISCELLANEOUS STRIPING WITHIN THE PARKING LOT AS SHOWN ON THE PLANS. 4.ALL EXPANSION JOINTS SHALL EXTEND THROUGH THE CURB. 5.THE MINIMUM LENGTH OF OFFSET JOINTS AT RADIUS POINTS SHALL BE 2 FEET. 6.ALL JOINTS, INCLUDING EXPANSION JOINTS WITH REMOVABLE TACK STRIPS, SHALL BE SEALED WITH JOINT SEALANT. 7.THE MATERIALS AND PROPERTIES OF ALL CONCRETE SHALL MEET THE APPLICABLE REQUIREMENTS IN THE A.C.I. (AMERICAN CONCRETE INSTITUTE) MANUAL OF CONCRETE PRACTICE. 8.CONTRACTOR SHALL APPLY A SECOND COATING OVER ALL PAVEMENT MARKINGS PRIOR TO ACCEPTANCE BY OWNER FOLLOWED BY A COAT OF GLASS BEADS AS APPLICABLE PER THE PROJECT DOCUMENTS. 9.ANY EXISTING PAVEMENT, CURBS AND/OR SIDEWALKS DAMAGED OR REMOVED WILL BE REPAIRED BY THE CONTRACTOR AT HIS EXPENSE TO THE SATISFACTION OF THE ENGINEER AND OWNER. 10.BEFORE PLACING PAVEMENT, CONTRACTOR SHALL VERIFY SUITABLE ACCESSIBLE ROUTES (PER A.D.A). GRADING FOR ALL SIDEWALKS AND ACCESSIBLE ROUTES INCLUDING CROSSING DRIVEWAYS SHALL CONFORM TO CURRENT ADA STATE/NATIONAL STANDARDS. IN NO CASE SHALL ACCESSIBLE RAMP SLOPES EXCEED 1 VERTICAL TO 12 HORIZONTAL. IN NO CASE SHALL SIDEWALK CROSS SLOPES EXCEED 2% . IN NO CASE SHALL LONGITUDINAL SIDEWALK SLOPES EXCEED 5%. IN NO CASE SHALL ACCESSIBLE PARKING STALLS OR AISLES EXCEED 2% (1.5% TARGET) IN ALL DIRECTIONS. SIDEWALK ACCESS TO EXTERNAL BUILDING DOORS AND GATES SHALL BE ADA COMPLIANT. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF ADA CRITERIA CANNOT BE MET IN ANY LOCATION PRIOR TO PAVING. NO CONTRACTOR CHANGE ORDERS WILL BE ACCEPTED FOR A.D.A COMPLIANCE ISSUES. 11.MAXIMUM JOINT SPACING IS TWICE THE DEPTH OF THE CONCRETE PAVEMENT IN FEET. GRADING AND DRAINAGE NOTES 1.GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY THE SUITABILITY OF ALL EXISTING AND PROPOSED SITE CONDITIONS INCLUDING GRADES AND DIMENSIONS BEFORE START OF CONSTRUCTION. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES. 2.THE CONTRACTOR SHALL GRADE THE SITE TO THE ELEVATIONS INDICATED AND SHALL ADJUST BMP'S AS NECESSARY AND REGRADE WASHOUTS WHERE THEY OCCUR AFTER EVERY RAINFALL UNTIL A GRASS STAND IS WELL ESTABLISHED OR ADEQUATE STABILIZATION OCCURS. 3.CONTRACTOR SHALL ENSURE THERE IS POSITIVE DRAINAGE FROM THE PROPOSED BUILDINGS SO THAT SURFACE RUNOFF WILL DRAIN BY GRAVITY TO NEW OR EXISTING DRAINAGE OUTLETS. CONTRACTOR SHALL ENSURE NO PONDING OCCURS IN PAVED AREAS AND SHALL NOTIFY ENGINEER IF ANY GRADING DISCREPANCIES ARE FOUND IN THE EXISTING AND PROPOSED GRADES PRIOR TO PLACEMENT OF PAVEMENT OR UTILITIES. 4.CONTRACTOR SHALL PROTECT ALL MANHOLE COVERS, VALVE COVERS, VAULT LIDS, FIRE HYDRANTS, POWER POLES, GUY WIRES, AND TELEPHONE BOXES THAT ARE TO REMAIN IN PLACE AND UNDISTURBED DURING CONSTRUCTION. EXISTING CASTINGS AND STRUCTURES TO REMAIN SHALL BE ADJUSTED TO MATCH THE PROPOSED FINISHED GRADES. 5.BACKFILL FOR UTILITY LINES SHALL BE PLACED PER DETAILS, STANDARDS, AND SPECIFICATIONS SO THAT THE UTILITY WILL BE STABLE. WHERE UTILITY LINES CROSS THE PARKING LOT, THE TOP 6 INCHES SHALL BE COMPACTED SIMILARLY TO THE REMAINDER OF THE LOT. UTILITY DITCHES SHALL BE VISUALLY INSPECTED DURING THE EXCAVATION PROCESS TO ENSURE THAT UNDESIRABLE FILL IS NOT USED. 6.CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT OF 4" OF TOPSOIL AT COMPLETION OF WORK. ALL UNPAVED AREAS IN EXISTING RIGHTS-OF-WAY DISTURBED BY CONSTRUCTION SHALL BE REGRADED AND SODDED. 7.AFTER PLACEMENT OF SUBGRADE AND PRIOR TO PLACEMENT OF PAVEMENT, CONTRACTOR SHALL TEST AND OBSERVE PAVEMENT AREAS FOR EVIDENCE OF PONDING. ALL AREAS SHALL ADEQUATELY DRAIN TOWARDS THE INTENDED STRUCTURE TO CONVEY STORM RUNOFF. CONTRACTOR SHALL IMMEDIATELY NOTIFY OWNER AND ENGINEER IF ANY DISCREPANCIES ARE DISCOVERED. 8.WHERE EXISTING PAVEMENT IS INDICATED TO BE REMOVED AND REPLACED, THE CONTRACTOR SHALL SAW CUT FULL DEPTH FOR A SMOOTH AND STRAIGHT JOINT AND REPLACE THE PAVEMENT WITH THE SAME TYPE AND DEPTH OF MATERIAL AS EXISTING OR AS INDICATED. 9.THE CONTRACTOR SHALL INSTALL PROTECTION OVER ALL DRAINAGE STRUCTURES FOR THE DURATION OF CONSTRUCTION AND UNTIL ACCEPTANCE OF THE PROJECT BY THE OWNER. ALL DRAINAGE STRUCTURES SHALL BE CLEANED OF DEBRIS AS REQUIRED DURING AND AT THE END OF CONSTRUCTION TO PROVIDE POSITIVE DRAINAGE FLOWS. 10.IF DEWATERING IS REQUIRED, THE CONTRACTOR SHALL OBTAIN ANY APPLICABLE REQUIRED PERMITS. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER AND THE DESIGN ENGINEER PRIOR TO ANY EXCAVATION. 11.FIELD DENSITY TESTS SHALL BE TAKEN AT INTERVALS IN ACCORDANCE WITH THE LOCAL JURISDICTIONAL AGENCY OR TO STATE DOT STANDARDS. IN THE EVENT THAT THE CONTRACT DOCUMENTS AND THE JURISDICTIONAL AGENCY REQUIREMENTS ARE NOT IN AGREEMENT, THE MOST STRINGENT SHALL GOVERN. 12.ALL SLOPES AND AREAS DISTURBED BY CONSTRUCTION SHALL BE GRADED AS PER PLANS. THE AREAS SHALL THEN BE SODDED OR SEEDED AS SPECIFIED IN THE PLANS, FERTILIZED, MULCHED, WATERED AND MAINTAINED UNTIL GROWTH IS ESTABLISHED TO MINIMUM COVERAGE OF 70% IN ALL AREAS. ANY AREAS DISTURBED FOR ANY REASON PRIOR TO FINAL ACCEPTANCE OF THE JOB SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. ALL EARTHEN AREAS WILL BE SODDED OR SEEDED AND MULCHED AS SHOWN ON THE LANDSCAPING PLAN. 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF DUST AND DIRT RISING AND SCATTERING IN THE AIR DURING CONSTRUCTION AND SHALL PROVIDE WATER SPRINKLING OR OTHER SUITABLE METHODS OF CONTROL. THE CONTRACTOR SHALL COMPLY WITH ALL GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION. 14.SOD, WHERE CALLED FOR, MUST BE INSTALLED AND MAINTAINED ON EXPOSED SLOPES WITHIN 48 HOURS OF COMPLETING FINAL GRADING, AND AT ANY OTHER TIME AS NECESSARY, TO PREVENT EROSION, SEDIMENTATION OR TURBID DISCHARGES. 15.THE CONTRACTOR SHALL ENSURE THAT LANDSCAPE ISLAND PLANTING AREAS AND OTHER PLANTING AREAS ARE NOT COMPACTED AND DO NOT CONTAIN ROAD BASE MATERIALS. THE CONTRACTOR SHALL ALSO EXCAVATE AND REMOVE ALL UNDESIRABLE MATERIAL FROM ALL AREAS ON THE SITE TO BE PLANTED AND PROPERLY DISPOSED OF IN A LEGAL MANNER. 16.THE CONTRACTOR SHALL INSTALL ALL UNDERGROUND STORM WATER PIPING PER MANUFACTURER'S RECOMMENDATIONS AND STATE DOT SPECIFICATIONS. 17.PAVEMENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATION OF THE SITE SPECIFIC GEOTECHNICAL EVALUATION REPORT AND CITY & STATE DOT SPECIFICATIONS. 18.SPOT ELEVATIONS REPRESENT THE FINISHED SURFACE GRADE OR FLOWLINE OF CURB UNLESS OTHERWISE NOTED. 19.LIMITS OF CONSTRUCTION ARE TO THE PROPERTY LINE UNLESS OTHERWISE SPECIFIED ON THE PLAN. 20.IMMEDIATELY REPORT TO THE OWNER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. 21.THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING UTILITIES, AND SHALL REPAIR ALL DAMAGE TO EXISTING UTILITIES THAT OCCUR DURING CONSTRUCTION WITHOUT COMPENSATION. 22.BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 23.ALL PROPOSED GRADES ONSITE SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE INDICATED ON THE PLANS. ANY SLOPES STEEPER THAN 4:1 REQUIRE EROSION AND SEDIMENT CONTROL BLANKET. 24.ADHERE TO ALL TERMS AND CONDITIONS AS NECESSARY IN THE GENERAL N.P.D.E.S. PERMIT AND STORMWATER POLLUTION PREVENTION PLAN (SWPPP) FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES. 25.ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS GRADE. WATER STORM SEWER & SANITARY SEWER NOTES 1.THE CONTRACTOR SHALL CONSTRUCT GRAVITY SEWER LATERALS, MANHOLES, GRAVITY SEWER LINES, AND DOMESTIC WATER AND FIRE PROTECTION SYSTEM AS SHOWN ON THESE PLANS. THE CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIALS, EQUIPMENT, MACHINERY, TOOLS, MEANS OF TRANSPORTATION AND LABOR NECESSARY TO COMPLETE THE WORK IN FULL AND COMPLETE ACCORDANCE WITH THE SHOWN, DESCRIBED AND REASONABLY INTENDED REQUIREMENTS OF THE CONTRACT DOCUMENTS AND JURISDICTIONAL AGENCY REQUIREMENTS. IN THE EVENT THAT THE CONTRACT DOCUMENTS AND THE JURISDICTIONAL AGENCY REQUIREMENTS ARE NOT IN AGREEMENT, THE MOST STRINGENT SHALL GOVERN. 2.ALL EXISTING UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS FOR UTILITY LOCATION AND COORDINATION IN ACCORDANCE WITH THE NOTES CONTAINED IN THE GENERAL CONSTRUCTION SECTION OF THIS SHEET. 3.THE CONTRACTOR SHALL RESTORE ALL DISTURBED VEGETATION IN KIND, UNLESS SHOWN OTHERWISE. 4.DEFLECTION OF PIPE JOINTS AND CURVATURE OF PIPE SHALL NOT EXCEED THE MANUFACTURER'S SPECIFICATIONS. SECURELY CLOSE ALL OPEN ENDS OF PIPE AND FITTINGS WITH A WATERTIGHT PLUG WHEN WORK IS NOT IN PROGRESS. THE INTERIOR OF ALL PIPES SHALL BE CLEAN AND JOINT SURFACES WIPED CLEAN AND DRY AFTER THE PIPE HAS BEEN LOWERED INTO THE TRENCH. VALVES SHALL BE PLUMB AND LOCATED ACCORDING TO THE PLANS. 5.ALL PIPE AND FITTINGS SHALL BE CAREFULLY STORED FOLLOWING MANUFACTURER'S RECOMMENDATIONS. CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE COATING OR LINING IN ANY D.I. PIPE FITTINGS. ANY PIPE OR FITTING WHICH IS DAMAGED OR WHICH HAS FLAWS OR IMPERFECTIONS WHICH, IN THE OPINION OF THE ENGINEER OR OWNER, RENDERS IT UNFIT FOR USE, SHALL NOT BE USED. ANY PIPE NOT SATISFACTORY FOR USE SHALL BE CLEARLY MARKED AND IMMEDIATELY REMOVED FROM THE JOB SITE, AND SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 6.WATER FOR FIRE FIGHTING SHALL BE MADE AVAILABLE FOR USE BY THE CONTRACTOR PRIOR TO COMBUSTIBLES BEING BROUGHT ON SITE. 7.ALL UTILITY AND STORM DRAIN TRENCHES LOCATED UNDER AREAS TO RECEIVE PAVING SHALL BE COMPLETELY BACK FILLED IN ACCORDANCE WITH THE GOVERNING JURISDICTIONAL AGENCY'S SPECIFICATIONS. IN THE EVENT THAT THE CONTRACT DOCUMENTS AND THE JURISDICTIONAL AGENCY REQUIREMENTS ARE NOT IN AGREEMENT, THE MOST STRINGENT SHALL GOVERN. 8.UNDERGROUND UTILITY LINES SHALL BE SURVEYED BY A STATE LICENSED PROFESSIONAL LAND SURVEYOR PRIOR TO BACK FILLING. 9.CONTRACTOR SHALL PERFORM, AT THEIR OWN EXPENSE, ANY AND ALL TESTS REQUIRED BY THE SPECIFICATIONS AND/OR ANY AGENCY HAVING JURISDICTION. THESE TESTS MAY INCLUDE, BUT MAY NOT BE LIMITED TO, INFILTRATION AND EXFILTRATION, TELEVISION INSPECTION AND A MANDREL TEST ON GRAVITY SEWER. A COPY OF THE TEST RESULTS SHALL BE PROVIDED TO THE UTILITY PROVIDER, OWNER AND JURISDICTIONAL AGENCY AS REQUIRED. 10.BETWEEN WATER AND SEWER MANHOLES AND PIPES, CONTRACTOR SHALL PROVIDE FOR A MINIMUM HORIZONTAL CLEARANCE OF 10-FEET AND A MINIMUM VERTICAL SEPARATION OF 18-INCHES. 11.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER. 12.ALL STORM PIPE ENTERING STRUCTURES SHALL BE GASKETED AND/OR GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT UNLESS OTHERWISE STATED BY CITY AND STATE DESIGN STANDARDS AND SPECIFICATIONS. 13.UNLESS OTHERWISE STATED IN CITY AND STATE DESIGN STANDARDS AND SPECIFICATIONS, ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISH GRADE. LIDS SHALL BE LABELED "STORM SEWER". EXISTING CASTINGS AND STRUCTURES WITHIN PROJECT LIMITS SHALL BE ADJUSTED TO MEET THESE CONDITIONS AND THE PROPOSED FINISHED GRADE. 14.TOPOGRAPHIC INFORMATION IS TAKEN FROM A TOPOGRAPHIC SURVEY BY LAND SURVEYORS. IF THE CONTRACTOR DOES NOT ACCEPT EXISTING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, THEN THE CONTRACTOR SHALL SUPPLY, AT THEIR EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR TO THE OWNER FOR REVIEW. 15.CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME. 16.ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR FROM INVERT IN TO INVERT OUT. 17.ROOF DRAINS SHALL BE CONNECTED TO STORM SEWER BY PREFABRICATED WYES OR AT STORM STRUCTURES. ROOF DRAINS AND TRUCK WELL DRAIN SHALL RUN AT A MINIMUM 2.0% SLOPE, UNLESS NOTED OTHERWISE, AND TIE IN AT THE CENTERLINE OF THE STORM MAIN. 18.PROVIDE INSULATION OF UNDERGROUND ROOF DRAINS AND SANITARY SEWER SERVICES IF ADEQUATE FROST DEPTH CANNOT BE PROVIDED. 19.THE CONTRACTOR SHALL PROTECT EXISTING UNDERGROUND UTILITIES AND APPURTENANCES THAT ARE TO REMAIN FROM DAMAGE DURING CONSTRUCTION OPERATIONS. 20.THE LOCATION OF EXISTING UTILITIES, STORM DRAINAGE STRUCTURES AND OTHER ABOVE AND BELOW-GRADE IMPROVEMENTS ARE APPROXIMATE AS SHOWN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION, SIZE AND INVERT ELEVATIONS OF EACH PRIOR TO THE START OF CONSTRUCTION. 21.A MINIMUM SEPARATION OF 5-FEET IS REQUIRED BETWEEN UNDERGROUND UTILITIES AND TREES UNLESS A ROOT BARRIER IS UTILIZED. 22.GAS, PHONE AND ELECTRIC SERVICES SHOWN FOR INFORMATIONAL PURPOSES ONLY. DRY UTILITY COMPANIES MAY ALTER THE DESIGN LAYOUT DURING THEIR REVIEW. CONTRACTOR TO COORDINATE FINAL DESIGN AND INSTALLATION WITH UTILITY COMPANIES. 23.COORDINATE UTILITY INSTALLATION WITH IRRIGATION DESIGN AND INSTALLATION. 24.ALL DIMENSIONS ARE TO FLOW LINE OF CURB UNLESS OTHERWISE NOTED. PERIMETER WALL DIMENSIONS ARE TO INSIDE WALL FACE. REFERENCE ARCHITECTURAL PLANS FOR EXACT WALL WIDTH AND SPECIFICATIONS. 25.REFERENCE ARCHITECTURAL PLANS (BY OTHERS) FOR EXACT BUILDING DIMENSIONS, MATERIALS SPECIFICATIONS. 26.REFERENCE M.E.P. PLANS (BY OTHERS) FOR MECHANICAL EQUIPMENT DIMENSIONS AND SPECIFICATIONS. 27.CONTRACTOR SHALL REFERENCE STRUCTURAL PLANS (BY OTHERS) FOR FOOTING AND FOUNDATION PAD PREPARATION SPECIFICATIONS. 28.CONTRACTOR SHALL REFERENCE M.E.P PLANS (BY OTHERS) FOR ROUTING OF PROPOSED ELECTRICAL & COMMUNICATIONS SERVICES AND SITE LIGHTING LAYOUT. THIRD PARTY SUPPLEMENTAL INFORMATION KIMLEY-HORN ASSUMES NO LIABILITY FOR ANY ERRORS, INACCURACIES, OR OMISSIONS CONTAINED WITHIN SUPPLEMENTAL INFORMATION PROVIDED BY THIRD PARTY CONSULTANTS. 1.BOUNDARY & TOPOGRAPHIC SURVEY PERFORMED BY: ANDERSON ENGINEERING ADDRESS: 13605 1ST AVE N, SUITE 100 PLYMOUTH, MN 55441 PHONE: 763-412-4000 2.CONSTRUCTION TESTING TEST REPORTS REQUIRED FOR CLOSE OUT INCLUDE, BUT ARE NOT LIMITED TO: ·DENSITY TEST REPORTS ·BACTERIOLOGICAL TESTS OF WATER SYSTEM ·PRESSURE TEST OF WATER/SEWER ·LEAK TESTS ON SEWER SYSTEM AND GREASE TRAPS ·ANY OTHER TESTING REQUIRED BY THE AGENCY/MUNICIPALITY PR E P A R E D F O R GE N E R A L N O T E S C100 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E 61 Item 5. 62 Item 5. SS S S S S S SS S S S S S ST ST S ST ST ST ST ST ST HH HH E ST 4 7 T H A V E N U E N E C E N T R A L A V E N U E N E G R A N D A V E N U E N E REMOVE CONCRETE PIERS & I-BEAMS PROTECT EXISTING STORM SEWER PROTECT EXISTING STORM SEWER SAWCUT CONCRETE SIDEWALK AND C&G SAWCUT CONCRETE SIDEWALK AND C&G SAWCUT AND REMOVE BITUMINOUS PAVEMENT AS NEEDED FOR DRIVEWAYS AND CURB INSTALLATION REMOVE C&G PROTECT EXISTING SANITARY SEWER REMOVE GRAVEL TRAIL PROTECT EXISTING UNDERGROUND POWER PROTECT EXISTING STORM SEWER 30' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 10' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 40' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 10' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 30' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION EXISTING PROPERTY LINE PROPOSED PROPERTY LINE PROTECT EXISTING LIGHT POLE PROTECT EXISTING STORM SEWER ASSUMED PREVIOUSLY REMOVED STORM INFRASTRUCTURE, CONTRACTOR TO FIELD VERIFY AND COORDINATE WITH ENGINEER IF STILL IN PLACE. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 2 - D E M O P L A N . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 3 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N PR E P A R E D F O R SI T E D E M O L I T I O N PL A N C200 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 REMOVE BITUMINOUS SURFACE REMOVE CONCRETE SURFACE REMOVE BUILDING REMOVE TREE REMOVE CONCRETE CURB & GUTTER PROPERTY LINE CLEARING & GRUBBING LEGEND FULL DEPTH SAWCUT 1.THE CONTRACTOR IS RESPONSIBLE FOR THE DEMOLITION, REMOVAL, AND DISPOSAL (IN A LOCATION APPROVED BY ALL GOVERNING AUTHORITIES) OF ALL STRUCTURES, PADS, WALLS, FLUMES, FOUNDATIONS, PARKING, DRIVES, DRAINAGE STRUCTURES, UTILITIES, ETC. SUCH THAT THE IMPROVEMENTS ON THE PLANS CAN BE CONSTRUCTED. FACILITIES TO BE REMOVED SHALL BE UNDERCUT TO SUITABLE MATERIAL AND BROUGHT TO GRADE WITH SUITABLE COMPACTED FILL MATERIAL PER THE PROJECT DOCUMENTS. 2.THE CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL DEBRIS FROM THE SITE AND DISPOSING OF THE DEBRIS IN A LAWFUL MANNER AND IN ACCORDANCE WITH LOCAL AND STATE REGULATIONS. THE CONTRACTOR SHALL OBTAIN ANY REQUIRED PERMITS FOR DEMOLITION AND DISPOSAL FROM THE APPROPRIATE LOCAL AND STATE AGENCIES. CONTRACTOR SHALL PROVIDE COPIES OF THE PERMIT AND RECEIPTS OF DISPOSAL OF MATERIALS TO THE OWNER AND OWNERS REPRESENTATIVE, INCLUDING THE TYPE OF DEBRIS AND LOCATION WHERE IT WAS DISPOSED. 3.THE CONTRACTOR SHALL MAINTAIN UTILITY SERVICES TO ADJACENT PROPERTIES AT ALL TIMES. UTILITY SERVICES SHALL NOT BE INTERRUPTED WITHOUT APPROVAL FROM THE CONSTRUCTION MANAGER AND COORDINATION WITH THE ADJACENT PROPERTIES AND/OR THE CITY. 4.THE CONTRACTOR SHALL COORDINATE WITH RESPECTIVE UTILITY COMPANIES PRIOR TO THE REMOVAL AND/OR RELOCATION OF UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY CONCERNING PORTIONS OF WORK WHICH MAY BE PERFORMED BY THE UTILITY COMPANY'S FORCES AND ANY FEES WHICH ARE TO BE PAID TO THE UTILITY COMPANY FOR THEIR SERVICES. THE CONTRACTOR IS RESPONSIBLE FOR PAYING ALL FEES AND CHARGES. 5.THE LOCATIONS OF EXISTING UTILITIES SHOWN ON THE PLAN HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THE START OF ANY DEMOLITION ACTIVITY, THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANIES TO PROVIDE LOCATIONS OF EXISTING UTILITIES WITHIN PROPOSED WORK AREA. 6.EXISTING SEWERS, PIPING AND UTILITIES SHOWN ARE BASED ON AVAILABLE RECORD PLAN DATA AND/OR FIELD UTILITY MARKINGS AND ARE NOT TO BE INTERPRETED AS THE EXACT LOCATION. ADDITIONAL UNMARKED OBSTACLES MAY EXIST ON THE SITE. VERIFY EXISTING CONDITIONS AND PROCEED WITH CAUTION AROUND ANY ANTICIPATED UNDERGROUND FEATURES. GIVE NOTICE TO AFFECTED UTILITY COMPANIES REGARDING REMOVAL OF SERVICE LINES AND CAP ANY ABANDONED LINES BEFORE PRECEDING WITH THE PROPOSED WORK. 7.ELECTRICAL, TELEPHONE, CABLE, WATER, FIBER OPTIC, AND/OR GAS LINES NEEDING TO BE REMOVED OR RELOCATED SHALL BE COORDINATED WITH THE AFFECTED UTILITY COMPANY. ADEQUATE TIME SHALL BE PROVIDED FOR RELOCATION AND CLOSE COORDINATION WITH THE UTILITY COMPANY IS NECESSARY TO PROVIDE A SMOOTH TRANSITION IN UTILITY SERVICE. CONTRACTOR SHALL PAY CLOSE ATTENTION TO EXISTING UTILITIES WITHIN ANY ROAD RIGHT-OF-WAY DURING CONSTRUCTION. 8.CONTRACTOR MUST PROTECT THE PUBLIC AT ALL TIMES WITH FENCING, BARRICADES, ENCLOSURES, ETC. (AND OTHER APPROPRIATE BEST MANAGEMENT PRACTICES) AS APPROVED BY THE CONSTRUCTION MANAGER. MAINTENANCE OF TRAFFIC CONTROL SHALL BE COORDINATED IN ACCORDANCE WITH THE CITY, COUNTY, AND STATE DOT AS NECESSARY. 9.CONTRACTOR SHALL MAINTAIN ACCESS TO ADJACENT PROPERTIES DURING CONSTRUCTION, AND SHALL NOTIFY ADJACENT PROPERTY OWNERS IF ACCESS WILL BE INTERRUPTED OR ALTERED AT ANY TIME DURING CONSTRUCTION. 10.PRIOR TO THE START OF DEMOLITION, INSTALL EROSION CONTROL BMP'S IN ACCORDANCE WITH THE EROSION & SEDIMENT CONTROL PLANS / SWPPP. 11.CONTRACTOR MAY LIMIT SAW-CUT AND PAVEMENT REMOVAL TO ONLY THOSE AREAS WHERE IT IS REQUIRED AS SHOWN ON THESE CONSTRUCTION PLANS BUT IF ANY DAMAGE IS INCURRED ON ANY OF THE SURROUNDING PAVEMENT OR CURB, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ITS REMOVAL AND REPAIR. 12.THE CONTRACTOR SHALL COORDINATE WATER MAIN WORK WITH THE CITY WATER AND FIRE DEPARTMENTS TO ENSURE ADEQUATE FIRE PROTECTION IS CONSTANTLY AVAILABLE TO THE SITE AND SURROUNDING PROPERTIES THROUGH ALL PHASES OF CONSTRUCTION. CONTRACTOR WILL BE RESPONSIBLE FOR ARRANGING/PROVIDING ANY REQUIRED WATER MAIN SHUT OFFS WITH THE CITY. ANY COSTS ASSOCIATED WITH WATER MAIN SHUT OFFS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR AND NO EXTRA COMPENSATION WILL BE PROVIDED. 13.IN THE EVENT A WELL IS FOUND, THE CONTRACTOR SHALL CONTACT THE ENGINEER AND OWNER IMMEDIATELY. ALL WELLS SHALL BE SEALED BY A LICENSED WELL CONTRACTOR IN ACCORDANCE WITH STATE REQUIREMENTS. 14.IN THE EVENT THAT UNKNOWN CONTAINERS OR TANKS ARE ENCOUNTERED, THE CONTRACTOR SHALL CONTACT THE OWNER AND/OR OWNERS REPRESENTATIVE IMMEDIATELY. ALL CONTAINERS SHALL BE DISPOSED OF AT A PERMITTED LANDFILL PER THE PROJECT DOCUMENTS. 15.CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY EXISTING DRAINTILE IS ENCOUNTERED ON SITE; ACTIVE DRAINTILE SHALL NOT BE REMOVED WITHOUT APPROVAL FROM THE ENGINEER. 16.IF CONTAMINATED MATERIAL IS ENCOUNTERED ON THE PROJECT SITE, THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE OWNER AND ENGINEER IMMEDIATELY. DEMOLITION PLAN NOTES Know what'sbelow. before you dig.Call NO R T H LIMITS OF CONSTRUCTION EXISTING OVERHEAD POWER LINE EXISTING CHAINLINK FENCE EXISTING J-BARRIER EXISTING RETAINING WALL EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATERMAIN EXISTING GAS MAIN EXISTING UNDERGROUND TELEPHONE EXISTING UNDERGROUND CABLE EXISTING CONTOUR928 EXISTING SIGN EXISTING STORM MANHOLE EXISTING STORM CATCHBASIN EXISTING GATE VALVE EXISTING HYDRANT EXISTING GUY WIRE EXISTING POWER POLE EXISTING LIGHT POLE EXISTING TREE EXISTING CURB & GUTTER D 0 GRAPHIC SCALE IN FEET 20 10 20 40 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E 63 Item 5. ST ST ST ST ST ST ST ST ST 4 7 T H A V E N U E N E C E N T R A L A V E N U E N E G R A N D A V E N U E N E 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 941 942 943 944 945 9 4 6 9 4 7 9 3 4 93 5 93 6 93 7 93 8 939 9 3 5 9 3 6 9 3 7 93 8 941 942 943 944 943 942 941 9 4 1 9 4 2 9 4 3 9 4 4 9 4 5 936 937 938 9 3 3 93 2 933 934 935 93 6 937 938 939 940 941942 943944 945 94 6 94 7 94 8 94 9 95 0 95 1 940 94 0 94 1 9 4 2 939 939 93 8 939 937 936 9 3 1 9 3 2 9 3 3 94 0 2 4 . 2 % 3 . 0 % 3 . 9 % 20 . 6 % 28. 2 % 18.2% 1.1% 4.4 % 14 . 8 % 12.9 % 6. 8 % 22 . 7 % 3.9% 17 . 8 % 36 . 5 % 2.7 % 5. 2 % 31 . 4 % 34 . 7 % TEMPORARY DIVERSION DITCH RUN AT 0.5% MIN. CONCRETE WASHOUT SEDIMENT TRAP BOTTOM: 936.50 20 . 0 ' 50.0' 25.0' 20 . 0 ' EXISTING PROPERTY LINE PROPOSED PROPERTY LINE TEMPORARY EARTHWORK STOCKPILING AREA 8' x 8' DEWATERING SEDIMENT BAG RIPRAP 1.INSTALL PERIMETER EROSION CONTROL (I.E. SILT FENCE) AND INLET PROTECTION AT EXISTING STORMWATER INLETS. 2.CONSTRUCT STABILIZED CONSTRUCTION ENTRANCE AND CONCRETE WASHOUT 3.PREPARE TEMPORARY PARKING AND STORAGE AREA. 4.CONSTRUCT AND STABILIZE DIVERSIONS AND TEMPORARY SEDIMENT TRAPS. 5.CLEAR AND GRUB THE SITE. 6.BEGIN MASS SITE GRADING AND ROUGH GRADE SITE SUFFICIENTLY TO ESTABLISH PROPOSED DRAINAGE PATTERNS. 7.START CONSTRUCTION OF THE BUILDING PAD AND STRUCTURES. 8.TEMPORARILY SEED, THROUGHOUT CONSTRUCTION, DISTURBED AREAS THAT WILL BE INACTIVE FOR 14 DAYS OR MORE OR AS REQUIRED BY THE NPDES AND/OR CITY GRADING PERMIT(S). NOTE: THE SEQUENCE OF CONSTRUCTION IS INTENDED TO CONVEY THE GENERAL CONCEPTS OF THE EROSION CONTROL DESIGN AND SHOULD NOT BE RELIED UPON FOR CONSTRUCTION PURPOSES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETAILED PHASING AND CONSTRUCTION SEQUENCING NECESSARY TO CONSTRUCT THE PROPOSED IMPROVEMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING IMMEDIATELY, PRIOR TO AND/OR DURING CONSTRUCTION IF ANY ADDITIONAL INFORMATION ON THE CONSTRUCTION SEQUENCE IS NECESSARY. PHASE 1 SEQUENCE OF CONSTRUCTION ROCK ENTRANCE INLET PROTECTION SILT FENCE LIMITS OF DISTURBANCE BIOROLL LEGEND EROSION CONTROL BLANKET AREA SUMMARY TOTAL PROPERTY AREA 1.23 AC / 53,589 SF EXISTING IMPERVIOUS AREA 0.00 AC / 0.0% EXISTING PERVIOUS AREA 1.23 AC / 53,589 SF / 100% PROPOSED IMPERVIOUS AREA 0.78 AC / 33,846 SF / 63% PROPOSED PERVIOUS AREA 0.45 AC / 19,503 SF / 37% TOTAL DISTURBED AREA 1.18 AC / 51,762 SF PHASE I BMP QUANTITIES SILT FENCE ±518 LF INLET PROTECTION 9 EA ROCK CONSTRUCTION ENTRANCE 1 EA BIO ROLL 237 LF Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 3 - E R O S P H 1 P L A N . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 4 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N Know what'sbelow. before you dig.Call NO R T H DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 PR E P A R E D F O R ER O S I O N A N D SE D I M E N T CO N T R O L P L A N - PH A S E 1 C300 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN THE CONTRACTOR MUST UPDATE THE SWPPP BY NOTING ON THE SITE MAPS IN THE JOB SITE BINDER TO REFLECT THE PROGRESS OF CONSTRUCTION ACTIVITIES AND GENERAL CHANGES TO THE PROJECT SITE FOR THE DURATION OF LAND DISTURBING ACTIVITIES. AT A MINIMUM, UPDATES SHALL BE MADE DAILY TO TRACK CONSTRUCTION PROGRESS DESCRIBED IN THE SEQUENCE OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR NOTING THE LOCATION OF THE JOB SITE TRAILER, TEMPORARY PARKING & LAYDOWN AREAS, PORTA-POTTY, WHEEL WASH, CONCRETE WASHOUT, FUEL & MATERIAL STORAGE, SOLID WASTE CONTAINERS, AND OTHER CONSTRUCTION RELATED FACILITIES THAT MAY IMPACT STORMWATER RUNOFF. SWPPP UPDATES & AMENDMENTS 0 GRAPHIC SCALE IN FEET 20 10 20 40 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E 1.THE STORM WATER POLLUTION PREVENTION PLAN ("SWPPP") IS COMPRISED OF THE EROSION CONTROL PLAN, THE STANDARD DETAILS, THE PLAN NARRATIVE, ATTACHMENTS INCLUDED IN THE SPECIFICATIONS OF THE SWPPP, PLUS THE PERMIT AND ALL SUBSEQUENT REPORTS AND RELATED DOCUMENTS. 2.ALL CONTRACTORS AND SUBCONTRACTORS INVOLVED WITH LAND DISTURBING ACTIVITIES SHALL OBTAIN A COPY OF THE SWPPP AND NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT, AND BECOME FAMILIAR WITH THEIR CONTENTS. 3.BEST MANAGEMENT PRACTICES (BMP'S) AND CONTROLS SHALL CONFORM TO FEDERAL, STATE AND LOCAL REQUIREMENTS, AS APPLICABLE. THE CONTRACTOR SHALL IMPLEMENT ADDITIONAL CONTROLS AS DIRECTED BY THE PERMITTING AGENCY, ENGINEER OR OWNER. 4.SITE ENTRY AND EXIT LOCATIONS SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT THE TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC ROADWAYS. SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO A PUBLIC ROADWAY FROM THE CONSTRUCTION SITE MUST BE REMOVED AS SOON AS PRACTICABLE. WHEN WASHING IS REQUIRED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO A PUBLIC ROADWAY, IT SHALL BE DONE IN AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN. ANY FINES IMPOSED FOR DISCHARGING SEDIMENT ONTO A PUBLIC RIGHT OF WAY SHALL BE PAID BY THE CONTRACTOR. 5.TEMPORARY SEEDING OR OTHER APPROVED METHODS OF STABILIZATION SHALL BE INITIATED WITHIN 7 DAYS OF THE LAST DISTURBANCE ON ANY AREA OF THE SITE. 6.THE CONTRACTOR SHALL MINIMIZE LAND DISTURBANCE AND CLEARING TO THE MAXIMUM EXTENT PRACTICAL OR AS REQUIRED BY THE GENERAL PERMIT. 7.CONTRACTOR SHALL DENOTE ON THE PLAN THE TEMPORARY PARKING AND STORAGE AREA WHICH SHALL ALSO BE USED AS THE EQUIPMENT MAINTENANCE AND CLEANING AREA, EMPLOYEE PARKING AREA, AND AREA FOR LOCATING PORTABLE FACILITIES, OFFICE TRAILERS, AND TOILET FACILITIES. 8.ALL WASH WATER FROM THE CONSTRUCTION SITE (CONCRETE TRUCKS, VEHICLE CLEANING, EQUIPMENT CLEANING, ETC.) SHALL BE DETAINED AND PROPERLY TREATED BEFORE DISPOSAL. 9.SUFFICIENT OIL AND GREASE ABSORBING MATERIALS AND FLOTATION BOOMS SHALL BE MAINTAINED ON SITE OR READILY AVAILABLE TO CONTAIN AND CLEAN-UP FUEL OR CHEMICAL SPILLS AND LEAKS. 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL ON SITE. THE USE OF MOTOR OILS AND OTHER PETROLEUM BASED OR TOXIC LIQUIDS FOR DUST SUPPRESSION OPERATIONS IS PROHIBITED. 11.RUBBISH, TRASH, GARBAGE, LITTER, OR OTHER SUCH MATERIALS SHALL BE DEPOSITED INTO SEALED CONTAINERS. MATERIALS SHALL BE PREVENTED FROM LEAVING THE PREMISES THROUGH THE ACTION OF WIND OR STORM WATER DISCHARGE INTO DRAINAGE DITCHES OR WATERS OF THE STATE. 12.STAGING AREAS, STOCKPILES, SPOILS, ETC. SHALL BE LOCATED OUTSIDE OF DRAINAGE WAYS SUCH THAT STORM WATER RUNOFF WILL NOT BE ADVERSELY AFFECTED. PROVIDE STABILIZATION MEASURES SUCH AS PERIMETER EROSION CONTROL BMP'S, SEEDING, OR OTHER COVERING AS NECESSARY TO PREVENT EROSION. 13.CONTRACTOR SHALL BE RESPONSIBLE FOR RE-ESTABLISHING ANY EROSION CONTROL BMP DISTURBED DURING CONSTRUCTION OPERATIONS. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DEFICIENCIES IN THE ESTABLISHED EROSION CONTROL MEASURES THAT MAY LEAD TO UNAUTHORIZED DISCHARGE OF STORM WATER POLLUTANTS. UNAUTHORIZED POLLUTANTS INCLUDE (BUT ARE NOT LIMITED TO) EXCESS CONCRETE DUMPING, CONCRETE RESIDUE, PAINTS, SOLVENTS, GREASES, FUELS, LUBRICANT OILS, PESTICIDES, AND SOLID WASTE MATERIALS. 14.EROSION CONTROL BMP'S SHOWN ON THESE PLANS SHALL BE INSTALLED PRIOR TO THE START OF LAND-DISTURBING ACTIVITIES ON THE PROJECT, AND INITIATED AS SOON AS PRACTICABLE. 15.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR COMPLYING WITH THE REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION, AND SHALL MAINTAIN COMPLIANCE WITH APPLICABLE LAWS AND REGULATIONS FOR THE DURATION OF CONSTRUCTION. 16.THE CONTRACTOR SHALL FIELD ADJUST AND/OR PROVIDE ADDITIONAL EROSION CONTROL BMP'S AS NEEDED TO PREVENT EROSION AND OFF-SITE SEDIMENT DISCHARGE FROM THE CONSTRUCTION SITE. LOG AND RECORD ANY ADJUSTMENTS AND DEVIATIONS FROM THE APPROVED EROSION CONTROL PLANS WITHIN THE SWPPP DOCUMENTS STORED IN THE JOB SITE TRAILER. 17.CONTRACTOR IS RESPONSIBLE FOR PROVIDING STREET SWEEPING ON ADJACENT STREETS TO REMOVE SEDIMENT TRACKED FROM THE SITE OR FROM CONSTRUCTION STORMWATER RUNOFF PER THE REQUIREMENTS OF THE CONSTRUCTION STORMWATER PERMIT. 18.EXCESS WATER FROM SEDIMENT TRAP IS TO BE PUMPED FROM THE SEDIMENT TRAP INTO THE DEWATERING BAG. THE DEWATERING BAG SHALL BE PLACED ON AN AGGREGATE PAD THAT IS LOCATED WITHIN A VEGETATED AREA (IF POSSIBLE). RIPRAP OR OTHER APPROVED ENERGY DISSIPATION METHODS IN THE MINNESOTA STORMWATER MANUAL SHALL BE USED IN THE FLOW PATH FROM THE DEWATERING BAG BEFORE IT DISCHARGES INTO THE STORM SEWER SYSTEM. EROSION CONTROL PLAN NOTES 64 Item 5. 9 3 1 9 3 2 9 3 3 934 9 3 4 934 935 9 3 5 935 936 9 3 6 936 9 3 7 937 937 9 3 8 938 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 938 939 94 0 940 941 94 1 942 94 2 94 3 943 944 94 4 945 945 9 4 1 94 2 94 3 944 945 946 947 948 94 9 95 0 951 9 5 2 952 9 5 3 953 9 5 4 954 9 5 5 955 935936937938939940 SS S S S S S SS S S S S S ST ST S ST ST ST ST ST ST ST CAR WASH BUILDING 6,200 S.F. 947.00 FFE 4 7 T H A V E N U E N E C E N T R A L A V E N U E N E G R A N D A V E N U E N E 20 . 0 ' 50.0' 946 947 948 949 950 951 952 953 9 4 7 948 949 950 951 952 953 954 94 7 94 8 94 1 94 2 94 3 94 4 94 5 94 6 94 7 94 8 94 9 943 944 945 943 944 945 942 9 4 9 94 6 9 4 0 9 4 1 94 2 94 3 9 4 4 9 4 5 9 4 6 9 4 7 955 CONCRETE WASHOUT D CO CO D D 7.95 % 1 . 2 4 % 2. 6 3 % 1 . 2 3 % 2 . 0 2 % 9. 8 3 % 7.0 6 % 2. 1 1 % 3 . 5 5 % 2 . 6 8 % 14.98 % 4.9 6 % 3. 9 2 % 2.82% 4.50 % 12 . 0 0 % 22 . 2 6 % 3: 1 4: 1 4: 1 3: 1 3:1 ?? ? ?? ? 1: 1 3: 1 5: 1 PROPOSED PROPERTY LINE 3: 1 CO PR E P A R E D F O R ER O S I O N A N D SE D I M E N T CO N T R O L P L A N - PH A S E 2 C301 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 1.TEMPORARILY SEED, THROUGHOUT CONSTRUCTION, DENUDED AREAS THAT WILL BE INACTIVE FOR 14 DAYS OR MORE. 2.CONSTRUCT UNDERGROUND SITE UTILITIES AND STORM SEWER, INCLUDING UNDERGROUND STORMWATER MANAGEMENT SYSTEM. 3.INSTALL APPROPRIATE INLET PROTECTION AT ANY NEW STORM SEWER STRUCTURES AS EACH STRUCTURE IS CONSTRUCTED. 4.COMPLETE SITE GRADING AND PERMANENTLY STABILIZE AREAS TO BE VEGETATED AS THEY ARE BROUGHT TO FINAL GRADE. 5.PLACE PAVEMENT BASE MATERIAL AND INSTALL SUBDRAINAGE SYSTEM. 6.CONSTRUCT PAVEMENTS, CURB & GUTTER, AND SIDEWALKS. 7.AS APPROPRIATE, REPLACE & MAINTAIN INLET PROTECTION DEVICES WITHIN PAVED AREAS AS WORK PROGRESSES. 8.COMPLETE FINAL GRADING AND INSTALL OF PERMANENT STABILIZATION (SEEDING, SODDING, ETC.) WITHIN LANDSCAPED AREAS. 9.WHEN THE SITE HAS ACHIEVED FINAL STABILIZATION AS DEFINED BY THE APPLICABLE EROSION CONTROL PERMITS, REMOVE ALL REMAINING TEMPORARY EROSION & SEDIMENT CONTROL BMP'S AND RE-STABILIZE ANY AREAS DISTURBED BY THE REMOVAL. NOTE: THE SEQUENCE OF CONSTRUCTION IS INTENDED TO CONVEY THE GENERAL CONCEPTS OF THE EROSION CONTROL DESIGN AND SHOULD NOT BE RELIED UPON FOR CONSTRUCTION PURPOSES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETAILED PHASING AND CONSTRUCTION SEQUENCING NECESSARY TO CONSTRUCT THE PROPOSED IMPROVEMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING IMMEDIATELY, PRIOR TO AND/OR DURING CONSTRUCTION IF ANY ADDITIONAL INFORMATION ON THE CONSTRUCTION SEQUENCE IS NECESSARY. PHASE 2 SEQUENCE OF CONSTRUCTION ROCK ENTRANCE INLET PROTECTION SILT FENCE LIMITS OF DISTURBANCE SAFETY FENCE BIOROLL LEGEND EROSION CONTROL BLANKET 1.THE STORM WATER POLLUTION PREVENTION PLAN ("SWPPP") IS COMPRISED OF THE EROSION CONTROL PLAN, THE STANDARD DETAILS, THE PLAN NARRATIVE, ATTACHMENTS INCLUDED IN THE SPECIFICATIONS OF THE SWPPP, PLUS THE PERMIT AND ALL SUBSEQUENT REPORTS AND RELATED DOCUMENTS. 2.ALL CONTRACTORS AND SUBCONTRACTORS INVOLVED WITH LAND DISTURBING ACTIVITIES SHALL OBTAIN A COPY OF THE SWPPP AND NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT, AND BECOME FAMILIAR WITH THEIR CONTENTS. 3.BEST MANAGEMENT PRACTICES (BMP'S) AND CONTROLS SHALL CONFORM TO FEDERAL, STATE AND LOCAL REQUIREMENTS, AS APPLICABLE. THE CONTRACTOR SHALL IMPLEMENT ADDITIONAL CONTROLS AS DIRECTED BY THE PERMITTING AGENCY, ENGINEER OR OWNER. 4.SITE ENTRY AND EXIT LOCATIONS SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT THE TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC ROADWAYS. SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO A PUBLIC ROADWAY FROM THE CONSTRUCTION SITE MUST BE REMOVED AS SOON AS PRACTICABLE. WHEN WASHING IS REQUIRED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO A PUBLIC ROADWAY, IT SHALL BE DONE IN AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN. ANY FINES IMPOSED FOR DISCHARGING SEDIMENT ONTO A PUBLIC RIGHT OF WAY SHALL BE PAID BY THE CONTRACTOR. 5.TEMPORARY SEEDING OR OTHER APPROVED METHODS OF STABILIZATION SHALL BE INITIATED WITHIN 7 DAYS OF THE LAST DISTURBANCE ON ANY AREA OF THE SITE. 6.THE CONTRACTOR SHALL MINIMIZE LAND DISTURBANCE AND CLEARING TO THE MAXIMUM EXTENT PRACTICAL OR AS REQUIRED BY THE GENERAL PERMIT. 7.CONTRACTOR SHALL DENOTE ON THE PLAN THE TEMPORARY PARKING AND STORAGE AREA WHICH SHALL ALSO BE USED AS THE EQUIPMENT MAINTENANCE AND CLEANING AREA, EMPLOYEE PARKING AREA, AND AREA FOR LOCATING PORTABLE FACILITIES, OFFICE TRAILERS, AND TOILET FACILITIES. 8.ALL WASH WATER FROM THE CONSTRUCTION SITE (CONCRETE TRUCKS, VEHICLE CLEANING, EQUIPMENT CLEANING, ETC.) SHALL BE DETAINED AND PROPERLY TREATED BEFORE DISPOSAL. 9.SUFFICIENT OIL AND GREASE ABSORBING MATERIALS AND FLOTATION BOOMS SHALL BE MAINTAINED ON SITE OR READILY AVAILABLE TO CONTAIN AND CLEAN-UP FUEL OR CHEMICAL SPILLS AND LEAKS. 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL ON SITE. THE USE OF MOTOR OILS AND OTHER PETROLEUM BASED OR TOXIC LIQUIDS FOR DUST SUPPRESSION OPERATIONS IS PROHIBITED. 11.RUBBISH, TRASH, GARBAGE, LITTER, OR OTHER SUCH MATERIALS SHALL BE DEPOSITED INTO SEALED CONTAINERS. MATERIALS SHALL BE PREVENTED FROM LEAVING THE PREMISES THROUGH THE ACTION OF WIND OR STORM WATER DISCHARGE INTO DRAINAGE DITCHES OR WATERS OF THE STATE. 12.STAGING AREAS, STOCKPILES, SPOILS, ETC. SHALL BE LOCATED OUTSIDE OF DRAINAGE WAYS SUCH THAT STORM WATER RUNOFF WILL NOT BE ADVERSELY AFFECTED. PROVIDE STABILIZATION MEASURES SUCH AS PERIMETER EROSION CONTROL BMP'S, SEEDING, OR OTHER COVERING AS NECESSARY TO PREVENT EROSION. 13.CONTRACTOR SHALL BE RESPONSIBLE FOR RE-ESTABLISHING ANY EROSION CONTROL BMP DISTURBED DURING CONSTRUCTION OPERATIONS. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DEFICIENCIES IN THE ESTABLISHED EROSION CONTROL MEASURES THAT MAY LEAD TO UNAUTHORIZED DISCHARGE OF STORM WATER POLLUTANTS. UNAUTHORIZED POLLUTANTS INCLUDE (BUT ARE NOT LIMITED TO) EXCESS CONCRETE DUMPING, CONCRETE RESIDUE, PAINTS, SOLVENTS, GREASES, FUELS, LUBRICANT OILS, PESTICIDES, AND SOLID WASTE MATERIALS. 14.EROSION CONTROL BMP'S SHOWN ON THESE PLANS SHALL BE INSTALLED PRIOR TO THE START OF LAND-DISTURBING ACTIVITIES ON THE PROJECT, AND INITIATED AS SOON AS PRACTICABLE. 15.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR COMPLYING WITH THE REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION, AND SHALL MAINTAIN COMPLIANCE WITH APPLICABLE LAWS AND REGULATIONS FOR THE DURATION OF CONSTRUCTION. 16.THE CONTRACTOR SHALL FIELD ADJUST AND/OR PROVIDE ADDITIONAL EROSION CONTROL BMP'S AS NEEDED TO PREVENT EROSION AND OFF-SITE SEDIMENT DISCHARGE FROM THE CONSTRUCTION SITE. LOG AND RECORD ANY ADJUSTMENTS AND DEVIATIONS FROM THE APPROVED EROSION CONTROL PLANS WITHIN THE SWPPP DOCUMENTS STORED IN THE JOB SITE TRAILER. 17.CONTRACTOR IS RESPONSIBLE FOR PROVIDING STREET SWEEPING ON ADJACENT STREETS TO REMOVE SEDIMENT TRACKED FROM THE SITE OR FROM CONSTRUCTION STORMWATER RUNOFF PER THE REQUIREMENTS OF THE CONSTRUCTION STORMWATER PERMIT. 18.EXCESS WATER FROM SEDIMENT TRAP IS TO BE PUMPED FROM THE SEDIMENT TRAP INTO THE DEWATERING BAG. THE DEWATERING BAG SHALL BE PLACED ON AN AGGREGATE PAD THAT IS LOCATED WITHIN A VEGETATED AREA (IF POSSIBLE). RIPRAP OR OTHER APPROVED ENERGY DISSIPATION METHODS IN THE MINNESOTA STORMWATER MANUAL SHALL BE USED IN THE FLOW PATH FROM THE DEWATERING BAG BEFORE IT DISCHARGES INTO THE STORM SEWER SYSTEM. EROSION CONTROL PLAN NOTES Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 3 - E R O S P H 2 P L A N . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 4 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N Know what'sbelow. before you dig.Call NO R T H PHASE 2 BMP QUANTITIES SILT FENCE ±518 LF INLET PROTECTION 9 EA ROCK CONSTRUCTION ENTRANCE 1 EA BIO ROLL 186 LF EROSION CONTROL BLANKET ±12,443 SF THE CONTRACTOR MUST UPDATE THE SWPPP BY NOTING ON THE SITE MAPS IN THE JOB SITE BINDER TO REFLECT THE PROGRESS OF CONSTRUCTION ACTIVITIES AND GENERAL CHANGES TO THE PROJECT SITE FOR THE DURATION OF LAND DISTURBING ACTIVITIES. AT A MINIMUM, UPDATES SHALL BE MADE DAILY TO TRACK CONSTRUCTION PROGRESS DESCRIBED IN THE SEQUENCE OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR NOTING THE LOCATION OF THE JOB SITE TRAILER, TEMPORARY PARKING & LAYDOWN AREAS, PORTA-POTTY, WHEEL WASH, CONCRETE WASHOUT, FUEL & MATERIAL STORAGE, SOLID WASTE CONTAINERS, AND OTHER CONSTRUCTION RELATED FACILITIES THAT MAY IMPACT STORMWATER RUNOFF. SWPPP UPDATES & AMENDMENTS 0 GRAPHIC SCALE IN FEET 20 10 20 40 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E AREA SUMMARY TOTAL PROPERTY AREA 1.23 AC / 53,589 SF EXISTING IMPERVIOUS AREA 0.00 AC / 0.0% EXISTING PERVIOUS AREA 1.23 AC / 53,589 SF / 100% PROPOSED IMPERVIOUS AREA 0.78 AC / 33,846 SF / 63% PROPOSED PERVIOUS AREA 0.45 AC / 19,503 SF / 37% TOTAL DISTURBED AREA 1.18 AC / 51,762 65 Item 5. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 3 - E R O S D E T A I L S . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 4 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E SCALE: NTS INLET PROTECTION2 NO SCALE EROSION CONTROL BLANKET6 BIO-ROLL BLANKET SYSTEM STRAW OR WOOD FIBER 6"-7''DIA. ROLL ENCLOSED IN PLASTIC OR POLYESTER NETTING 1POINT ''B'' 4''X4'' TRENCH BACKFILLED OVER EROSION CONTROL BLANKET (SPEC. 3885) CATEGORY 3 EROSION CONTROL BLANKET (SPEC. 3885) ( TYPE 3 SPEC. 3889 ) 12 ' M I N I M U M BL A N K E T S M U S T O V E R L A P B Y 4 ' ' 2''X2''X18'' LONG WOODEN STAKES AT 2' 0'' SPACING. DRIVE THROUGH NETTING AND FIBER ROLL. 8'', 11 GA. STAPLES SPACED 1'0" ON CENTER FLOW POINT ''A'' STEEL FENCE POSTS 7'-7" O.C. 30" 24" OVERLAP GEOTEXTILE FABRIC 6" AND FASTEN ENGINEERING FABRIC (MIRAFI ENVIRO-FENCE OR APPROVED EQUAL) WIRE MESH REINFORCEMENT BACKFILL BURY BOTTOM 6" OF FABRIC EXISTING GROUND NOTE: PAID FOR AS SILT FENCE-HEAVY DUTY CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL EROSION CONTROL MATERIALS FOLLOWING TURF ESTABLISHMENT HEAVY-DUTY EROSION CONTROL FENCE MIN. 6" (152 mm) OF 1" TO 2" (25 mm TO 51 mm) DIA ROCK. MNDOT STANDARD SPECIFICATION 3733 TYPE V PERMEABLE GEOTEXTILE FABRIC BENEATH ROCK 5 0 ' ( 1 5 . 2 4 m ) M I N I M U M HAR D S U R F A C E PUB L I C R O A D 24" (457 mm) MIN. HIGH CUT-OFF BERM TO MINIMIZE SILT RUNOFF FROM SITE. VARIES: FULL WIDTH OF EXISTING DRIVEWAY OPENING, ELSE 20' (6.10 m) MIN. WIDTH. FOAM CURB OPENING EXPANSION RESTRAINT SIDE VIEW INSTALLED INSTALLATION DETAIL R 1" REBAR FOR BAG REMOVAL FROM INLET (REBAR NOT INCLUDED) OPTIONAL OVERFLOW SILTSACK DUMP LOOPS (REBAR NOT INCLUDED)DEPTH = D LE N G T H = L WIDTH = W 1 3B 3A 4 5 2 4"- 6" 6" 6" 12" 3" 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. 2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" DEEP X 6" WIDE TRENCH WITH APPROXIMATELY 12" OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" APART ACROSS THE WIDTH OF THE BLANKET. 3. ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS PER MANUFACTURES RECOMMENDATION. 4. THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 4"-6" OVERLAP DEPENDING ON BLANKET TYPE. TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH THE SEAM STITCH ON THE PREVIOUSLY INSTALLED BLANKET. 5. CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3"OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12"APART ACROSS ENTIRE BLANKET WIDTH. 6. PLACE STAPLES/STAKES PER MANUFACTURE RECOMMENDATION FOR THE APPROPRIATE SLOPE BEING APPLIED. NOTES: 1. IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" MAY BE NECESSARY TO PROPERLY SECURE THE BLANKETS. 2. FOLLOW EROSION CONTROL TECHNOLOGY COUNCIL SPECIFICATION FOR PRODUCT SELECTION SCALE: NTS SILT FENCE3 TEMPORARY DIVERSION 3 1 3 1 3 1 DESIGN FLOW DEPTH 12" MIN. FREEBOARD DESIGN FLOW DEPTH W W W LON G I T U D I N A L S L O P E TYPICAL PARABOLIC DIVERSION TYPICAL TRAPEZOIDAL DIVERSION TYPICAL VEE-SHAPED DIVERSION NOTE 2 NOTE 1 NOTE 2 NOTE 1 NOTE 2 NOTE 1 DESIGN FLOW DEPTH CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) 12" MIN. FREEBOARD 12" MIN. FREEBOARD N.T.S. CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) NOTES: 1. REMOVE ANY EXISTING VEGETATION AND SCARIFY OR BENCH ADJACENT SOILS PRIOR TO PLACING BERM. 2. BERM MATERIALS MUST BE ADEQUATELY COMPACTED AND IMMEDIATELY STABILIZED. 3. DIVERSION DITCHES/BERMS MUST BE IMMEDIATELY STABILIZED TO PREVENT EROSION AND TRANSPORT OF SEDIMENT. SCALE: NTS DIVERSION DITCH1 SCALE: NTS CONSTRUCTION ENTRANCE4 SCALE: NTS BIOROLL5 PR E P A R E D F O R ER O S I O N A N D SE D I M E N T CO N T R O L D E T A I L S C302 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN 66 Item 5. A.SITE IS WITHIN THE BOUNDARY FOR HIGHLAND LAKE IMPAIRED. B.SITE IS WITHIN THE BOUNDARY FOR SULLIVAN LAKE IMPAIRED. DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 3 A - S W P P P . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 4 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N PROJECT DESCRIPTION 1.THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A CAR WASH FACILITY WITH A SECTION SET FOR CAR VACUUM CLEANERS. A.PROJECT OFFICE WALL SWPPP POSTINGS: THE FOLLOWING ITEMS MUST BE POSTED TOGETHER IN A SINGLE, ORGANIZED LOCATION ON A WALL INSIDE THE PROJECT OFFICE: 1) SWPPP SITE MAPS (ALL PHASES); 2) SWPPP DETAIL SHEETS; 3) MAP SHOWING LOCATION OF OFFSITE IMPORT OR EXPORT FACILITY; 4) REVISIONS TO DETAILS, SITE MAPS, OR SWPPP-RELATED RFIS; 5) SITE SWPPP BINDER; 6) SWCT PLACARD; 7) CURRENT OWNER STORMWATER COMPLIANCE TRAINING CERTIFICATES FOR SUPERINTENDENT(S) AND COMPLIANCE OFFICER(S); AND 8) CERTIFICATIONS AND/OR TRAINING CERTIFICATES REQUIRED TO PERFORM INSPECTIONS BY THE APPLICABLE CONSTRUCTION GENERAL PERMIT OR AUTHORITY HAVING JURISDICTION. B.PERMITTED PROJECT AREA: FOR PURPOSES OF THIS SWPPP AND ASSOCIATED STORMWATER PERMIT, 'PERMITTED PROJECT AREA' IS DEFINED AS ANY AND ALL AREAS WITHIN THE PROJECT LIMITS OF DISTURBANCE, AS SHOWN ON THE SWPPP SITE MAPS AND IDENTIFIED IN THE NOTICE OF INTENT TO THE AGENCY. ALL GROUND-DISTURBING AND CONSTRUCTION-RELATED ACTIVITIES (MATERIAL STORAGE, DUMPSTERS, PARKING AREAS, PROJECT OFFICE TRAILER, ETC.) MUST BE INCLUDED WITHIN THE PERMITTED PROJECT AREA LIMITS OF DISTURBANCE. ALL AREAS OUTSIDE THE PERMITTED PROJECT AREA (I.E., LIMITS OF DISTURBANCE) ACQUIRED FOR USE BY THE GC OR A SUBCONTRACTOR OF THE GC (BORROW SOURCES, DISPOSAL AREAS, ETC.) MUST BE MANAGED IN ACCORDANCE WITH THE NPDES PERMIT. THE CONTRACTOR IS REQUIRED TO LOCATE OFFICE TRAILERS AND MATERIAL STORAGE AREAS FOR THE PROJECT WITHIN THE LIMITS OF DISTURBANCE. THE CONTRACTOR MAY REQUEST USE OF OFF-SITE LOCATIONS FOR OFFICE TRAILERS OR NON-ERODIBLE MATERIAL STORAGE; HOWEVER, APPROVAL MUST BE OBTAINED FROM THE CONSTRUCTION MANAGER, AND THE CEC PRIOR TO THEIR USE. REQUESTS WILL BE REVIEWED ON A CASE BY CASE BASIS AND IF APPROVED, LIMITATIONS ON USE WILL BE PROVIDED BY THE CEC. C.SPECIAL PROJECT AREAS: THERE ARE NO SPECIAL PROJECTS, LOCATED BEYOND THE OWNER PERMITTED PROJECT AREA, REQUIRING INSPECTION AND MAINTENANCE ASSOCIATED WITH THIS CONSTRUCTION PROJECT. D.1 NON-STORMWATER DISCHARGES: THE GENERAL PERMIT FOR STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES PROHIBITS MOST NON-STORMWATER DISCHARGES DURING THE CONSTRUCTION PHASE. ALLOWABLE NON-STORMWATER DISCHARGES THAT OCCUR DURING CONSTRUCTION ON THIS PROJECT, ARE INCLUDED IN THE SECTION PART IV.D. OF THE GENERAL PERMIT. BEST MANAGEMENT PRACTICES (BMPS) MUST BE IMPLEMENTED FOR THE GENERAL PERMIT ALLOWABLE DISCHARGES FOR THE DURATION OF THE PERMIT. THE TECHNIQUES DESCRIBED IN THIS SWPPP FOCUS ON PROVIDING CONTROL OF POLLUTANT DISCHARGES WITH PRACTICAL APPROACHES THAT UTILIZE READILY AVAILABLE EXPERTISE, MATERIAL, AND EQUIPMENT. NON-STORMWATER COMPONENTS OF SITE DISCHARGES MUST BE UNCONTAMINATED NON-TURBID WATER. ALL NON-STORMWATER DISCHARGES MUST BE ROUTED TO A STORMWATER CONTROL PRIOR TO DISCHARGE. WATER USED FOR CONSTRUCTION WHICH DISCHARGES FROM THE SITE MUST ORIGINATE FROM A PUBLIC WATER SUPPLY OR PRIVATE WELL APPROVED BY THE STATE HEALTH DEPARTMENT. WATER USED FOR CONSTRUCTION THAT DOES NOT ORIGINATE FROM AN APPROVED PUBLIC SUPPLY MUST NOT DISCHARGE FROM THE SITE; IT CAN BE RETAINED IN RETENTION PONDS UNTIL IT INFILTRATES OR EVAPORATES. WHEN NON-STORMWATER IS DISCHARGED FROM THE SITE, IT MUST BE DONE IN A MANNER SUCH THAT IT DOES NOT CAUSE EROSION OF THE SOIL DURING DISCHARGE. D.2 POWER WASHING: PROCESS WATER SUCH AS POWER WASHING WATER AND CONCRETE CUTTING EFFLUENT, AMONG OTHERS, MUST BE COLLECTED FOR TREATMENT AND DISPOSAL. IT MUST NOT BE FLUSHED INTO THE SITE STORM DRAIN SYSTEM OR DISCHARGED OFF-SITE. D.DISCHARGE POINTS: ALL DISCHARGE POINTS MUST BE INSPECTED TO DETERMINE WHETHER EROSION AND SEDIMENTATION CONTROL MEASURES ARE EFFECTIVE IN PREVENTING DISCHARGE OF SEDIMENT FROM THE SITE AND/OR IMPACTS TO RECEIVING WATERS. SEDIMENT ACCUMULATION DOWNGRADIENT OF DISCHARGE LOCATIONS SHALL BE REPORTED AS A SEDIMENT DISCHARGE AND THE POTENTIAL UPSTREAM CAUSE SHALL BE INVESTIGATED TO PREVENT FUTURE OCCURRENCE. CONTACT THE CM AND CEC TO DETERMINE APPROPRIATE ACTION FOR CLEANUP OF DISCHARGED SEDIMENT THAT MAY BE OUTSIDE OF THE LIMITS OF DISTURBANCE. SEE SAMPLING AND MONITORING OF EFFLUENT PLAN (IF APPLICABLE). E.CONTRACTOR SHALL UTILIZE TYPICAL CONSTRUCTION METHODS TO PROMOTE GROWTH IN RESTORING WITH TOPSOIL. F.LOCAL RAINFALL INTENSITIES WERE CONSIDERED WHEN DEVELOPING BMP'S. G.FINAL VEGETATION OF THE SITE NEEDS TO BE AT 70% OF EXPECTED PERMANENT COVERAGE BEFORE THE NOTICE OF TERMINATION CAN BE SUBMITTED. GENERAL NOTES A.SUBCONTRACTOR SHALL IMPLEMENT BEST MANAGEMENT PRACTICES AS REQUIRED BY THIS STORM WATER POLLUTION PREVENTION PLAN. ADDITIONAL BEST MANAGEMENT PRACTICES SHALL BE IMPLEMENTED AS DICTATED BY CONDITIONS AT NO ADDITIONAL COST OF OWNER THROUGHOUT ALL PHASES OF CONSTRUCTION. B.BEST MANAGEMENT PRACTICES (BMP'S) AND CONTROLS SHALL CONFORM TO FEDERAL, STATE, OR LOCAL REQUIREMENTS OR MANUAL OF PRACTICE, AS APPLICABLE. CONTRACTOR SHALL IMPLEMENT ADDITIONAL CONTROLS AS DIRECTED BY PERMITTING AGENCY OR OWNER. C.SITE MAP MUST CLEARLY DELINEATE ALL STATE WATERS. PERMITS FOR ANY CONSTRUCTION ACTIVITY IMPACTING STATE WATERS OR REGULATED WETLANDS MUST BE MAINTAINED ON SITE AT ALL TIMES. D.SUBCONTRACTOR TO LIMIT DISTURBANCE OF SITE IN STRICT ACCORDANCE WITH SWPPP IMPLEMENTATION SEQUENCE, OR AS REQUIRED BY THE APPLICABLE GENERAL PERMIT. NO UNNECESSARY OR IMPROPERLY SEQUENCED CLEARING AND/OR GRADING SHALL BE PERMITTED. E.ALL DENUDED/BARE AREAS THAT WILL BE INACTIVE FOR 7 DAYS OR MORE, MUST BE STABILIZED IMMEDIATELY UPON COMPLETION OF MOST RECENT GRADING ACTIVITY, WITH THE USE OF FAST-GERMINATING ANNUAL GRASS/GRAIN VARIETIES, STRAW/HAY MULCH, WOOD CELLULOSE FIBERS, TACKIFIERS, NETTING AND/OR BLANKETS. COMPLETION MUST BE ACHIEVED WITHIN 7 DAYS. F.DISTURBED PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITY HAS PERMANENTLY STOPPED SHALL BE PERMANENTLY STABILIZED AS SHOWN ON THE PLANS. THESE AREAS SHALL BE SEEDED, SODDED, AND/OR VEGETATED IMMEDIATELY, AND COMPLETED NO LATER THAN 7 DAYS AFTER THE LAST CONSTRUCTION ACTIVITY OCCURRING IN THESE AREAS. REFER TO THE GRADING PLAN AND/OR LANDSCAPE PLAN. G.SLOPES SHALL BE LEFT IN A ROUGHENED CONDITION DURING THE GRADING PHASE TO REDUCE RUNOFF VELOCITIES AND EROSION. TEMPORARY AND/OR PERMANENT STABILIZATION SHALL BE APPLIED PER REQUIREMENTS IN THESE E&S CONTROL NOTES. H.DUE TO THE GRADE CHANGES DURING THE DEVELOPMENT OF THE PROJECT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING THE EROSION AND SEDIMENT CONTROL MEASURES (SILT FENCES, ETC.) TO PREVENT EROSION AND POLLUTANT DISCHARGE OFF-SITE. I.ALL MEASURES STATED ON THIS SITE MAP, AND IN THE STORM WATER POLLUTION PREVENTION PLAN, SHALL BE MAINTAINED IN FULLY FUNCTIONAL CONDITION UNTIL NO LONGER REQUIRED FOR A COMPLETED PHASE OF WORK OR FINAL STABILIZATION OF THE SITE. ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE CHECKED BY A QUALIFIED PERSON IN ACCORDANCE WITH THE CONTRACT DOCUMENTS OR THE APPLICABLE PERMIT, WHICHEVER IS MORE STRINGENT, AND REPAIRED IN ACCORDANCE WITH THE SITE PLANS. J.STORM WATER POLLUTANT CONTROL MEASURES INSTALLED DURING CONSTRUCTION, THAT WILL ALSO PROVIDE STORM WATER MANAGEMENT AFTER CONSTRUCTION, ARE INCLUDED IN THE CONTRACT DOCUMENTS. THE SITE-SPECIFIC POST CONSTRUCTION STORM WATER OPERATION AND MAINTENANCE (O&M) MANUAL IS INCLUDED IN THE CONTRACT DOCUMENTS. K.ALL PERMANENT CONTROLS AND SYSTEMS MUST BE INSTALLED AND FUNCTIONING AS DESIGNED AND FREE OF ACCUMULATED SEDIMENT AND DEBRIS DURING FINAL PROJECT INSPECTION AND APPROVAL. L.SILT FENCE OR FABRIC PLACED UNDER THE GRATE IS NOT AN APPROVED FORM OF INLET PROTECTION. EROSION AND SEDIMENT CONTROL NOTES ANY HAZARDOUS OR POTENTIALLY HAZARDOUS MATERIAL THAT IS BROUGHT ONTO THE CONSTRUCTION SITE SHALL BE HANDLED PROPERLY TO REDUCE THE POTENTIAL FOR STORMWATER POLLUTION. ALL MATERIALS USED ON THIS CONSTRUCTION SITE SHALL BE PROPERLY STORED, HANDLED, DISPENSED AND DISPOSED OF FOLLOWING ALL APPLICABLE LABEL DIRECTIONS. FLAMMABLE AND COMBUSTIBLE LIQUIDS SHALL BE STORED AND HANDLED ACCORDING TO APPLICABLE REGULATIONS, AND, AT A MINIMUM, ACCORDING TO 29 CFR 1926.152. ONLY APPROVED CONTAINERS AND PORTABLE TANKS SHALL BE USED FOR STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS. MATERIAL SAFETY DATA SHEETS (MSDS) INFORMATION SHALL BE KEPT ON SITE FOR ANY AND ALL APPLICABLE MATERIALS. HOWEVER, MSDS MAY ALSO BE ACCESSED VIA TELEPHONE OR OTHER ELECTRONIC MEANS OR APPARATUS. IN THE EVENT OF AN ACCIDENTAL SPILL, IMMEDIATE ACTION SHALL BE TAKEN BY THE SUBCONTRACTOR TO CONTAIN AND REMOVE THE SPILLED MATERIAL. THE SPILL SHALL BE REPORTED TO THE APPROPRIATE AGENCIES IN THE REQUIRED TIME FRAMES. AS REQUIRED UNDER THE PROVISIONS OF THE CLEAN WATER ACT, ANY SPILL OR DISCHARGE ENTERING WATERS OF THE UNITED STATES SHALL BE PROPERLY REPORTED. ALL HAZARDOUS MATERIALS, INCLUDING CONTAMINATED SOIL AND LIQUID CONCRETE WASTE, SHALL BE DISPOSED OF BY THE SUBCONTRACTOR IN THE MANNER SPECIFIED BY FEDERAL, STATE AND LOCAL REGULATIONS AND BY THE MANUFACTURER OF SUCH PRODUCTS. THE SUBCONTRACTOR SHALL PREPARE A WRITTEN RECORD OF ANY SPILL AND ASSOCIATED CLEAN-UP ACTIVITIES OF PETROLEUM PRODUCTS OR HAZARDOUS MATERIALS IN EXCESS OF 1 GALLON OR REPORTABLE QUANTITIES, WHICHEVER IS LESS, ON THE DAY OF THE SPILL. THE SUBCONTRACTOR SHALL PROVIDE NOTICE TO OWNER, VIA THE ONLINE CRITICAL INCIDENT REPORT, IMMEDIATELY UPON IDENTIFICATION OF ANY SPILL. SPILL REPORT FORMS ARE AVAILABLE IN THE ONLINE SWPPP REPORTING SYSTEM PROVIDED BY THE OWNER. COPIES OF SPILL CRITICAL INCIDENT REPORTS SHALL BE PRINTED AND MAINTAINED IN THE JOBSITE BINDER. ANY SPILLS OF PETROLEUM PRODUCTS OR HAZARDOUS MATERIALS IN EXCESS OF REPORTABLE QUANTITIES AS DEFINED BY EPA OR THE STATE OR LOCAL AGENCY REGULATIONS, SHALL BE IMMEDIATELY REPORTED TO THE EPA NATIONAL RESPONSE CENTER (1-800-424-8802) AND THE MINNESOTA DEPARTMENT OF NATURAL RESOURCES (1-800-943-0003) THE STATE REQUIRES REPORTING WHEN: ·THERE IS AN IMPACT TO HUMAN HEALTH ·THERE IS AN IMPACT TO THE ENVIRONMENT ·THERE IS A FIRE, EXPLOSION, OR SAFETY HAZARD ·A SPILL IS NOT IMMEDIATELY CLEANED UP ·THE SPILL WAS MORE THAN THE REPORTABLE QUANTITY OF 1 GALLON OF A PETROLEUM PRODUCT THE REPORT SHOULD BE FILED WITH THE STATE OF MINNESOTA. ALL REPORTS SHOULD BE FILED WITHIN 24 HOURS OF A SPILL OCCURRING. THE REPORTABLE QUANTITY FOR HAZARDOUS MATERIALS CAN BE FOUND IN 40 CFR 302 AND THE US EPA WEBSITE: HTTP://WWW.EPA.GOV/SUPERFUND/POLICY/RELEASE/RG TO MINIMIZE THE POTENTIAL FOR A SPILL OF PETROLEUM PRODUCT OR HAZARDOUS MATERIALS TO COME IN CONTACT WITH STORMWATER, THE FOLLOWING STEPS SHALL BE IMPLEMENTED: 1)ALL MATERIALS WITH HAZARDOUS PROPERTIES, SUCH AS PESTICIDES, PETROLEUM PRODUCTS, FERTILIZERS, SOAPS, DETERGENTS, CONSTRUCTION CHEMICALS, ACIDS, BASES, PAINTS, PAINT SOLVENTS, ADDITIVES FOR SOIL STABILIZATION, CONCRETE, CURING COMPOUNDS AND ADDITIVES, ETC., SHALL BE STORED IN A SECURE LOCATION, UNDER COVER AND IN APPROPRIATE, TIGHTLY SEALED CONTAINERS WHEN NOT IN USE. 2)THE MINIMUM PRACTICAL QUANTITY OF ALL SUCH MATERIALS SHALL BE KEPT ON THE JOB SITE AND SCHEDULED FOR DELIVERY AS CLOSE TO TIME OF USE AS PRACTICAL. 3)A SPILL CONTROL AND CONTAINMENT KIT (CONTAINING FOR EXAMPLE, ABSORBENT MATERIAL SUCH AS KITTY LITTER OR SAWDUST, ACID, BASE, NEUTRALIZING AGENT, BROOMS, DUST PANS, MOPS, RAGS, GLOVES, GOGGLES, PLASTIC AND METAL TRASH CONTAINERS, ETC.) SHALL BE PROVIDED AT THE CONSTRUCTION SITE AND ITS LOCATION(S) SHALL BE IDENTIFIED WITH LEGIBLE SIGNAGE AND SHOWN ON SITE MAPS. a.THE SPILL CONTROL AND CONTAINMENT KIT SUPPLIES SHALL BE OF SUFFICIENT QUANTITIES AND APPROPRIATE CONTENT TO CONTAIN A SPILL FROM THE LARGEST ANTICIPATED PIECE OF EQUIPMENT AND FROM THE LARGEST ANTICIPATED QUANTITIES OF PRODUCTS STORED ON THE SITE AT ANY GIVEN TIME. b.CONTENTS SHALL BE INSPECTED DAILY DURING THE DAILY STORMWATER INSPECTION. 4)ALL PRODUCTS SHALL BE STORED IN AND USED FROM THE ORIGINAL CONTAINER WITH THE ORIGINAL PRODUCT LABEL. CONTAINERS MUST BE STORED IN A MANNER TO PROTECT THEM FROM THE ELEMENTS AND INCIDENTAL DAMAGE. 5)ALL PRODUCTS SHALL BE USED IN STRICT COMPLIANCE WITH INSTRUCTIONS ON THE PRODUCT LABEL. 6)THE DISPOSAL OF EXCESS OR USED PRODUCTS SHALL BE IN STRICT COMPLIANCE WITH INSTRUCTIONS ON THE PRODUCT LABEL AND REGULATIONS. HAZARDOUS MATERIAL MANAGEMENT & SPILL REPORTING UPON IMPLEMENTATION AND INSTALLATION OF THE FOLLOWING AREAS: TRAILER, PARKING, LAYDOWN, PORTA-POTTY, WHEEL WASH, CONCRETE WASHOUT, FUEL AND MATERIAL STORAGE CONTAINERS, SOLID WASTE CONTAINERS, ETC., IMMEDIATELY DENOTE THEM ON THE SITE MAPS AND NOTE ANY CHANGES IN LOCATION AS THEY OCCUR THROUGHOUT THE CONSTRUCTION PROCESS. BMP AND EROSION CONTROL INSTALLATION SEQUENCE SHALL BE AS FOLLOWS: 1.TEMPORARILY SEED, THROUGHOUT CONSTRUCTION, DENUDED AREAS THAT WILL BE INACTIVE FOR 7 DAYS OR MORE. 2.INSTALL UTILITIES, UNDERDRAINS, STORM SEWERS, UNDERGROUND SYSTEM, CURBS AND GUTTERS. 3.INSTALL APPROPRIATE INLET PROTECTION AT ALL STORM SEWER STRUCTURES AS EACH INLET STRUCTURE IS INSTALLED. 4.PERMANENTLY STABILIZE AREAS TO BE VEGETATED AS THEY ARE BROUGHT TO FINAL GRADE. 5.PREPARE SITE FOR PAVING. 6.PAVE SITE AND INSTALL STRIPING. 7.INSTALL APPROPRIATE INLET PROTECTION DEVICES FOR PAVED AREAS AS WORK PROGRESSES. 8.COMPLETE GRADING AND INSTALLATION OF PERMANENT STABILIZATION OVER ALL AREAS. 9.OBTAIN CONCURRENCE WITH THE CIVIL ENGINEERING CONSULTANT THAT THE SITE HAS BEEN FULLY STABILIZED THEN: 1.REMOVE ALL REMAINING TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES 2.STABILIZE ANY AREAS DISTURBED BY THE REMOVAL OF BMPS. THE GC MUST UPDATE THE SWPPP, INCLUDING THE JOBSITE BINDER AND SITE MAPS, TO REFLECT THE PROGRESS OF CONSTRUCTION ACTIVITIES AND GENERAL CHANGES TO THE PROJECT SITE. UPDATES SHALL BE MADE DAILY TO TRACK PROGRESS WHEN ANY OF THE FOLLOWING ACTIVITIES OCCUR: BMP INSTALLATION, MODIFICATION OR REMOVAL, CONSTRUCTION ACTIVITIES (E.G., PAVING, STORM SEWER INSTALLATION, FOOTING INSTALLATION, ETC.), CLEARING, GRUBBING OR GRADING, OR TEMPORARY OR PERMANENT STABILIZATION. IMPORTANT: THE GENERAL CONTRACTOR MUST SUBMIT A REQUEST FOR INFORMATION (RFI) TO THE CEC AND OBTAIN WRITTEN CEC APPROVAL BEFORE DOING ANY OF THE FOLLOWING: 1.MODIFYING EROSION OR SEDIMENT CONTROL BMPS (SUBSTITUTIONS ARE TYPICALLY ONLY APPROVED IF SPECIFIED MATERIALS ARE NOT AVAILABLE OR THERE IS A VALID REASON THE SPECIFIED BMP WILL NOT WORK) 2.ADDING/DELETING EROSION OR SEDIMENT CONTROL BMPS; 3.MODIFYING THE SWPPP IMPLEMENTATION SEQUENCE; OR 4.PERFORMING ANY ACTIONS OR IN ANY MANNER THAT IS CONTRARY TO THE SWPPP. THE CONTRACTOR MAY MODIFY OR ADD ADDITIONAL BMPS, WITHOUT CEC APPROVAL, IN AN EMERGENCY SITUATION TO PREVENT SEDIMENT DISCHARGE OR PROTECT WATER QUALITY; HOWEVER, GC MUST NOTIFY THE CEC AS SOON AS PRACTICAL AS TO THEIR ACTIONS TO DISCUSS THE NEED FOR ADDITIONAL OR SUPPLEMENTAL MEASURES AND TO OBTAIN THE REQUIRED APPROVALS. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE TO ENSURE COMPLIANCE WITH THE PERMIT AND PROTECTION OF DOWNSTREAM WATER QUALITY. AMENDING THE SWPPP DOES NOT MEAN THAT IT HAS TO BE REPRINTED. IT IS ACCEPTABLE TO ADD ADDENDA, SKETCHES, NEW SECTIONS, DETAILS, AND/OR REVISED DRAWINGS THAT HAVE THE CEC NAME IN PRINT, ARE STAMPED, SIGNED, DATED, AND ARE ACCOMPANIED BY WRITTEN COPY OF THE ASSOCIATED RFI AND ITS RESPONSE FROM CEC. ENGINEERED ITEMS MUST BE SIGNED AND STAMPED BY THE CEC OF RECORD FOR THE PROJECT. 1.ALL MEASURES STATED ON THE EROSION AND SEDIMENT CONTROL PLAN AND IN THE STORM WATER POLLUTION PREVENTION PLAN, SHALL BE MAINTAINED IN FULLY FUNCTIONAL CONDITION UNTIL FINAL STABILIZATION OF THE SITE. ALL EROSION SEDIMENTATION CONTROL MEASURES SHALL BE CHECKED BY A QUALIFIED PERSON AT LEAST ONCE EVERY SEVEN CALENDAR DAYS, AND WITHIN 24 HOURS AT THE END OF A RAINFALL EVENT AND SHOULD BE CLEANED AND REPAIRED IN ACCORDANCE WITH THE FOLLOWING 1.1.INLET PROTECTION AND BARRIERS SHALL BE REPAIRED OR REPLACED IF THEY SHOW SIGNS OF UNDERMINING OR SHALL BE REPLACED IF THEY SHOW SIGNS OF DETERIORATION 1.2.ALL SEEDED AREAS SHALL BE CHECKED REGULARLY TO SEE THAT A GOOD STAND IS MAINTAINED. AREAS SHOULD BE FERTILIZED AND RESEEDED AS NEEDED 1.3.SILT FENCES AND BRIO-ROLL SHALL BE REPAIRED TO THEIR ORIGINAL CONDITION IF DAMAGED. SEDIMENT SHALL BE REMOVED FROM THE SILT FENCES WHEN IT REACHES ONE-THIRD TO ONE-HALF HEIGHT OF THE FENCE. 1.4.THE CONSTRUCTION ENTRANCES SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHTS OF WAY. 1.5.THE TEMPORARY PARKING AND STORAGE AREA SHALL BE KEPT IN GOOD CONDITION (SUITABLE FOR PARKING AND STORAGE). THIS MAY REQUIRE PERIODIC TOP DRESSING OF THE TEMPORARY PARKING AREA AS CONDITIONS DEMAND. SEQUENCE OF CONSTRUCTION SWPPP UPDATES AND AMENDMENTS MAINTENANCE SWPPP DESIGNER: INSTALLER CERTIFICATION NAME: ADDRESS: SWPPP CERTIFICATION: SIGNATURE: INSPECTOR CERTIFICATION NAME: ADDRESS: SWPPP CERTIFICATION: SIGNATURE: IMPAIRED WATERS SITE 1 MILE UN I V E R S I T Y A V E N E US 6 9 4 ST I N S O N B L V D N E 40TH AVE NE CE N T R A L A V E N E HIGHLAND LAKE SULLIVAN LAKE PR E P A R E D F O R SW P P P C303 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 NAME: ADDRESS: SWPPP CERTIFICATION: SIGNATURE: PHASE I & II BMP QUANTITIES SILT FENCE ±518 LF INLET PROTECTION 9 EA ROCK CONSTRUCTION ENTRANCE 1 EA BIO ROLL 186 LF EROSION CONTROL BLANKET ±12,443 SF AREA SUMMARY TOTAL PROPERTY AREA 1.23 AC / 53,589 SF EXISTING IMPERVIOUS AREA 0.00 AC / 0.0% EXISTING PERVIOUS AREA 1.23 AC / 53,589 SF / 100% PROPOSED IMPERVIOUS AREA 0.78 AC / 33,846 SF / 63% PROPOSED PERVIOUS AREA 0.45 AC / 19,503 SF / 37% TOTAL DISTURBED AREA 1.18 AC / 51,762 SF 67 Item 5. G R A N D A V E N U E N E C E N T R A L A V E N U E N E 4 7 T H A V E N U E N E G R A N D A V E N U E N E C E N T R A L A V E N U E N E 4 7 T H A V E N U E N E CAR WASH BUILDING 6,200 S.F. 947.00 FFE 48.0' AD A AD A AD A AD A AD A ADA ADA ADA ADA ADA ADA ADA ADA R8 R4 P4P4 P4 P4 R1 R6 R1 R1 R1 R1 R3 R2 P3 S2 S3 S5 C1 F1 F1 F2 P3 S4 S1 C9 C9 P2 P1 S6 S5 C1 C1 R10.0' R15.0' R10.0' R3.0' R3.0' R10.0' R10.0' R10.0' R2.0' R2.0' R15.0' R2.0'R3.0' 15 . 0 ' B U I L D I N G A N D P A R K I N G SE T B A C K 15.0' BUILDING AND PARKING SETBACK 10.5' 50.6' 15 . 0 ' 3. 7 ' 24 . 0 ' 20 . 6 ' 30 . 0 ' 5. 0 ' 27 . 2 ' 12 . 0 ' 12 . 0 ' 12 . 0 ' 12 . 0 ' 10 . 0 ' 31.7' C5 29.0' C8 C8 C8 2' LANDSCAPING WALL, SEE GRADING PLAN FOR ELEVATION (4) EMPLOYEE PARKING STALLS 30' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 10' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 40' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 10' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 30' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION EXISTING PROPERTY LINE PROPOSED PROPERTY LINE C2 C2 P5 R9 R9 R9 R9 R9 R9 R9R9 R9 R9 R9 R9 TYP. C9 C9 C3 C3 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C10 C4 C9 C10 C3 C3 R3.0' R3.0'R3.0'R2.0' C10 C10 C7 C7 C7 C7 C7 20.0' BUILDING SETBACK T R7 R20.0' 51.6' 77 . 8 ' 17.0' 90 . 3 ' 30 . 0 ' 40 . 0 ' R2 16.0' 20 . 0 ' 9.0' 20 . 0 ' 8' TALL BRICK WALL 2. 0 ' 5. 2 ' 5 4 . 3 ' R2.0'R2.0' R28.0' R5.0' 77 . 2 ' R10 R2.0' R2.0' RETAINING WALL WITH FENCE INSTALLED ON TOP OF WALL, SEE GRADING PLAN FOR ELEVATIONS AND HEIGHT INSTALLED ON TOP OF WALL COORDINATE INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT WITH STRUCTURAL RETAINING WALL DESIGN INSTALLED ON TOP OF WALL Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 4 - S I T E P L A N . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 5 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M © IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N LEGENDPROPERTY SUMMARY TOTAL PROPOSED PROPERTY AREA (INCLUDING LOT LINE ADJUSTMENT)1.23 AC / 53,589 SF DISTURBED AREA 1.18 AC / 51,762 SF EXISTING IMPERVIOUS AREA 0.00 AC / 0.0% EXISTING PERVIOUS AREA 1.23 AC / 53,589 SF / 100% PROPOSED IMPERVIOUS AREA 0.78 AC / 33,846 SF / 65% PROPOSED PERVIOUS AREA 0.45 AC / 19,503 SF / 35% NET INCREASE IN IMPERVIOUS AREA 0.78 AC / 33,846 SF SITE PLAN NOTES 1.REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF STOOPS, TRUCK DOCKS, TRASH ENCLOSURES & PRECISE BUILDING DIMENSIONS. REFER TO THE SITE ELECTRICAL PLAN FOR LOCATIONS OF PROPOSED LIGHT POLES, CONDUITS, AND ELECTRICAL EQUIPMENT. 2.REFER TO CERTIFIED SITE SURVEY OR PLAT FOR EXACT LOCATION OF EXISTING EASEMENTS, PROPERTY BOUNDARY DIMENSIONS, AND ADJACENT RIGHT-OF-WAY & PARCEL INFORMATION. 3.DIMENSIONS AND RADII ARE DRAWN TO THE FACE OF CURB, UNLESS OTHERWISE NOTED. DIMENSIONS ARE ROUNDED TO THE NEAREST TENTH FOOT, AND AREAS ARE ROUNDED TO THE NEAREST SQUARE FOOT. 4.UNLESS OTHERWISE NOTED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING EXISTING SITE IMPROVEMENTS THAT CONFLICT WITH THE PROPOSED WORK, INCLUDING BUT NOT LIMITED TO TRAFFIC SIGNS, LIGHT POLES, ABOVEGROUND UTILITIES, ETC. PERFORM WORK IN ACCORDANCE WITH GOVERNING AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS. COST SHALL BE INCLUDED IN BASE BID. 5.TYPICAL PARKING STALL DIMENSIONS SHALL BE 9.0-FEET IN WIDTH AND 20-FEET IN LENGTH UNLESS OTHERWISE INDICATED. 6.MONUMENT SIGN(S) ARE DETAILED ON THE ARCHITECTURAL PLANS AND ARE SHOWN FOR GRAPHICAL & INFORMATIONAL PURPOSES ONLY. CONTRACTOR TO VERIFY SIGN DIMENSIONS, LOCATION AND REQUIRED PERMITS WITH THE OWNER. PR E P A R E D F O R SI T E D I M E N S I O N PL A N C400 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 PARKING SUMMARY REQUIRED PARKING 2 SPACES PER BAY, PLUS 4 STACKING SPACES PER BAY TOTAL PROPOSED PARKING 12 SPACES (5 PARKING, 7 VACUUM STALLS) REQUIRED ACCESSIBLE PARKING 1 STANDARD SPACES 1 VAN ACCESSIBLE PROPOSED ACCESSIBLE PARKING 1 STANDARD SPACES 1 VAN ACCESSIBLE PROPOSED CURB AND GUTTER PROPERTY LINE SETBACK LINE LANDSCAPING WALL DRAINAGE AND UTILITY EASEMENT HEAVY DUTY CONCRETE PAVEMENT SEE DETAILS FOR SECTION STANDARD DUTY CONCRETE PAVEMENT SEE DETAILS FOR SECTION CONCRETE SIDEWALK SEE DETAILS FOR SECTION SITE DATA EXISTING ZONING MXD - MIXED-USE DISTRICT FUTURE - COMMERCIAL/BUSINESS PROPOSED ZONING MXD - MIXED-USE DISTRICT FUTURE - COMMERCIAL/BUSINESS PROPOSED LAND USE CAR WASH PARKING SETBACKS FRONT = 15' SIDE = 15' REAR = 5' BUILDING SETBACKS FRONT = 15' SIDE = 15' REAR = 20' BUILDING DATA TOTAL BUILDING AREA 6,200 SF PERCENT OF TOTAL PROPERTY AREA 6.8% MAXIMUM BUILDING HEIGHT 35 FT KEYNOTE LEGEND CURB, SIDEWALK & PAVEMENT MATCH EXISTING EDGE OF PAVEMENT/CURB & GUTTER COMMERCIAL DRIVEWAY APRON - SEE DETAIL 6" CONCRETE CURB & GUTTER - TIP-IN (TYP). - SEE DETAIL 6" CONCRETE CURB & GUTTER - TIP-OUT (TYP). - SEE DETAIL ACCESSIBLE CURB RAMP - SEE DETAIL BOLLARD (SEE DETAIL) FLUSH CURB (SEE DETAIL) CONCRETE SIDEWALK (SEE DETAIL) CONCRETE ROLL CURB (SEE DETAIL) TRANSITION CURB SITE FIXTURES BUG GATE (SEE LAYOUT DETAIL) VACUUM ASSEMBLY (BY OWNER) PAVEMENT MARKINGS ACCESSIBLE PARKING SYMBOL & LOADING AREA - SEE DETAIL STRIPED WHITE CROSS-HATCH AREA 4" SOLID LINES @ 45° 2' O.C. 4" WIDE WHITE PAINTED SOLID PARKING LOT LINE PAINTED WHITE DIRECTIONAL ARROW - SEE DETAIL 24" WIDE STOP BAR SIGNAGE MENU BOARD SIGN - BY OWNER STOP SIGN - SEE DETAIL ADA PARKING SIGN (TYP) - SEE DETAIL ENTER SIGN - BY OWNER PYLON SIGN - BY OWNER NO PARKING SIGN - SEE DETAIL REFERENCE NOTES AT-GRADE BUILDING ENTRY & STRUCTURAL STOOP (REFER TO ARCH & STRUCTURAL PLANS) OVERHEAD VEHICLE DOOR (REFER TO ARCH PLANS) INTERIOR TRASH ENCLOSURE (REFER TO ARCH PLANS) CONCRETE ISLAND & GATE ARMS (BY OWNER) OVERHEAD CANOPY (REFER TO ARCH PLANS) INTERIOR STORAGE (REFER TO ARCH PLANS) TRANSFORMER - REFER TO ELECTRICAL SITE PLAN OVERHEAD CANOPY - REFER TO ARCH PLANS LIGHT POLES - REFER TO ELECTRICAL SITE PLAN C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 F1 F2 P1 P2 P3 P4 P5 S1 S2 S3 S4 S5 S6 R1 R2 R3 R4 R5 R6 R7 R8 R9 Know what'sbelow. before you dig.Call R NO R T H 0 GRAPHIC SCALE IN FEET 20 10 20 40 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E 68 Item 5. G R A N D A V E N U E N E C E N T R A L A V E N U E N E 4 7 T H A V E N U E N E G R A N D A V E N U E N E C E N T R A L A V E N U E N E 4 7 T H A V E N U E N E CAR WASH BUILDING 6,200 S.F. 947.00 FFE Co l u m b i a H e i g h t s I m p e l A s c e n d a n t Cu s t o m (c) 2 0 2 6 T r a n s o f t S o l u t i o n s , I n c . A l l r i g h t s r e s e r v e d . Co l u m b i a H e i g h t s I m p e l A s c e n d a n t Cu s t o m (c ) 2 0 2 6 T r a n s o f t S o l u t i o n s , I n c . A l l r i g h t s r e s e r v e d . Columbia Heights Impel Ascendant Custom Co l u m b i a H e i g h t s I m p e l A s c e n d a n t Cu s t o m 10.5' 24 . 0 ' 58 . 0 ' 31.7' EXISTING PROPERTY LINE PROPOSED PROPERTY LINE T 17.0' 30 . 0 ' 40 . 0 ' 155.3' 40 . 5 ' 150.0' 29.0' PROPOSED 10' CLR ROOF CANOPY Columbia Heights Pierce Impel Pumper Custom (c) 2026 Transoft Solutions, Inc. All rights reserved. Co l u m b i a H e i g h t s P i e r c e I m p e l P u m p e r Cu s t o m (c) 2 0 2 6 T r a n s o f t S o l u t i o n s , I n c . A l l r i g h t s r e s e r v e d . Co l u m b i a H e i g h t s P i e r c e I m p e l P u m p e r Cu s t o m Co l u m b i a H e i g h t s P i e r c e I m p e l P u m p e r Cu s t o m (c) 2 0 2 6 T r a n s o f t S o l u t i o n s , I n c . A l l r i g h t s r e s e r v e d . Columbia Heights Pierce Impel Pumper Custom (c) 2026 Transoft Solutions, Inc. All rights reserved. R10.0' R10.0' R10.0' Lock to Lock Time Track Width : : : feet Columbia Heights Impel Ascendant 6.0 6.91 8.33 19.4611.46 42.88 Steering Angle 40.0: Lock to Lock Time Track Width : : : inches Columbia Heights Impel Ascendant 6.0 82.9 100.0 233.5137.5 514.5 Steering Angle 40.0: :40.0Steering Angle 8.08 16.50 8.33 6.91 6.0 Columbia Heights Pierce Impel Pumper feet : : : Width Track Lock to Lock Time 32.42 :40.0Steering Angle 97.0 198.0 100.0 82.9 6.0 Columbia Heights Pierce Impel Pumper inches : : : Width Track Lock to Lock Time 389.0 Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 4 - F I R E C I R C U L A T I O N P L A N . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 5 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M © IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N LEGEND PR E P A R E D F O R FI R E C I R C U L A T I O N PL A N C401 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 PARKING SUMMARY REQUIRED PARKING 2 SPACES PER BAY, PLUS 4 STACKING SPACES PER BAY TOTAL PROPOSED PARKING 12 SPACES (5 PARKING, 7 VACUUM STALLS) REQUIRED ACCESSIBLE PARKING 1 STANDARD SPACES 1 VAN ACCESSIBLE PROPOSED ACCESSIBLE PARKING 1 STANDARD SPACES 1 VAN ACCESSIBLE PROPOSED CURB AND GUTTER PROPERTY LINE SETBACK LINE LANDSCAPING WALL DRAINAGE AND UTILITY EASEMENT HEAVY DUTY CONCRETE PAVEMENT SEE DETAILS FOR SECTION STANDARD DUTY CONCRETE PAVEMENT SEE DETAILS FOR SECTION CONCRETE SIDEWALK SEE DETAILS FOR SECTION SITE DATA EXISTING ZONING MXD - MIXED-USE DISTRICT FUTURE - COMMERCIAL/BUSINESS PROPOSED ZONING MXD - MIXED-USE DISTRICT FUTURE - COMMERCIAL/BUSINESS PROPOSED LAND USE CAR WASH PARKING SETBACKS FRONT = 15' SIDE = 15' REAR = 5' BUILDING SETBACKS FRONT = 15' SIDE = 15' REAR = 20' BUILDING DATA TOTAL BUILDING AREA 6,200 SF PERCENT OF TOTAL PROPERTY AREA 6.8% MAXIMUM BUILDING HEIGHT 35 FT Know what'sbelow. before you dig.Call R NO R T H 0 GRAPHIC SCALE IN FEET 20 10 20 40 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S KB P DL E 69 Item 5. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 4 - S I T E D E T A I L S . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 6 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 20" 5'-0" 6" MATCH GEOMETRY OF CURB & GUTTER 6" 1" A T L A Y D O W N C U R B 0" A T R I B B O N C U R B NOTES: 1.REFER TO CONCRETE CURB & GUTTER DETAIL FOR SPECIFICATIONS AND AGGREGATE BASE COURSE DIMENSIONS NO SCALE CONCRETE CURB TAPER7 STEEL SIGN POST RESERVED PARKING VAN ACCESSIBLE NOTES: 1.SIGNS SHALL BE 18 GAUGE STEEL, WITH BAKED ENAMEL WHITE LETTERS AND BORDER ON BLUE BACKGROUND, WHERE APPLICABLE. 2.POST SHALL BE GALVANIZED STEEL U-CHANNEL, PERFORATED WITH 3/8" HOLES AT 1" CENTERS 3.SIGNS SHALL COMPLY WITH LOCAL MUTCD REQUIREMENTS FINISHED GRADE 5' - 0 " 3' - 6 " 12"x8" VAN-ACCESSIBLE SIGN 12"x8" HANDICAP PARKING SIGN NO SCALE ACCESSIBLE PARKING SIGN8 41 " 4" (TYPICAL) CL 36" R 2 . 5 ' NO SCALE ACCESSIBLE PARKING SYMBOL2 2' 45° NO SCALE TYPICAL CROSS HATCHING MARKINGS3 4" SOLID LINE WHITE (TYP.) NOTE: ALL TRAFFIC FLOW ARROWS TO BE SOLID WHITE REFLECTIVE TRAFFIC PAINT AS PER DIMENSIONS ABOVE 2' 1. 7 5 ' 3. 7 5 ' 1'4.75' R 2 . 0 ' NO SCALE TRAFFIC ARROW1 13 " 6" 6" 7" 8"12" 3 1 3/ 8 " 1/2" PER FOOT NO SCALE 6" CURB & GUTTER (TIP-OUT)5 1/2" R 1/2" R 3" R3" R TOP BIT. MAT BASE 30"x30" R1-1 STEEL SIGN POST NOTES: 1.SIGNS SHALL BE 18 GAUGE STEEL 2.POSTS SHALL BE GALVANIZED STEEL U-CHANNEL, PERFORATED WITH 3/8" HOLES AT 1" CENTERS 3.SIGNS SHALL COMPLY WITH LOCAL MUTCD REQUIREMENTS FINISHED GRADE 7' - 0 " 3' - 6 " BREAK-AWAY 3/8"Ø PAN HEAD MACHINE SCREW w/HEX NUT & WASHERS 6" M A X SCALE: NTS TRAFFIC SIGN POST10 NO PARKING NO SCALE VACUUM STATION THICKENED SLAB 11 NO SCALE ROLL CURB9 NO SCALE BUG GATE LAYOUT4 NO SCALE 6" CURB & GUTTER (TIP-IN)6 12" 6" 8" 6" 1/2" R 3 1 7 1/2" 13 1/2" 3" R 1/2" R 3/4" PER FOOT 3/8" 7" BASE TOP BIT. MAT. 1/2" R PR E P A R E D F O R SI T E D E T A I L S C402 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E 70 Item 5. DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 4 - S I T E D E T A I L S . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 6 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N 6" PORTLAND CEMENT CONCRETE (NON REINFORCED) 6" AGGREGATE BASE PROPERLY PREPARED FILLS, NATURAL SUB-GRADE SOILS, AND/OR STRUCTURAL SITE GRADING FILL NO SCALE STANDARD DUTY CONCRETE PAVMENT SECTION14 8" PORTLAND CEMENT CONCRETE (NON REINFORCED) 6" AGGREGATE BASE PROPERLY PREPARED FILLS, NATURAL SUB-GRADE SOILS, AND/OR STRUCTURAL SITE GRADING FILL NO SCALE HEAVY DUTY CONCRETE PAVMENT SECTION15 PAVEMENT SECTIONS SHOWN ARE PROVIDED AS A REFERENCE ONLY. REFER TO GEOTECHNICAL REPORT FOR ALL PAVEMENT, SUBGRADE PREPARATION AND COMPACTION REQUIREMENTS. NO SCALE BIKE RIBBON RACK12 4" STEEL TROWLED EDGES AND JOINTS COARSE BROOM FINISH 1/2" EXPANSION JOINT VERY 60', CONTRACTION JOINT EVERY 6' MEMBRANE CURING COMPOUND (200 SF/GALLON) (STD. WALK AND MEDIAN ONLY) 5" CONCRETE WALK 4" COMPACTED, APPROVED SUBGRADE NOTES: 1.ALL EXCAVATION, COMPACTION AND BACKFILL INCIDENTAL TO UNIT PRICE BID FOR 4" SIDEWALK NO SCALE CONCRETE SIDEWALK13 PR E P A R E D F O R SI T E D E T A I L S C402 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S DW C DL E 71 Item 5. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 4 - S I T E D E T A I L S . d w g J u l y 0 6 , 2 0 2 6 - 2 : 0 9 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . FI R S T M . L A S T 05 / 2 7 / 2 0 2 6 12 3 4 5 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N XX X XX X XX X PR E P A R E D F O R SI T E D E T A I L S C404 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN NO SCALE LANDSCAPE WALL1 NOTES: 1.LANDSCAPING WALL IS PRELIMINARY AND SUBJECT TO CHANGE. OWNER OR CONTRACTOR RESPONSIBLE FOR PROCURING LANDSCAPE WALL FROM MANUFACTURER. FINAL DESIGN BY OTHERS. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO CONSTRUCTION. 1'-0"12"9'-0" 1' - 0 " 1' - 8 " VA R I E S VA R I E S 3" CL R 2" CL R FILL AS REQUIRED BY GEOTECH 2"CLR2"CLR #8 @ 12" OC EF T.O. FOOTING ELEVATION 2' - 8 " 3"CLR, TYP 5' - 0 " L A P #8 @ 12" OC, T&B #6 @ 12" OC, EF T.O. WALL ELEVATION #6 @ 12" OC, T&B T.O. GRADING, SEE CIVIL ORNAMENTAL FENCE, SUCH AS AMERISTAR ECHELON II MAJESTIC, OR OWNER AND AHJ APPROVED EQUIVALENT, TO BE INSTALLED AT TOP OF WALL. COORDINATE OPENINGS IN FENCE WITH EQUIPMENT INSTALLED ON TOP OF THE WALL, SEE CIVIL PLANS 15 " M I N T.O. GRADING, SEE CIVIL UNDER DRAIN. AT DAYLIGHT LOCATIONS OF UNDER DRAIN: AVOID INTERFERENCE WITH WALL REINFORCEMENT AND PROVIDE CLEAR COVER BETWEEN DRAIN AND REINFORCEMENT. #4 @12" OC U-BARS AT TOP OF WALL. PROVIDE 18" LEGS. SE E C I V I L G R A D I N G P L A N NO SCALE RETAINING WALL3 NOTES: 1.RETAINING WALL DESIGN IS PRELIMINARY. FINAL DESIGN WILL BE COMPLETED BY STRUCTURAL ENGINEER. CONTRACTOR TO SUBMIT REQUIRED SHOP DRAWINGS FOR APPROVAL PRIOR TO CONSTRUCTION. NO SCALE ORNAMENTAL FENCE2 8 3 4 2 1 5 67 SS D D SS S S S S S G R A N D A V E N U E N E C E N T R A L A V E N U E N E 4 7 T H A V E N U E N E SS S S S S S ST ST S ST ST ST ST ST 10" DIP 10" W.M. 6" C.I.P. ST ST CAR WASH BUILDING 6,200 S.F. 947.00 FFE D CO CO SCOCO S CO 9 4 1 94 2 94 3 944 945 946 947 948 949 95 0 951 952 953 9 5 4 95 4 955 9 5 6 932 93 3 934 9 3 4 9 3 4 935 9 3 5 9 3 5 936 9 3 6 936 9 3 7 937 937 9 3 8 938 938 93 9 94 0 94 1 94 2 94 3 94 4 94 5 94 6 947 948 949 950 951 952 953 954 9 3 6 93 7 9 3 8 93 9 940 941 942 943 943 944 944 940 941 9 4 2 9 4 3 944 945 946 9 4 1 9 4 2 9 4 3 94 4 945 946 947 948 949 950 951 952 953 954 UNDERGROUND DETENTION SYSTEM ADS MC-7200 CHAMBERS OR APPROVED ALTERNATIVE ±10,505 CF STORAGE BOTTOM OF STONE: 936.50 BOTTOM OF CHAMBER: 937.25 TOP OF CHAMBER: 942.25 942 943 944 945 9 4 6 946 946 9 4 6 946 947 947 9 4 7 9 4 8 9 4 9 9 5 0 947 948 949 950 94 7 9 4 8 948 94 7 7.0 3 % 8.70 % 4. 9 2 % 4.80% 9. 8 3 % 1.2 8 % 4. 3 2 % 3 . 3 8 % 3 . 8 5 % 3 . 2 0 % 2 . 6 3 % 2.96% 3 . 8 4 % 4.81% 1 . 2 4 % 3. 4 1 % 3 . 0 9 % 3.99% 1 . 3 1 % 2.7 3 % 3:1 3: 1 4: 1 4: 1 4 : 1 0.69% 1 . 6 3 % 4: 1 CBMH 104 RE: 945.58 STMH 102 RE: 945.33 CBMH 101 RE: 944.99 CBMH 103 RE: 944.98 STMH 100 RE: 943.55 STUB 01 STUB 6 CONNECT TO EXISTING STORM SEWER STMH 02 STUB RD-A STUB RD-B STUB RD-C NYLOPLAST 105 RE: 945.85 NYLOPLAST 106 RE: 946.30 CBMH 107 RE: 945.00 G:947.66 G:947.77 G:948.78 G:947.96 G:946.69 G:947.09 G:948.17 G:946.64 G:946.87 G:946.97 G:947.88 G:947.23 G:946.99 G:946.87 G:947.02 G:946.92 G:946.04G:945.72 G:946.76 G:946.93 G:945.29 945.14 G:945.29 LP:944.99 945.51 G:946.25 946.61 G:947.30 946.80 G:946.00 G:947.63 G:945.89 946.64 G:944.88 ME:943.97 ME:946.13 ME:948.11 ME:953.44 G:945.79 G:946.93 FFE = 947.0 FFE = 947.0 FFE = 947.0FFE = 947.0 946.80 FFE = 947.0 946.33 FFE = 947.0 946.33946.80 TW:951.81 TW:952.49TW:953.06TW:951.44 BW:951.18 BW:951.07 BW:950.49 BW:951.50 946.49 ME:953.44 953.37 953.37 952.59952.73 950.49 G:950.56 G:946.95 G:946.95 G:945.13 LP:944.97 T/G:945.40 T/G:945.29 944.85 944.90 944.78 944.75 944.83 ME:943.81 G:944.81 944.73 ME:944.23 G:946.48 G:946.57 G:946.96 G:946.90 G:946.89 G:946.96 G:947.80 G:946.97 G:946.93 G:946.97 G:946.97 G:946.93 G:946.93 G:946.97 G:946.95 G:946.98 G:946.98 G:946.95 G:948.67 947.88 ME:950.73 HP:945.52 LP:945.00 G:945.27 G:945.24 G:945.61 G:945.54 G:945.60 PROPOSED PROPERTY LINE 3:1 4: 1 TW:946.50 BW:945.00 TW:946.70 BW:943.47 TW:947.50 BW:942.25 TW:948.15 BW:941.56 TW:947.91 BW:946.91 TW:948.46 BW:946.07 TW:949.28 BW:940.60 TW:948.09 BW:939.09 953 954 955 945 94 6 942 943 944 945 941 940 94 094 1 9 4 2 9 4 3 9 4 4 945 ME:938.76 ME:940.58 ME:945.92 ME:946.75 ME:938.83 ME:955.02 CO 100A RE: 942.75 NYLOPLAST 100B RE: 941.38 Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 5 - G R A D I N G P L A N . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 6 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M © IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N GRADING PLAN NOTES 1.PERFORM GRADING WORK IN ACCORDANCE WITH APPLICABLE CITY SPECIFICATIONS AND BUILDING PERMIT REQUIREMENTS. 2.CONTACT STATE 811 CALL-BEFORE-YOU-DIG LOCATING SERVICE AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATION FOR UNDERGROUND UTILITY LOCATIONS. 3.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL. 4.FIELD VERIFY THE LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIOR TO THE START OF LAND DISTURBING ACTIVITIES. NOTIFY THE PROJECT ENGINEER OF ANY DISCREPANCIES OR VARIATIONS IMPACTING THE PROPOSED DESIGN OF THE PROJECT. 5.IN PAVED AREAS, ROUGH GRADE TO SUBGRADE ELEVATION AND LEAVE THE SITE READY FOR SUB-BASE. 6.SUBGRADE EXCAVATION SHALL BE BACKFILLED IMMEDIATELY AFTER EXCAVATION TO HELP OFFSET ANY STABILITY PROBLEMS DUE TO WATER SEEPAGE OR STEEP SLOPES. WHEN PLACING NEW SURFACE MATERIAL ADJACENT TO EXISTING PAVEMENT, THE EXCAVATION SHALL BE BACKFILLED PROMPTLY TO AVOID UNDERMINING OF EXISTING PAVEMENT. 7.ELEVATIONS SHOWN REPRESENT FINISHED SURFACE GRADES. SPOT ELEVATIONS ALONG CURB & GUTTER REPRESENT THE FLOW LINE UNLESS OTHERWISE NOTED 8.EXCESS MATERIAL, BITUMINOUS SURFACING, CONCRETE ITEMS, ABANDONED UTILITY ITEMS, AND OTHER UNSTABLE MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OFF THE CONSTRUCTION SITE. 9.CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF PAVEMENTS AND CURB AND GUTTER WITH SMOOTH UNIFORM SLOPES THAT PROVIDE POSITIVE DRAINAGE TO COLLECTION POINTS. MAINTAIN A MINIMUM SLOPE OF 1.25% IN ASPHALT PAVEMENT AREAS AND A MINIMUM SLOPE OF 0.50% IN CONCRETE PAVEMENT AREAS. 10.MAINTAIN A MINIMUM SLOPE OF 0.50% ALONG CURB & GUTTER. REVIEW PAVEMENT GRADIENT AND CONSTRUCT "INFALL" CURB WHERE PAVEMENT DRAINS TOWARD THE GUTTER, AND "OUTFALL" CURB WHERE PAVEMENT DRAINS AWAY FROM THE GUTTER. 11.INSTALL A MINIMUM OF 4-INCHES OF AGGREGATE BASE MATERIAL UNDER PROPOSED CONCRETE CURB & GUTTER, SIDEWALKS, AND TRAILS UNLESS OTHERWISE DETAILED. 12.GRADING FOR SIDEWALKS AND ACCESSIBLE ROUTES, INCLUDING CROSSING DRIVEWAYS, SHALL CONFORM TO CURRENT STATE & NATIONAL ADA STANDARDS: ACCESSIBLE RAMP SLOPES SHALL NOT EXCEED 8.3% (1:12). SIDEWALK CROSS-SLOPES SHALL NOT EXCEED 2.0%. LONGITUDINAL SIDEWALK SLOPES SHALL NOT EXCEED 5.0%. ACCESSIBLE PARKING STALLS AND ACCESS AISLES SHALL NOT EXCEED 2.0% IN ANY DIRECTION. A MAXIMUM SLOPE OF 1.50% IS PREFERRED. SIDEWALK ACCESS TO EXTERNAL BUILDING DOORS AND GATES SHALL BE ADA COMPLIANT. NOTIFY ENGINEER IMMEDIATELY IF ADA CRITERIA CANNOT BE MET IN ANY LOCATION PRIOR TO PAVEMENT INSTALLATION. CHANGE ORDERS WILL NOT BE ACCEPTED FOR ADA COMPLIANCE ISSUES. 13.UPON COMPLETION OF LAND DISTURBING ACTIVITIES, RESTORE ADJACENT OFFSITE AREAS DISTURBED BY CONSTRUCTION TO MATCH OR EXCEED THE ORIGINAL CONDITION. LANDSCAPE AREAS SHALL BE RE-VEGETATED WITH A MINIMUM OF 4-INCHES OF TOPSOIL. 14.EXCAVATE DRAINAGE TRENCHES TO FOLLOW PROPOSED STORM SEWER ALIGNMENTS. REFER TO THE UTILITY PLANS FOR LAYOUT AND ELEVATIONS FOR PROPOSED SANITARY SEWER, WATER MAIN, AND OTHER BUILDING UTILITY SERVICE CONNECTIONS. PROPOSED STORM SEWER PROPERTY LINE EXISTING CONTOUR PROPOSED CONTOUR 928 925 PROPOSED SPOT ELEVATION100.00 LEGEND PROPOSED HIGH POINT ELEVATION HP:0.0 PROPOSED LOW POINT ELEVATION PROPOSED GUTTER ELEVATION PROPOSED TOP OF CURB ELEVATION PROPOSED FLUSH PAVEMENT ELEVATION LP:0.0 G:0.00 T:0.00 PROPOSED EMERGENCY OVERFLOW ELEVATION T/G:0.0 EOF:0.0 0.0%PROPOSED DRAINAGE DIRECTION ME:0.0 MATCH EXISTING ELEVATION PROPOSED STORM MANHOLE (SOLID CASTING) PROPOSED STORM MANHOLE (ROUND INLET CASTING) PROPOSED STORM MANHOLE/ CATCH BASIN (CURB INLET CASTING) PROPOSED STORM SEWER CLENOUT PROPOSED RIPRAP PROPOSED FLARED END SECTION CO D PROPOSED RIDGE LINE PROPOSED SWALE PROPOSED GRADE AT TOP/BOTTOM OF WALLTW:0.0 BW:0.0 PR E P A R E D F O R GR A D I N G A N D DR A I N A G E P L A N C500 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 0.00%PROPOSED GRADE BETWEEN POINTS Know what'sbelow. before you dig.Call R NO R T H PR E P A R E D F O R GR A D I N G A N D DR A I N A G E P L A N C500 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN 0 GRAPHIC SCALE IN FEET 20 10 20 40 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S KB P DL E GRADING QUANTITIES RAW CUT (CY)±808 RAW FILL (CY)±8025 NET FILL (CY)±7218 EARTHWORK QUANTITIES ARE PRELIMINARY, SUBJECT TO CHANGE, AND SHOULD NOT BE USED FOR CONTRACTOR QUANTITY TAKEOFF. CALCULATIONS ARE BASED ON EXISTING TOPOGRAPHIC DATA AND ARE SUBJECT TO GEOTECHNICAL GUIDANCE. CALCULATIONS ARE A COMPARISON OF EXISTING TO FINAL GRADE AND DO NOT ACCOUNT FOR PAVEMENT AND OTHER CONSTRUCTION HOLD DOWNS. SHRINK/SWELL FACTORS FROM THE FINAL GEOTECHNICAL REPORT HAVE NOT BEEN INCORPORATED. 73 Item 5. 8 3 4 2 1 5 67 SS T CAR WASH BUILDING 6,200 S.F. 947.00 FFE SS S S S S S G R A N D A V E N U E N E C E N T R A L A V E N U E N E 4 7 T H A V E N U E N E SS S S S S S ST ST S ST ST ST ST ST ST HH HH E ST D D D STMH 02 RE:947.75 IE:940.75 N (4.00' SUMP) CBMH 104 RE:945.58 IE:941.37 N IE:941.12 S STMH 102 RE:945.33 IE:940.91 NW IE:940.91 S (4.00' SUMP) STUB 01 IE:940.75 N CBMH 101 RE:944.99 (4.00' SUMP) CBMH 103 RE:944.98 IE:941.47 N IE:941.47 SE STUB 6 IE:936.50 S STMH 100 RE:943.55 IE:936.50 N IE:938.50 W IE:936.50 W CONNECT TO EXISTING CATCH BASIN IE:936.00 E 28 LF - 12" HDPE @ 2.00% (3.37) 8 LF - 12" HDPE @ 2.00% (3.37) 5 LF - 15" RCP @ 0.00% (5.61) 38 LF - 15" RCP @ 1.32% (4.16) 20 LF - 15" HDPE @ 0.63% (3.15) CO CO SCOCO S SSMH-202 RE:946.33 IE:941.44 W IE:939.13 S IE:937.63 N SANITARY SERVICE IE:942.00 E CONNECT TO TRENCH DRAIN IE:945.78 SW CONNECT TO BUILDING RECLAIM SYSTEM IE:944.00 NE CO-204 RE:946.06 IE:940.31 W IE:940.31 N CO-203 RE:946.20 IE:939.70 W IE:939.70 S IE:939.70 N CONNECTION TO RECLAIM MANHOLE 8 IE:940.41 E CONNECTION TO RECLAIM MANHOLE 6 IE:940.32 E WYE 1 IE:940.21 S IE:940.21 W IE:940.21 N CONNECTION TO RECLAIM MANHOLE 2 IE:939.80 E SSMH-201 RE:946.52 IE:935.27 S IE:935.17 NW CONNECT TO EXISTING MANHOLE RE:939.90 (EXISTING) IE:926.70 W 8" PVC (EXISTING) IE:928.20 SE 28 LF - 6" PVC SDR-35 @ 2.00% 44 LF - 6" PVC SDR-35 @ 5.35% 130 LF - 6" PVC SDR-35 @ 5.35% 5 LF - 6" PVC @ 2.00% 5 LF - 6" PVC @ 2.00% 5 LF - 6" PVC @ 2.00% 5 LF - 6" PVC @ 2.00% 29 LF - 6" PVC SDR-35 @ 2.00% 26 LF - 6" PVC @ 2.00% 36 LF - 4" PVC @ 5.00% NYLOPLAST 106 W/ SOLID COVER RE:946.30 IE:942.37 W IE:941.87 S 65 LF - 12" HDPE @ 0.50% (3.25) 40 LF - 6" PVC @ 2.00% (3.22) 35 LF - 12" HDPE @ 0.50% (3.16) 39 LF - 15" HDPE @ 0.63% (3.81) 38 LF - 6" PVC @ 1.99% (3.85) 40 LF - 6" PVC @ 2.00% (3.25) NYLOPLAST 105 W/ SOLID COVER RE:945.85 IE:941.55 N IE:942.05 W IE:941.55 S WYE A IE:941.00 N IE:941.75 W IE:941.00 S STUB RD-C IE:943.17 E STUB RD-B IE:942.84 E STUB RD-A IE:942.49 E 4" WATER SERVICE 1" COPPER IRRIGATION SERVICE 1" TAP 4"X6" REDUCER 4" GATE VALVE (2) 6" 45° BENDS (2) ROOF DRAINS W/3" PVC (2) ROOF DRAINS W/3" PVC 6" GATE VALVE CONNECT TO EXISTING SERVICE STUB CONTRACTOR TO VERIFY PIPE SIZE 10 . 1 ' PROPOSED GAS SERVICE CONNECT TO EXISTING LINE (FIELD VERIFY SIZE AND LOCATION) PROPOSED UNDERGROUND ELECTRIAL & COMMUNICATIONS CONDUIT CONTRACTOR TO COORDINATE INSTALLATION WITH UTILITY COMPANY 15 LF OF 1" SLOT DRAIN 8000 SERIES, T304 EXISTING HYDRANT EXISTING HYDRANT 6" DIP WATER LINE (2) 6" 45° BENDS (2) 6" 45° BENDSEXISTING 6" C.I.P. WATER MAIN EXISTING 8" PVC SANITARY SEWER EXISTING 30" RCP STORM SEWER EXISTING 30" RCP STORM SEWER EXISTING 18" RCP STORM SEWER EXISTING 8" PVC SANITARY SEWER EXISTING 12" RCP STORM SEWER EXISTING 12" RCP STORM SEWER EXISTING GAS VALVE CBMH 107 RE:945.00 IE:943.07 S 80 LF - 12" HDPE @ 2.00% (0.88) UNDERGROUND DETENTION SYSTEM ADS MC-7200 CHAMBERS OR APPROVED ALTERNATIVE ±10,505 CF STORAGE BOTTOM OF STONE: 936.50 BOTTOM OF CHAMBER: 937.25 TOP OF CHAMBER: 942.25 IF FILL SOIL IS ENCOUNTERED AT THE INTERFACE OF THE STONE AND EARTH, CONTRACTOR TO NOTIFY THE CIVIL ENGINEER. CONTRACTOR TO EXCAVATE TO 5' BELOW BOTTOM OF STONE ELEVATION OR UNTIL NATIVE SOIL IS ENCOUNTERED, WHICHEVER OCCURS FIRST, AND PROVIDE CLEAN SAND IN PLACE OF FILL. CO PROPOSED TRANSFORMER 26 LF - 12" HDPE @ 0.50% (2.94) 24 LF - 12" HDPE @ 0.50% (1.56) NYLOPLAST 100B RE:941.38 IE:938.75 S CO 100A RE:942.75 IE:938.63 N IE:938.63 E Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 6 - U T I L I T Y P L A N . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 6 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N SANITARY SEWER MANHOLE SANITARY SEWER WATERMAIN GATE VALVE HYDRANT TEE REDUCER UNDERGROUND ELECTRIC COMMUNICATIONS GAS MAIN STORM SEWER LEGEND CO S SANITARY CLEANOUTCO S EXISTING PROPOSED DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 UTILITY PLAN NOTES 1.INSTALL UTILITIES IN ACCORDANCE WITH APPLICABLE CITY SPECIFICATIONS, STATE PLUMBING CODE, AND BUILDING PERMIT REQUIREMENTS. 2.CONTACT STATE 811 CALL-BEFORE-YOU-DIG LOCATING SERVICE AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATION FOR UNDERGROUND UTILITY LOCATIONS. 3.CONTRACTOR IS RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL. 4.SANITARY SEWER PIPE SHALL BE: PVC SDR 26: ASTM D-3034 PVC SDR 35: ASTM D-3034 PVC SCH 40: ASTM D-2665 SANITARY SEWER FITTINGS SHALL BE: PVC SDR 26: ASTM D-3212, F-477 PVC SDR 35: ASTM D-3212, F-477 PVC SCH 40: ASTM D1784, D-2665 5.WATER MAIN PIPE SHALL BE: PVC: AWWA C-900 DUCTILE IRON: ASTM A536, AWWA C-150 WATER MAIN FITTINGS SHALL BE: PVC:F-1970, AWWA C-907 DUCTILE IRON: ASTM A674, AWWA C-153, C-105, C-110, C-111 5.STORM SEWER PIPE SHALL BE: RCP: ASTM C-76, ASTM C-361 HDPE: ASTM F-2306 PVC SEWER & DRAIN PIPE: ASTM D-2729 PVC SCH40: ASTM D-1784, D-2665 DRAIN TILE SHALL BE: PVC: ASTM D-2729 STORM SEWER FITTINGS SHALL BE: RCP: ASTM C-76, JOINTS PER ASTM C-361, C-990, AND C-443 HDPE: ASTM D-3212, F-2306 PVC: ASTM D-2729, JOINTS PER ASTM D-3212 PVC SCH40: ASTM D-2665 6.WHEN CONNECTING TO AN EXISTING UTILITY LINE, FIELD VERIFY THE LOCATION, DEPTH, AND SIZE OF THE EXISTING PIPE(S) PRIOR TO INSTALLATION OF THE NEW LINES. NOTIFY THE PROJECT ENGINEER OF ANY DISCREPANCIES OR VARIATIONS IMPACTING THE PROPOSED DESIGN OF THE PROJECT. 7.PLACE AND COMPACT ALL FILL MATERIAL PRIOR TO INSTALLATION OF PROPOSED UNDERGROUND UTILITIES. MINIMUM TRENCH WIDTH SHALL BE 2 FEET. 8.MAINTAIN A MINIMUM OF 7'-6" COVER ON ALL WATER LINES. 9.FOR WATER LINES AND STUB-OUTS UTILIZE MECHANICAL JOINTS WITH RESTRAINTS SUCH AS THRUST BLOCKING, WITH STAINLESS STEEL OR COBALT BLUE BOLTS, OR AS INDICATED IN THE CITY SPECIFICATIONS AND PROJECT DOCUMENTS. 10.MAINTAIN 18-INCH MINIMUM VERTICAL SEPARATION WHERE SEWER PIPE CROSSES WATER LINES (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE OR STRUCTURE). PROVIDE 10-FOOT HORIZONTAL SEPARATION BETWEEN SEWER PIPE AND WATER LINES. 11.IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM LINES AND GAS LINES (OR ANY OBSTRUCTION EXISTING AND PROPOSED), THE SANITARY PIPE MATERIAL SHALL BE PVC SCHEDULE 40 OR PVC C900 AND HAVE MECHANICAL JOINTS AT LEAST 10 FEET ON EITHER SIDE OF THE CENTER LINE OF THE CROSSING. THE WATER LINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE FASTENERS AS REQUIRED TO PROVIDE A MINIMUM OF 18-INCH VERTICAL SEPARATION MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11 (AWWA C-151) (CLASS 50). 12.ALL PVC & HDPE SEWER AND WATER PIPE SHALL HAVE A TRACER WIRE INSTALLED IN THE TRENCH AND TERMINATED PER THE DETAILS. 13.UNDERGROUND UTILITY LINES SHALL BE INSTALLED, INSPECTED AND APPROVED PRIOR TO PLACING BACKFILL. 14.IN PAVEMENT AREAS, RAISE MANHOLE CASTINGS TO BE FLUSH WITH PROPOSED FINISHED SURFACE GRADE. IN GREEN AREAS, RAISE MANHOLE CASTINGS TO BE ONE FOOT ABOVE FINISHED GROUND ELEVATION & INSTALL A WATERTIGHT LID. 15.REFER TO PLUMBING PLANS FOR LOCATION, SIZE AND ELEVATION OF UTILITY SERVICE CONNECTIONS AND ROOF DRAINS TO THE INTERIOR BUILDING SYSTEMS. BACKFLOW DEVICES (DDCV AND PRZ ASSEMBLIES) & METERS ARE LOCATED INSIDE THE BUILDING. 16.CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 17.CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES. COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. 18.REFER TO THE SITE ELECTRICAL PLANS FOR SPECIFICATIONS OF THE PROPOSED SITE LIGHTING AND ELECTRICAL EQUIPMENT. 19.EXCAVATE DRAINAGE TRENCHES TO FOLLOW PROPOSED STORM SEWER ALIGNMENTS. REFER TO THE UTILITY PLANS FOR LAYOUT AND ELEVATIONS FOR PROPOSED SANITARY SEWER, WATER MAIN, AND OTHER BUILDING UTILITY SERVICE CONNECTIONS. REFER TO THE GRADING PLAN FOR DETAILED SURFACE ELEVATIONS. 20.EXCESS MATERIAL, ABANDONED UTILITY ITEMS, AND OTHER UNUSABLE MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OFF THE CONSTRUCTION SITE. 21.COORDINATE WITH THE PLUMBING PLANS FOR THE LOCATION, SIZE AND ELEVATION OF THE PROPOSED UNDERGROUND ROOF DRAIN CONNECTIONS. 22.WHERE STORM SEWER ROOF DRAINS HAVE LESS THAN 4-FEET OF COVER IN PAVED AREAS OR 3-FEET OF COVER IN LANDSCAPE AREAS, PROVIDE 3-INCH THICK INSULATION A MINIMUM OF 5-FEET IN WIDTH, CENTERED ON THE PIPE. 23.ALL STORM SEWER PIPE JOINTS SHALL BE WATER-TIGHT CONNECTIONS. 24.ALL STORM SEWER PIPE CONNECTIONS TO MANHOLES SHALL BE GASKETED AND WATER TIGHT. BOOTED COUPLERS AT THE STRUCTURE OR A WATER STOP WITH NON-SHRINK GROUT MAY BE USED IN ACCORDANCE WITH LOCAL CODES. 25.CONTRACTOR SHALL AIR TEST ALL STORM SEWER PIPE IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. Know what'sbelow. before you dig.Call NO R T H PR E P A R E D F O R UT I L I T Y P L A N C600 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN 0 GRAPHIC SCALE IN FEET 20 10 20 40 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S KB P DL E 74 Item 5. PR E P A R E D F O R UT I L I T Y D E T A I L S C601 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 6 - U T I L I T Y D E T A I L S . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 7 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S KB P DL E 75 Item 5. NO SCALE DRAIN TILE3 4" PERFORATED DRAIN TILE WASHED ROCK GEOTEXTILE NON-WOVEN FABRIC SECTION A-A FORM 1/2 PIPE SECTION OF LARGEST DIAMETER PIPE GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN BY ARROWS VARIABLE 3" 64" 3" 5" 48" 48" 27" 16" O. C . 16" NOTE: MANHOLE INVERT SHALL BE SLOPED TO PROVIDE SMOOTH FLOW FROM INLET TO OUTLET. CONCRETE ADJUSTING RINGS (2") 2 MIN., MAX. 4 MIN. 1/4" MORTAR BETWEEN CASTING, RINGS & STRUCTURE. MORTAR SHALL MEET WISDOT SPEC. 519 PRECAST ECCENTRIC CONE NO SCALE ECCENTRIC SANITARY MANHOLE 2 NEOPRENE WATERPROOF GASKETS REQUIRED FOR PIPE INSERTS WALLS TO BE CONSTRUCTED OF PRECAST SECTIONS. JOINTS SHALL BE CONSTRUCTED WITH CONFINED O-RING GASKETS. STEPS SHALL BE EXTRUDED STEEL REINFORCED COPOLYMER PLASTIC AS MANUFACTURED BY M.A. INDUSTRIES INC. 6" BASE FOR ALL MANHOLES LESS THAN 14 FT. DEEP INCREASE BASE 2" PER 6 FT. OF DEPTH BEYOND 14 FT. 5" PRECAST BASE MAY BE USED FOR MANHOLES LESS THAN 14 FT. DEEP. ALL INTERIOR JOINTS SHALL BE GROUTED TO A SMOOTH FINISH VARIES FLOW 4" 8" AS NOTED ON PLANS 16 " O. C . CONCRETE ADJUSTING RINGS (2") MIN., MAX. 4 MIN. 1/4" MORTAR BETWEEN CASTING, RINGS & STRUCTURE. MORTAR SHALL MEET WISDOT SPEC 519 STEPS SHALL BE EXTRUDED STEEL REINFORCED COPOLYMER PLASTIC AS MANUFACTURED BY M.A. INDUSTRIES INC. WALLS TO BE PRECAST SECTION BASES SHALL BE 6" PRECAST W/2" LEAN GROUT OR 8" POURED SLAB. NOTE: MANHOLE INVERT SHALL BE SLOPED TO PROVIDE SMOOTH FLOW FROM INLET TO OUTLET. GROUT PERIMETER OF MANHOLE SLAB TOP 24" x 36" PRE-CAST OPENING AS REQUIRED DIA. "D" 48" 60" 66" 72" "C" COVER 58" 72" 79" 86" THICKNESS 8" 8" 8" "T" 6" C.L. "A" B.C. TO 24" 27" 21" 15" 12" TOP SECTION REQUIRED B.C. TO C.L. "A" 35" 45" 39" 48" "T" THICKNESS 8" 12" 8" 12" COVER "C" 144" 126" 114" 100" "D" DIA. 120" 108" 96" 84" NO SCALE CATCHBASIN STORM MANHOLE1 4' - 0 " S U M P (P E R P L A N ) CASTING AND ADJUSTING RINGS Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 6 - U T I L I T Y D E T A I L S . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 7 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N PR E P A R E D F O R UT I L I T Y D E T A I L S C602 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 1'-0" 6" 6" THICK CONC. COLLAR (TYP.) NEENAH R-3067-V, R-3067-VB, OR R-1642 W/TYPE C LID NEENAH R-1642 W/TYPE C LID DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S KB P DL E 76 Item 5. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ C 6 - U T I L I T Y D E T A I L S . d w g J u l y 0 1 , 2 0 2 6 - 5 : 1 7 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N PR E P A R E D F O R UT I L I T Y D E T A I L S C603 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A H E I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L EN G I N E E R U N D E R T H E L A W S O F T H E S T A T E O F MI N N E S O T A . MN LI C . N O . MA T T S C H W A R T Z 06 / 0 1 / 2 0 2 6 63 4 1 5 (STMH-100) OUTLET CONTROL STRUCTURE 15" OUTLET PIPE IE: 936.50 STORMTECH END CAP STONE IE: 936.5 TOP CHAMBER: 942.25 TOP STONE : 943.25 RECHARGE VOLUME DEPTH IE: 938.46 WQV PROVIDED 3,222 CF CHAMBER IE : 937.25 BMP 1 - TYPICAL SECTION - ADS STORMTECH MC-7200 - FILTRATION PROVIDE GEOTEXTILE FABRIC AROUND PERIMETER OF STONE AND SAND PER ADS REQUIREMENTS PROVIDE GEOTEXTILE FABRIC AROUND PERIMETER OF STONE AND SAND PER ADS REQUIREMENTS STONE TO MEET ADS STORMTECH MANUFACTURED RECOMMENDATIONS, NO LIMESTONE (OR RECYCLED CONCRETE) MATERIAL IS ALLOWED, BENEATH, BETWEEN OR IMMEDIATELY ON TOP OF THE CHAMBER SYSTEM PRE-CAST WEIR WALL WITH MANHOLE STRUCTURE UPSTREAM SIDE OF WEIR WALL DOWNSTREAM SIDE OF WEIR WALL 15" INLET 15" OUTLET STMH-100 PLAN VIEW PRECAST WEIR WALL, TOP WALL EL: 942.00 3"x6" ORIFICE EL: 938.46 PROVIDE NON-WOVEN GEOTEXTILE FABRIC AROUND PERIMETER OF STONE AND SAND PER ADS REQUIREMENTS 4"x6" ORIFICE EL: 938.80 6"x6" ORIFICE EL: 939.70 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N ML S KB P DL E 77 Item 5. LANDSCAPE LEGEND EXISTING DECIDUOUS TREE (TYP.) EDGER (TYP.) APPROXIMATE LIMITS OF SOD/IRRIGATION, SOD ALL DISTURBED AREAS (TYP.) ROCK MULCH (TYP.) SOD (TYP.) A LANDSCAPE KEYNOTES EDGER (TYP.) DOUBLE SHREDDED HARDWOOD MULCH (TYP.) ROCK MULCH (TYP.) SOD (TYP.) B C D SS S S S SS S S S ST ST ST ST ST HH E ST SS S S S SS S S S ST ST ST ST ST HH E ST 8 3 4 2 1 5 67 SS T CAR WASH BUILDING 6,200 S.F. 947.00 FFE STATE TRUNK HWY 65 (CENTRAL AVENUE NE) 47 T H A V E N E D CO SCOCO S D D C O CO D D D A B B B B B B B A B A B C C B B D D CO 2' LANDSCAPING WALL, SEE SEE CIVIL 30' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 10' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 40' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 10' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION 30' DRAINAGE AND UTILITY EASEMENT PER THE PLAT OF GRAND CENTRAL LOFTS 3RD ADDITION UNDERGROUND STORM STRUCTURE, SEE UTILITIES EXISTING PROPERTY LINE PROPOSED PROPERTY LINE PYLON SIGN, SEE CIVIL SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CAL HT CONIFEROUS TREE CSP 3 CHALET SWISS STONE PINE PINUS CEMBRA 'CHALET'B & B 6` HT. OVERSTORY TREE BRM 3 BRANDYWINE RED MAPLE ACER RUBRUM 'BRANDYWINE'B & B 2.5" CAL. GSG 4 GOLDSPIRE GINKGO TREE GINKGO BILOBA 'BLAGON'B & B 2.5" CAL. STL 3 SENTRY® LINDEN TILIA AMERICANA 'MCKSENTRY'B & B 2.5" CAL. VFE 3 VALLEY FORGE ELM ULMUS AMERICANA 'VALLEY FORGE'B & B 2.5" CAL. SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SPACING CONIFEROUS SHRUBS ELU 14 EVERLOW YEW TAXUS X MEDIA 'EVERLOW'#5 CONT.4` O.C. MJJ 29 MINT JULEP® JUNIPER JUNIPERUS CHINENSIS 'MONLEP'#5 CONT.5` O.C. SGJ 21 SEA GREEN JUNIPER JUNIPERUS CHINENSIS 'SEA GREEN'#5 CONT.5` O.C. TCA 5 TECHNY ARBORVITAE THUJA OCCIDENTALIS 'TECHNY'#5 CONT.6' O.C. DECIDUOUS SHRUBS AMC 9 AUTUMN MAGIC BLACK CHOKEBERRY ARONIA MELANOCARPA 'AUTUMN MAGIC'#5 CONT.4` O.C. DSC 19 DAKOTA SUNSPOT® BUSH CINQUEFOIL DASIPHORA FRUTICOSA 'FARGO'#5 CONT.3` O.C. FDD 14 FIREDANCE™ DOGWOOD CORNUS SERICEA 'BAILADELINE'#5 CONT.4` O.C. KOH 16 KODIAK® ORANGE HONEYSUCKLE DIERVILLA X 'G2X88544'#5 CONT.4` O.C. KOR 13 CORAL KNOCK OUT® ROSE ROSA X 'RADRAL'#5 CONT.3` O.C. MFS 9 MATCHA BALL® FALSE SPIRAEA SORBARIA SORBIFOLIA 'LEVGREEN'#5 CONT.4` O.C. ORNAMENTAL GRASSES KFG 41 KARL FOERSTER FEATHER REED GRASS CALAMAGROSTIS X ACUTIFLORA 'KARL FOERSTER'#1 CONT.2.5` O.C. NSG 26 NORTHWIND SWITCH GRASS PANICUM VIRGATUM 'NORTHWIND'#1 CONT.2.5` O.C. PDS 85 PRAIRIE DROPSEED SPOROBOLUS HETEROLEPIS #1 CONT.2` O.C. PERENNIALS AJS 76 AUTUMN JOY STONECROP HYLOTELEPHIUM X 'HERBSTFREUDE'#1 CONT.18" O.C. BIB 45 BLUE ICE BLUESTAR AMSONIA X 'BLUE ICE'#1 CONT.18" O.C. CRS 71 CRAZYBLUE RUSSIAN SAGE SALVIA YANGII 'CRAZYBLUE'#1 CONT.24" O.C. MOO 81 MILLENIUM ORNAMENTAL ONION ALLIUM X 'ALLMIG1'#1 CONT.18" O.C. MSY 69 MOONSHINE YARROW ACHILLEA X 'MOONSHINE'#1 CONT.18" O.C. OCB 45 OBSIDIAN CORAL BELLS HEUCHERA X 'OBSIDIAN'#1 CONT.18" O.C. PLANT SCHEDULE Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ L 1 - L A N D S C A P E P L A N . D W G J u l y 0 1 , 2 0 2 6 - 5 : 1 8 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N REQUIRED FRONTAGE TREES - HIGHWAY 65:6 TREES = 260 L.F. FRONTAGE / 50 PROVIDED FRONTAGE TREES - HIGHWAY 65:6 TREES = 4 PROPOSED TREES (PLACED ELSEWHERE ON SITE DUE TO SITE CONSTRAINTS) + 2 EXISTING TREES REQUIRED FRONTAGE TREES - GRAND AVENUE:6 TREES = 278 L.F. FRONTAGE / 50 PROVIDED FRONTAGE TREES - GRAND AVENUE:6 TREES REQUIRED FRONTAGE TREES - 47TH AVENUE NE:3 TREES = (209 L.F. FRONTAGE - 30 L.F. DRIVEWAY - 30 L.F. DRIVEWAY) / 50 PROVIDED FRONTAGE TREES - 47TH AVENUE NE:3 TREES REQUIRED PARKING LOT TREES:1 TREE = 13 PARKING SPACES / 20 PROVIDED PARKING LOT TREES:1 TREE REQUIRED PARKING LOT SCREENING:A 5'+ WIDE LANDSCAPED FRONTAGE STRIP ALONG PUBLIC STREET OR SIDEWALK. PROVIDED PARKING LOT SCREENING:A 5'+ WIDE LANDSCAPED FRONTAGE STRIP PLANTED WITH SHRUBS/ORNAMENTAL GRASSES ALONG PUBLIC STREET OR SIDEWALK. LANDSCAPE SUMMARY PR E P A R E D F O R LA N D S C A P E P L A N L100 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A HE I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L LA N D S C A P E A R C H I T E C T U N D E R T H E L A W S O F TH E S T A T E O F M I N N E S O T A . MN LI C . N O . CL A R E F . K I B O K O , P L A 06 / 0 1 / 2 0 2 6 64 5 2 8 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N AT K AT K CF K NOTE: QUANTITIES ON PLAN SUPERSEDE LIST QUANTITIES IN THE EVENT OF A DISCREPANCY. ABBREVIATIONS: B&B = BALLED AND BURLAPPED CAL. = CALIPER HT. = HEIGHT MIN. = MINIMUM O.C. = ON CENTER SP. = SPECIES QTY. = QUANTITY Know what'sbelow. before you dig.Call NO R T H 0 GRAPHIC SCALE IN FEET 201020 40 TOTAL REQUIRED TREES:16 TREES TOTAL PROPOSED TREES:17 TREES 78 Item 5. Th i s d o c u m e n t , t o g e t h e r w i t h t h e c o n c e p t s a n d d e s i g n s p r e s e n t e d h e r e i n , a s a n i n s t r u m e n t o f s e r v i c e , i s i n t e n d e d o n l y f o r t h e s p e c i f i c p u r p o s e a n d c l i e n t f o r w h i c h i t w a s p r e p a r e d . R e u s e o f a n d i m p r o p e r r e l i a n c e o n t h i s d o c u m e n t w i t h o u t w r i t t e n a u t h o r i z a t i o n a n d a d a p t a t i o n b y K i m l e y - H o r n a n d A s s o c i a t e s , I n c . s h a l l b e w i t h o u t l i a b i l i t y t o K i m l e y - H o r n a n d A s s o c i a t e s , I n c . SHEET NUMBER K: \ T W C _ L D E V \ C r e w C a r w a s h \ C o l u m b i a H e i g h t s \ 3 D e s i g n \ C A D \ P l a n S h e e t s \ L 1 - L A N D S C A P E D E T A I L S . D W G J u l y 0 1 , 2 0 2 6 - 5 : 1 8 p m BY RE V I S I O N S No . DA T E 2 0 2 6 K I M L E Y - H O R N A N D A S S O C I A T E S , I N C . 76 7 E U S T I S S T R E E T , S U I T E 1 0 0 , S T . P A U L , M N 5 5 1 1 4 PH O N E : 6 5 1 - 6 4 5 - 4 1 9 7 WW W . K I M L E Y - H O R N . C O M IS S U E D F O R R E V I E W - N O T F O R C O N S T R U C T I O N DOUBLE SHREDDED HARDWOOD MULCH NOTES: 2X ROOT BALL WIDTH PREPARED PLANTING BED AND BACKFILL SOIL (THOROUGHLY LOOSENED) NOTES: 1.SCARIFY SIDES AND BOTTOM OF HOLE. 2.PROCEED WITH CORRECTIVE PRUNING OF TOP AND ROOT. 3.REMOVE CONTAINER AND SCORE OUTSIDE OF SOIL MASS TO REDIRECT AND PREVENT CIRCLING FIBROUS ROOTS. REMOVE OR CORRECT STEM GIRDLING ROOTS. 4.PLUMB AND BACKFILL WITH PLANTING SOIL. 5.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANTS AND FILL VOIDS. 6.BACK FILL VOIDS AND WATER SECOND TIME. 7.PLACE MULCH WITHIN 48 HOURS OF THE SECOND WATERING UNLESS SOIL MOISTURE IS EXCESSIVE. 8.MIX IN 3-4" OF ORGANIC COMPOST. 1.SCARIFY SIDES AND BOTTOM OF HOLE. 2.PROCEED WITH CORRECTIVE PRUNING. 3.SET PLANT ON UNDISTURBED NATIVE SOIL OR THOROUGHLY COMPACTED PLANTING SOIL. INSTALL PLANT SO THE ROOT FLARE IS AT OR UP TO 2" ABOVE THE FINISHED GRADE WITH BURLAP AND WIRE BASKET, (IF USED), INTACT. 4.SLIT REMAINING TREATED BURLAP AT 6" INTERVALS. 5.BACKFILL TO WITHIN APPROXIMATELY 12" OF THE TOP OF THE ROOTBALL, THEN WATER PLANT. REMOVE THE TOP 1/3 OF THE BASKET OR THE TOP TWO HORIZONTAL RINGS WHICHEVER IS GREATER. REMOVE ALL BURLAP AND NAILS FROM THE TOP 1/3 OF THE BALL. REMOVE ALL TWINE. REMOVE OR CORRECT STEM GIRDLING ROOTS. 6.PLUMB AND BACKFILL WITH PLANTING SOIL. 7.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANTS AND FILL VOIDS. 8.BACK FILL VOIDS AND WATER SECOND TIME. 9.PLACE MULCH WITHIN 48 HOURS OF THE SECOND WATERING UNLESS SOIL MOISTURE IS EXCESSIVE. 10.FINAL LOCATION OF TREE TO BE APPROVED BY OWNER. PLANTING SOIL AS SPECIFIED ON CENTER SPACING PER PLANT SCHEDULE. EXTEND HOLE EXCAVATION WIDTH A MINIMUM OF 6" BEYOND THE PLANTS ROOT SYSTEM. FINISHED GRADE EDGER, AS SPECIFIED .. . . . .. . . . . . . . .. . . . . . . . . . .. . . . . . . . . . . . ... . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . .. . . . . . . . . . .. . . . .. . .. . . . TREE PLANTING DETAIL SCALE: N.T.S.L1011 SHRUB / PERENNIAL PLANTING DETAIL SCALE: N.T.S.L1012 MULCH 3/16" X 5" STEEL EDGER 12" STEEL EDGER SPIKE TURF/SOD SUBGRADE 12" STEEL EDGER SPIKE 3/16" X 5" STEEL EDGER 4' MULCH TURF/SOD TOP OF EDGER TO BE FLUSH WITH SOD PLANSECTION STEEL EDGER DETAIL SCALE: N.T.S.L1013 PLANTING 1.CONTACT COMMON GROUND ALLIANCE AT 811 OR CALL811.COM TO VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF ANY PLANTS OR LANDSCAPE MATERIAL. 2.ACTUAL LOCATION OF PLANT MATERIAL IS SUBJECT TO FIELD AND SITE CONDITIONS. 3.NO PLANTING WILL BE INSTALLED UNTIL ALL GRADING AND CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA. 4.ALL SUBSTITUTIONS MUST BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO SUBMISSION OF ANY BID AND/OR QUOTE BY THE LANDSCAPE CONTRACTOR. 5.PROVIDE TWO YEAR GUARANTEE OF ALL PLANT MATERIALS. THE GUARANTEE BEGINS ON THE DATE OF THE LANDSCAPE ARCHITECT'S OR OWNER'S WRITTEN ACCEPTANCE OF THE INITIAL PLANTING. REPLACEMENT PLANT MATERIAL SHALL HAVE A ONE YEAR GUARANTEE COMMENCING UPON PLANTING. 6.ALL PLANTS TO BE SPECIMEN GRADE, MINNESOTA-GROWN AND/OR HARDY. SPECIMEN GRADE SHALL ADHERE TO, BUT IS NOT LIMITED BY, THE FOLLOWING STANDARDS: ALL PLANTS SHALL BE FREE FROM DISEASE, PESTS, WOUNDS, SCARS, ETC. ALL PLANTS SHALL BE FREE FROM NOTICEABLE GAPS, HOLES, OR DEFORMITIES. ALL PLANTS SHALL BE FREE FROM BROKEN OR DEAD BRANCHES. ALL PLANTS SHALL HAVE HEAVY, HEALTHY BRANCHING AND LEAFING. CONIFEROUS TREES SHALL HAVE AN ESTABLISHED MAIN LEADER AND A HEIGHT TO WIDTH RATIO OF NO LESS THAN 5:3. 7.PLANTS TO MEET AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1-2014 OR MOST CURRENT VERSION) REQUIREMENTS FOR SIZE AND TYPE SPECIFIED. 8.PLANTS TO BE INSTALLED AS PER MNLA & ANSI STANDARD PLANTING PRACTICES. 9.INSTALL PLANTS BY PLANT INSTALLATION PERIOD INFORMATION IN THE LATEST STANDARD PLANTING DETAILS FROM MNDOT. PLANTINGS BEFORE OR AFTER THESE DATES ARE DONE AT RISK. 10.PLANTS SHALL BE IMMEDIATELY PLANTED UPON ARRIVAL AT SITE. PROPERLY HEEL-IN MATERIALS IF NECESSARY; TEMPORARY ONLY. 11.PRIOR TO PLANTING, FIELD VERIFY THAT THE ROOT COLLAR/ROOT FLARE IS LOCATED AT THE TOP OF THE BALLED & BURLAP TREE. IF THIS IS NOT THE CASE, SOIL SHALL BE REMOVED DOWN TO THE ROOT COLLAR/ROOT FLARE. WHEN THE BALLED & BURLAP TREE IS PLANTED, THE ROOT COLLAR/ROOT FLARE SHALL BE EVEN OR SLIGHTLY ABOVE FINISHED GRADE. 12.OPEN TOP OF BURLAP ON BB MATERIALS; REMOVE POT ON POTTED PLANTS; SPLIT AND BREAK APART PEAT POTS. 13.PRUNE PLANTS AS NECESSARY - PER STANDARD NURSERY PRACTICE AND TO CORRECT POOR BRANCHING OF EXISTING AND PROPOSED TREES. 14.WRAP ALL SMOOTH-BARKED TREES - FASTEN TOP AND BOTTOM. REMOVE BY APRIL 1ST. 15.STAKING OF TREES AS REQUIRED; REPOSITION, PLUMB AND STAKE IF NOT PLUMB AFTER ONE YEAR. SOIL 16.THE NEED FOR SOIL AMENDMENTS SHALL BE DETERMINED UPON SITE SOIL CONDITIONS PRIOR TO PLANTING. LANDSCAPE CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT FOR THE NEED OF ANY SOIL AMENDMENTS. 17.BACKFILL SOIL AND TOPSOIL TO ADHERE TO MNDOT STANDARD SPECIFICATION 3877 (LOAM TOPSOIL BORROW) AND TO BE EXISTING TOP SOIL FROM SITE FREE OF ROOTS, ROCKS LARGER THAN ONE INCH, SUBSOIL DEBRIS, AND LARGE WEEDS UNLESS SPECIFIED OTHERWISE. MINIMUM 4" DEPTH TOPSOIL FOR ALL LAWN GRASS AREAS AND 12" DEPTH TOPSOIL FOR TREE, SHRUBS, AND PERENNIALS. MULCH 18.MULCH TO BE AT ALL TREE, SHRUB, PERENNIAL, AND MAINTENANCE AREAS. TREE AND SHRUB PLANTING BEDS SHALL HAVE 4" DEPTH OF DOUBLE SHREDDED HARDWOOD MULCH. DOUBLE SHREDDED HARDWOOD MULCH TO BE USED AROUND ALL PLANTS WITHIN TURF AREAS. PERENNIAL AND ORNAMENTAL GRASS BEDS SHALL HAVE 2" DEPTH DOUBLE SHREDDED HARDWOOD MULCH. MULCH TO BE FREE OF DELETERIOUS MATERIAL AND NATURAL IN COLOR (DYE-FREE), OR APPROVED EQUAL. ROCK MULCH TO BE GRAY TRAP ROCK AT 2-1/2" DIAMETER MINUS, AT MINIMUM 4" DEPTH, OR APPROVED EQUAL. APPLY PRE-EMERGENT HERBICIDE PRIOR TO MULCH PLACEMENT PER MANUFACTURER RECOMMENDATIONS, USE PREEN OR PRE-APPROVED EQUAL. ROCK MULCH TO BE ON COMMERCIAL GRADE FILTER FABRIC, BY TYPAR, OR APPROVED EQUAL WITH NO EXPOSURE. MULCH AND FABRIC TO BE APPROVED BY OWNER PRIOR TO INSTALLATION. MULCH TO MATCH EXISTING CONDITIONS (WHERE APPLICABLE). EDGER 19.EDGING TO BE COMMERCIAL GRADE COL-MET (OR EQUAL) STEEL EDGING; 3/16" THICK x 5" TALL, COLOR BLACK, OR SPADED EDGE, AS INDICATED. STEEL EDGING SHALL BE PLACED WITH SMOOTH CURVES AND STAKED WITH METAL SPIKES NO GREATER THAN 4 FOOT ON CENTER WITH TOP OF EDGER AT GRADE, FOR MOWERS TO CUT ABOVE WITHOUT DAMAGE. UTILIZE CURBS AND SIDEWALKS FOR EDGING WHERE POSSIBLE. WHERE EDGING TERMINATES AT A SIDEWALK, BEVEL OR RECESS ENDS TO PREVENT TRIP HAZARD. SPADED EDGE TO PROVIDE V-SHAPED DEPTH AND WIDTH TO CREATE SEPARATION BETWEEN MULCH AND GRASS. INDIVIDUAL TREE, SHRUB, OR RAIN-GARDEN BEDS TO BE SPADED EDGE, UNLESS NOTED OTHERWISE. EDGING TO MATCH EXISTING CONDITIONS (WHERE APPLICABLE). SEED/SOD 20.ALL DISTURBED AREAS TO BE SODDED, UNLESS OTHERWISE NOTED. SOD TO BE STANDARD MINNESOTA GROWN AND HARDY BLUEGRASS MIX, FREE OF LAWN WEEDS. ALL TOPSOIL AREAS TO BE RAKED TO REMOVE DEBRIS AND ENSURE DRAINAGE. SLOPES OF 3:1 OR GREATER SHALL BE STAKED. SEED AS SPECIFIED, PER MNDOT SPECIFICATIONS AND SUPPLIER/MANUFACTURER RECOMMENDATIONS. IF NOT INDICATED ON LANDSCAPE PLAN, SEE EROSION CONTROL PLAN. IRRIGATION 21.PROVIDE IRRIGATION TO ALL PLANTED AREAS ON SITE. IRRIGATION SYSTEM TO BE DESIGN/BUILD BY LANDSCAPE CONTRACTOR. LANDSCAPE CONTRACTOR TO PROVIDE SHOP DRAWINGS TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION OF IRRIGATION SYSTEM. CONTRACTOR TO PROVIDE OPERATION MANUALS, AS-BUILT PLANS, AND NORMAL PROGRAMMING. SYSTEM SHALL BE WINTERIZED AND HAVE SPRING STARTUP DURING FIRST YEAR OF OPERATION. SYSTEM SHALL HAVE ONE-YEAR WARRANTY ON ALL PARTS AND LABOR. ALL INFORMATION ABOUT INSTALLATION AND SCHEDULING CAN BE OBTAINED FROM THE GENERAL CONTRACTOR. SYSTEM SHALL INCLUDE A RAIN SENSOR AND APPROPRIATE TECHNOLOGY. CONTROLLER TO BE COMMERCIAL GRADE, EPA WATERSENSE APPROVED, CAPABLE OF FLOW SENSING AND OPERATING A MASTER VALVE ON / OFF BY STATION. IRRIGATION SYSTEM TO INCLUDE FLOW SENSOR AND WIRED RAIN / FREEZE SENSOR. PROVIDE MASTER VALVE. THE IRRIGATION SYSTEM SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ZONE PARAMETERS: HEAD-TO-HEAD COVERAGE AND NO SPRAYING OVER WALKS. SEPARATE LAWN ZONES BY MICROCLIMATE- LAWN ON NORTH SIDE OF BUILDING VS LAWN ON SOUTH SIDE OF BUILDING, LAWN ON SLOPE VS LAWN ON LEVEL GRADE. LAWN AREAS TO HAVE MULTI-STREAM ROTARY SPRINKLERS/ SPRAYS/ ROTORS. SHRUB AND PERENNIAL BED AREAS TO HAVE DRIP. TREES IN LAWN AREA TO BE COVERED BY MULTI-STREAM ROTARY SPRINKLERS/ SPRAYS/ ROTORS. TREES IN SHRUBS / PERENNIAL BED AREA TO BE WATERED WITH DRIP IRRIGATION. ALL IRRIGATION HEADS TO BE PRESSURE REGULATED. ESTABLISHMENT 22.PROVIDE NECESSARY WATERING OF PLANT MATERIALS UNTIL THE PLANT IS FULLY ESTABLISHED OR IRRIGATION SYSTEM IS OPERATIONAL. OWNER WILL NOT PROVIDE WATER FOR CONTRACTOR. 23.REPAIR, REPLACE, OR PROVIDE SOD/SEED AS REQUIRED FOR ANY ROADWAY BOULEVARD AREAS ADJACENT TO THE SITE DISTURBED DURING CONSTRUCTION. WARRANTY 24.REPAIR ALL DAMAGE TO PROPERTY FROM PLANTING OPERATIONS AT NO COST TO OWNER. 25.MAINTAIN TREES, SHRUBS, SEED AND OTHER PLANTS UNTIL PROJECT COMPLETION, BUT IN NO CASE, LESS THAN FOLLOWING PERIOD; 1 YEAR AFTER PROJECT COMPLETION. MAINTAIN TREES, SHRUBS, SEED AND OTHER PLANTS BY PRUNING, CULTIVATING, AND WEEDING AS REQUIRED FOR HEALTHY GROWTH. RESTORE PLANTING SAUCERS. TIGHTEN AND REPAIR STAKE AND GUY SUPPORTS AND RESET TREES AND SHRUBS TO PROPER GRADES OR VERTICAL POSITION AS REQUIRED. RESTORE OR REPLACE DAMAGED WRAPPINGS. SPRAY AS REQUIRED TO KEEP TREES AND SHRUBS FREE OF INSECTS AND DISEASE. REPLENISH MULCH TO THE REQUIRED DEPTH. MAINTAIN LAWNS FOR 60 DAYS AFTER INSTALLING SOD INCLUDING MOWING WHEN SOD RECITES 4” IN HEIGHT. WEED PLANTING BEDS AND MULCH SAUCERS AT MINIMUM ONCE A MONTH DURING THE GROWING SEASON. PROVIDE A MONTHLY REPORT TO THE OWNER ON WEEDING AND OTHER MAINTENANCE RESPONSIBILITIES. LANDSCAPE NOTES PR E P A R E D F O R LA N D S C A P E DE T A I L S L101 CR E W C A R W A S H CO L U M B I A H E I G H T S CR E W C A R W A S H CO L U M B I A HE I G H T S MN DA T E : I H E R E B Y C E R T I F Y T H A T T H I S P L A N , SP E C I F I C A T I O N O R R E P O R T W A S P R E P A R E D B Y ME O R U N D E R M Y D I R E C T S U P E R V I S I O N A N D TH A T I A M A D U L Y L I C E N S E D P R O F E S S I O N A L LA N D S C A P E A R C H I T E C T U N D E R T H E L A W S O F TH E S T A T E O F M I N N E S O T A . MN LI C . N O . CL A R E F . K I B O K O , P L A 06 / 0 1 / 2 0 2 6 64 5 2 8 DA T E CH E C K E D B Y SC A L E DE S I G N E D B Y DR A W N B Y KH A P R O J E C T 16 1 0 3 3 0 2 9 07 / 0 1 / 2 0 2 6 AS S H O W N AT K AT K CF K 79 Item 5. THIS SITE IS LOCATED IN A REGION WHERE LIGHTING IS REGULATED BY LOCAL ORDINANCES NOTE: - AREA LIGHTS ON NEW 20 FT. POLES MOUNTED ON 2 FT. CONCRETE BASES - FOOTCANDLE LEVELS CALCULATED AT GRADE USING INITIAL LUMEN VALUES UNLESS NOTED OTHERWISE. CALCULATION SUMMARY LABEL AVG MAX MIN AVG/MIN MAX/MIN CANOPY 63.88 79 42 1.52 1.88 PAVED AREA 15.35 36.9 3.9 3.94 9.46 PROPERTY LINE 1.14 2.8 0.1 11.40 28.00 UNDEFINED 1.51 28.3 0.0 N.A.N.A. LUMINAIRE SCHEDULE SYMBOL QTY LABEL ARRANGEMENT LUMENS LLF BUG RATING WATTS/LUMINAIRE TOTAL WATTS MANUFACTURER CATALOG LOGIC 10 A4 Single 40976 1.040 B3-U0-G5 311.92 3119.2 Lithonia Lighting RSX3 LED P4 50K R4 MVOLT XXX FAO 2 B4 Single 26929 1.040 B2-U0-G4 311.92 623.84 Lithonia Lighting RSX3 LED P4 50K R4 MVOLT HS XXX FAO 8 C2 Single 13028 1.040 B3-U0-G2 78.56 628.48 Lithonia Lighting PCNY LED ALO2 SWW2 (50K) FTL MVOLT (SW. POS. 5) 3 F1 Single 16094 1.040 B5-U0-G1 133.14 399.42 Lithonia Lighting RSXF1 LED P4 50K SP MVOLT IS DNAXD 2 W1 Single 30662 1.040 B3-U0-G4 246.63 493.26 Lithonia Lighting RSX2 LED P6 50K R4 MVOLT XXX FAO 20 W3 Single 5614 1.000 B2-U3-G2 54.5 1090 Luminaire LED SPC8 9OF46IN MIN10 50W 40K MVOLTOP SIL WL LUMINAIRE LOCATION SUMMARY LUM NO.LABEL MTG. HT. 1 A4 22 2 A4 22 3 A4 22 4 A4 22 5 A4 22 6 A4 22 7 A4 22 8 A4 22 9 A4 22 10 A4 22 11 B4 22 12 B4 22 13 C2 10 14 C2 10 15 C2 10 16 C2 10 17 C2 10 18 C2 10 19 C2 10 20 C2 10 21 F1 1 22 F1 1 23 F1 1 24 W1 15 25 W1 15 26 W3 6.47 27 W3 6.47 28 W3 6.47 29 W3 6.47 30 W3 6.47 31 W3 6.47 32 W3 6.47 33 W3 6.47 34 W3 6.47 35 W3 6.47 36 W3 6.47 37 W3 6.47 38 W3 6.47 39 W3 6.47 40 W3 6.47 41 W3 6.47 42 W3 6.47 43 W3 6.47 44 W3 6.47 45 W3 6.47 CAR WASH BUILDING 6,200 S.F. T 4 7 T H A V E N U E N E C E N T R A L A V E N U E N E G R A N D A V E N U E N E 1 A4 2 A4 3 A4 4 A4 5 A4 6 A4 7 A4 8 A4 9 A4 10 A4 11 B4 12 B4 13 C2 14 C2 15 C2 16 C2 17 C2 18 C2 19 C2 20 C2 21 F1 22 F1 23 F1 24 W125 W1 26 W3 27 W3 28 W3 29 W3 30 W3 31 W3 32 W3 33 W3 34 W3 35 W3 36 W3 37 W3 38 W3 39 W3 40 W3 41 W3 42 W3 43 W3 44 W3 45 W3 51 47 46 51 71 66 64 72 66 61 60 67 78 72 70 79 70 65 64 71 73 68 66 74 74 69 67 76 65 61 60 66 69 66 64 71 45 42 42 46 10.2 16.3 21.7 18.9 15.9 15.5 18.3 22.1 19.7 15.9 14.8 16.7 20.8 21.7 20.9 22.3 15.6 16.5 20.3 17.9 12.7 8.2 13.1 18.7 17.0 14.7 13.7 15.0 17.8 16.2 13.6 13.0 14.1 17.4 19.3 22.6 29.5 17.2 14.8 16.9 15.4 12.0 10.2 5.9 9.0 14.2 14.1 12.6 10.8 10.7 11.2 10.9 10.2 10.1 10.5 11.5 14.1 20.8 30.6 16.5 12.0 11.5 11.0 5.1 8.4 14.1 13.6 11.4 8.9 8.8 9.0 8.9 8.5 8.2 8.8 9.7 12.5 19.6 29.6 15.6 11.4 10.7 13.1 8.7 15.3 14.0 11.3 7.7 7.2 7.5 7.9 7.7 7.6 8.1 8.7 11.0 17.3 25.8 14.3 11.2 10.4 18.0 10.4 19.1 16.1 11.7 6.0 6.0 9.1 10.5 8.6 7.1 10.3 11.4 12.8 15.5 18.8 14.0 13.8 11.6 22.0 11.0 21.1 18.7 14.0 5.0 4.5 7.1 4.8 7.7 9.2 13.6 13.6 18.1 4.7 10.3 19.9 21.4 17.5 16.8 15.2 3.9 10.4 21.4 27.9 30.3 28.2 23.5 17.3 16.2 14.6 4.0 10.7 23.5 35.0 36.9 35.8 31.6 19.8 17.3 15.6 11.9 22.4 27.3 20.9 19.9 13.2 24.1 25.0 26.9 18.0 19.1 19.0 16.3 22.3 22.7 15.8 13.8 17.9 17.4 12.9 16.2 17.5 17.8 16.9 20.8 20.0 19.2 23.8 12.3 22.5 20.7 18.3 13.5 14.3 14.8 16.8 21.9 23.7 18.0 14.3 13.2 12.8 12.6 12.8 12.8 13.4 13.6 16.8 16.1 16.3 19.6 9.2 17.1 16.6 16.1 14.6 15.0 17.5 14.4 12.8 13.8 15.1 14.8 14.0 14.4 15.8 17.3 15.3 14.2 15.2 6.8 13.4 14.8 16.7 19.2 17.6 6.0 9.5 11.5 16.1 21.2 19.0 16.7 17.2 20.4 22.9 17.9 14.1 12.4 0.10.10.10.10.10.20.20.30.50.91.31.80.51.81.31.31.92.11.51.00.90.80.50.91.01.32.02.01.51.21.00.40.2 0.2 0.4 1.0 1.6 2.0 2.6 1.8 2.3 2.3 1.1 1.1 2.1 2.4 1.6 1.2 1.4 2.1 0.4 1.9 1.4 1.4 2.0 2.8 2.4 1.5 1.1 1.0 1.0 1.1 1.5 2.2 0.5 1.9 1.1 0.9 0.6 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.2 0.2 0.2 0.2 0.1 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.1 0.3 0.4 0.4 0.4 0.2 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.1 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.5 0.1 0.6 0.6 0.6 0.6 0.2 0.7 0.6 0.6 0.7 0.7 0.7 0.6 0.5 0.4 0.4 0.4 0.5 0.6 0.6 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.6 0.9 0.2 1.0 0.8 0.8 1.1 1.2 1.2 0.9 0.9 1.1 1.3 1.3 1.0 0.7 0.6 0.6 0.6 0.7 1.0 1.2 1.1 0.8 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.9 1.7 0.3 1.8 1.2 1.2 1.8 2.5 2.2 1.4 1.3 1.7 2.6 2.5 1.6 1.2 1.0 1.0 1.0 1.3 1.9 2.6 2.1 1.2 0.9 0.7 0.4 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.9 1.4 2.7 0.6 2.9 2.1 2.1 2.8 3.9 3.3 2.4 2.1 2.7 4.0 4.2 3.1 2.6 2.4 2.4 2.6 2.7 3.2 3.9 3.3 2.1 1.6 1.2 0.7 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.3 0.5 0.8 1.4 2.4 3.8 5.7 8.1 9.8 9.4 8.8 8.8 9.6 11.0 10.2 9.0 8.7 9.1 10.5 11.0 10.4 11.7 10.4 11.4 9.7 9.0 9.2 10.2 9.1 7.1 5.4 3.7 2.0 1.1 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.1 0.1 0.2 0.3 0.7 1.3 2.3 4.1 6.6 9.3 6.3 3.2 1.6 0.9 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.3 0.6 1.3 2.4 4.1 6.0 7.6 3.6 1.8 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.5 1.1 2.1 3.5 4.7 11.2 10.9 9.1 3.8 1.8 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.9 1.8 2.9 3.8 10.4 11.3 11.6 4.1 2.2 1.1 0.6 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.8 1.5 2.4 3.5 5.3 10.5 13.6 14.6 4.9 3.1 1.6 0.8 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.7 1.2 1.9 3.2 5.3 11.6 15.5 16.5 5.8 3.8 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.6 0.9 1.4 2.6 6.1 7.9 6.4 8.3 8.7 9.6 10.9 11.1 7.3 8.0 13.8 15.3 14.6 4.8 2.7 1.5 0.8 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.3 0.4 0.6 0.9 1.8 19.6 14.7 15.1 12.3 4.1 1.7 1.0 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.6 1.3 10.8 3.8 1.3 0.8 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.5 1.2 11.0 3.1 1.2 0.7 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.5 1.5 4.9 28.3 27.7 24.2 19.4 10.5 2.9 1.4 0.7 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.6 2.1 6.5 22.7 9.6 3.8 1.9 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.7 2.2 6.4 18.2 6.7 4.1 0.5 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.7 1.9 4.5 15.0 17.0 19.7 19.8 12.1 4.6 2.7 1.6 0.8 0.4 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.4 0.7 1.6 3.2 13.1 10.4 9.6 8.9 8.0 3.4 2.0 1.2 0.7 0.4 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.6 1.2 2.2 4.9 10.4 13.0 15.7 16.8 15.5 12.0 8.4 7.1 6.3 4.7 7.4 10.5 15.1 18.5 17.8 16.4 16.7 18.7 19.8 16.7 12.6 9.2 5.1 2.5 1.5 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.4 0.6 1.0 2.1 4.8 5.5 5.6 5.6 4.9 3.9 3.6 3.7 3.6 2.2 3.3 3.7 4.7 1.5 5.5 5.2 5.4 5.9 6.4 5.5 4.8 3.9 2.0 1.1 0.8 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.8 2.0 2.4 2.7 3.6 3.1 1.9 1.5 1.5 1.4 1.3 1.3 1.6 2.5 0.6 2.8 2.1 2.1 3.0 3.8 2.8 2.2 1.6 0.8 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.5 1.0 1.2 1.5 1.9 1.8 1.2 0.9 0.9 0.8 0.8 0.8 1.0 1.6 0.4 1.7 1.2 1.3 1.8 2.0 1.7 1.2 0.8 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.7 0.8 0.9 0.9 0.8 0.6 0.6 0.4 0.5 0.6 0.7 0.9 0.3 0.9 0.8 0.8 0.9 0.3 0.9 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.5 0.5 0.5 0.5 0.4 0.4 0.3 0.4 0.4 0.5 0.5 0.2 0.5 0.5 0.5 0.5 0.2 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.3 0.3 0.3 0.3 0.2 0.3 0.3 0.3 0.3 0.2 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.2 0.1 0.2 0.2 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 CREW CARWASH COLUMBIA HEIGHTS, MN SCALE: 1" = 20' D 5/1/26 JAN LAYOUT BY: DWG SIZE:DATE: PROJECT NAME: DRAWING NUMBER:RL-11166-S1-R1 REV.BY DATE DESCRIPTION R1 . . . JAN . . . 6/30/26 . . . REVISED PER UPDATED SITE PLAN . . . 1340 Kemper Meadow Dr, Forest Park, OH 45240 513-574-9500 redleonard.com ANY SITE PLAN(S), FLOOR PLAN(S), RENDERING(S), LIGHTING LAYOUT(S) AND PHOTOMETRIC PLAN(S) INCLUDING BUT NOT LIMITED TO ANY PROJECT(S) CREATED/PRODUCED BY RED LEONARD ASSOCIATES INC., ARE ONLY INTENDED FOR ILLUSTRATION AND QUOTING PURPOSES ONLY. RED LEONARD ASSOCIATES HAS THE RIGHT TO USE THIRD PARTY LASERS, SCANNERS, AND CAMERAS BUT ACTUAL PROJECT CONDITIONS, DIMENSIONS, AND ACCURACY OF MEASUREMENTS MAY DIFFER FROM THESE OR ANY PARAMETERS. RED LEONARD ASSOCIATES INC. ASSUMES NO LIABILITY FOR WHAT IS CREATED/PRODUCED IN THESE RECREATIONS. THIS INCLUDES BUT IS NOT LIMITED TO THE USE OF, INSTALLATION OF AND/OR INTEGRITY OF EXISTING BUILDING(S), SURROUNDING AREA FOR PRODUCT(S) SUCH AS EXISTING POLE(S), ANCHOR BOLT(S), BASE(S), ARCHITECTURAL AND SIGNAGE STRUCTURE(S), LANDSCAPING PLAN(S), LIGHTING PLAN(S), FIXTURE SELECTION(S) AND PLACEMENT, MATERIAL(S), COLOR ACCURACY, TEXTURE(S), AND ANYTHING ATTRIBUTED TO PHOTO REALISM THAT IS CREATED. FURTHERMORE, RED LEONARD ASSOCIATES INC., DOES NOT ASSUME LIABILITY WHATSOEVER FOR ANY PURCHASES MADE BY CLIENT BEFORE, DURING, OR AT THE CONCLUSION OF THE PUBLISHED WORK. THE CUSTOMER, ITS RELATIVE AFFILIATES, AS WELL AS ANY OTHER PERSON(S) IN VIEWING OF THIS PRODUCT IS RESPONSIBLE FOR VERIFYING COMPLIANCE WITH ANY BUT NOT LIMITED TO ALL CODES, PERMITS, RESTRICTIONS, INSTRUCTIONS, PURCHASES, AND INSTALLATIONS OF OBJECTS VIEWED WITHIN THIS DOCUMENT(S) OR PROJECT(S). SYMBOLS ARE NOT DRAWN TO SCALE. SIZE IS FOR CLARITY PURPOSES ONLY. SIZES AND DIMENSIONS ARE APPROXIMATE, ACTUAL MEASUREMENTS MAY VARY. DRAWINGS ARE NOT INTENDED FOR ENGINEERING OR CONSTRUCTION USE. THIS DOCUMENT, ANY RED LEONARD DRAWING(S), OR PROJECT(S) IS NOT TO BE USED AND/OR INTENDED FOR ENGINEERING OR CONSTRUCTION PURPOSES, BUT FOR ILLUSTRATIVE PURPOSES ONLY. ANY LOCATIONS OF EMERGENCY LIGHTING SHOWN WERE PROVIDED BY OTHERS. RED LEONARD ASSOCIATES IS NOT RESPONSIBLE FOR INSUFFICIENT LIGHTING DURING AN EMERGENCY EVENT. ANY USE OF THIS DOCUMENTATION AND/OR OTHER ARTICLES PRODUCED BY RED LEONARD WITHOUT WRITTEN AUTHORIZATION FROM JAYME J. LEONARD IS STRICTLY PROHIBITED. DISCLAIMER 1340 Kemper Meadow Dr, Forest Park, OH 45240 513-574-9500 | redleonard.com 80 Item 5. 83 SF OFFICE 110 208 SF TRAINING 101 1867 SF WASHING AREA 106 1052 SF BLOWER ROOM 105 518 SF ENTRY AREA 111 795 SF MECHANICAL ROOM 103214 SF UTILITY ROOM 104 50 SF TOILET 102 39 SF STORAGE CLOSET 108 303 SF CORRIDOR 100 1 / A 8 0 1 154' - 8" 26' - 8"90' - 0"38' - 0" 39 ' - 1 0 7 / 8 " 26' - 8"100' - 0"28' - 0" 192 SF TRASH ENCLOSURE 115 208 SF EXTERIOR STORAGE 116 39 ' - 1 0 7 / 8 " 1/8" = 1'-0" PRELIMINARY FLOOR PLAN CREW CARWASH, INC PRO2026 04/28/2026 COLUMBIA HEIGHTS, MN ARCHITECTURAL FLOOR PLAN 81 Item 5. T.O. SLAB 100' - 0" B.O. CANOPY 110' - 0" T.O. TOWER 135' - 0" ACM PANEL SYSTEM COLOR: PEWTER MICA CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND 18"x36" NOMINAL LIMESTONE VENEER COLOR: BUFF LIMESTONE VENEER COLOR: BUFF CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND OVERHEAD COILING DOOR COLOR:CLEAR ANODIZED CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND PREFORMED METAL CORNICE COLOR: PEWTER MICA PREFORMED METAL CORNICE COLOR: PEWTER MICA 4"x16"x24" NOMINAL LIMESTONE VENEER COLOR: BUFF T.O.PAR 120' - 0" CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND STAINLESS STEEL DOOR AND GLAZING CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND 18"x36" NOMINAL LIMESTONE VENEER COLOR: BUFF TOWER (BEYOND) PREFORMED METAL COPING COLOR: PEWTER MICA T.O. SLAB 100' - 0" T.O. PAR. 120' - 0" B.O. CANOPY 110' - 0" T.O. TOWER 135' - 0" OVERHEAD SUPPORTED CANOPY COLOR: PEWTER MICA OVERHEAD COILING DOOR COLOR: CLEAR ANODIZED CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND ACM PANEL SYSTEM COLOR: PEWTER MICA ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED OVERHEAD SUPPORTED CANOPY COLOR: PEWTER MICA 18"x36" NOMINAL LIMESTONE VENEER COLOR: BUFFLIMESTONE VENEER COLOR: BUFF CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND CONCRETEMASONRY UNITS COLOR: BRANDYWINE BLEND PREFORMED METAL CORNICE COLOR: PEWTER MICA PERFORMED METAL CORNICE COLOR: PEWTER MICA 4"x16"x24" NOMINAL LIMESTONE VENEER COLOR: BUFF STAINLESS STEEL DOOR AND GLAZING 1/8" = 1'-0" CREW CARWASH - BUILDING ELEVATIONS CREW CARWASH, INC PRO2026 04/28/2026 COLUMBIA HEIGHTS, MN SOUTH ELEVATION NORTH ELEVATION 82 Item 5. T.O. SLAB 100' - 0" B.O. CANOPY 110' - 0" T.O. TOWER 135' - 0" OVERHEAD SUPPORTED CANOPY COLOR: PEWTER MICA PREFORMED METAL COPING COLOR: PEWTER MICA OVERHEAD SUPPORTED CANOPY COLOR: PEWTER MICA DECORATIVE WALL SCONCE (TYP.) PREORMED METAL CORNICE COLOR: PEWTER MICA PREORMED METAL CORNICE COLOR: PEWTER MICA CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED HOLLOW METAL FRAMED & INSULTED DOOR FINISHED STAINLESS STEEL ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED PREORMED METAL CORNICE COLOR: PEWTER MICA ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED T.O.PAR 120' - 0" 18"x36" NOMINAL LIMESTONE VENEER COLOR: BUFF 4"x16"x24" NOMINAL LIMESTONE VENEER COLOR: BUFF OVERHEAD SUPPORTED CANOPY COLOR: PEWTER MICA DECORATIVE WALL SCONCE(TYP.) 4"x16"x24" NOMINAL LIMESTONE VENEER COLOR: BUFF CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND EXTERIOR HOLLOW METAL DOOR & FRAME TRASH ENCLOSURE GATE TO BE TREX BOARDS. COLOR: PEBBLE GREY 18"x36" NOMINAL LIMESTONE VENEER COLOR: BUFF CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND T.O. SLAB 100' - 0" B.O. CANOPY 110' - 0" T.O. TOWER 135' - 0" PREORMED METAL CORNICE COLOR: PEWTER MICA CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED OVERHEAD SUPPORTED CANOPY COLOR PEWTER MICA PREFORMED METAL COPING COLOR: PEWTER MICA OVERHEAD SUPPORTED CANOPY COLOR: PEWTER MICA DECORATIVE WALL SCONCE (TYP.) PREFORMED METAL CORNICE COLOR: PEWTER MICA OVERHEAD SUPPORTED CANOPY COLOR: PEWTER MICA ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND ALUMINUM STOREFRONT AND GLAZING SYSTEM COLOR: CLEAR ANODIZED T.O.PAR 120' - 0" PREORMED METAL CORNICE COLOR: PEWTER MICA HOLLOW METAL FRAMED & INSULATED DOOR FINISHED STAINLESS STEEL CONCRETE MASONRY UNITS COLOR: BRANDYWINE BLEND 18"x36" NOMINAL LIMESTONE VENEER COLOR: BUFF 4"x16"x24" NOMINAL LIMESTONE VENEER COLOR: BUFF DECORATIVE WALL SCONCE (TYP.) 18"x36" NOMINAL LIMESTONE VENEER COLOR: BUFF 4"x16"x24" NOMINAL LIMESTONE VENEER COLOR: BUFF 1/8" = 1'-0" CREW CARWASH - BUILDING ELEVATIONS CREW CARWASH, INC PRO2026 04/28/2026 COLUMBIA HEIGHTS, MN WEST ELEVATION EAST ELEVATION 83 Item 5. CREW CARWASH - 3D VIEWS CREW CARWASH, INC PRO2026 04/28/2026 COLUMBIA HEIGHTS, MN 84 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 1 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 June 2026 Ursula Brandt City Planner City of Columbia Heights 3989 Central Avenue NE Columbia Heights, MN 55421 Subject: Crew Carwash – Sound Study 47th Avenue, Columbia Heights, MN 55421 Executive Summary This sound study is for the proposed Crew Carwash facility to be constructed on approximately 1.23 acres in Columbia Heights, Minnesota (the project). The project will be located northeast of the Central Avenue and 47th Avenue Northeast intersection. The original project layout included 16 blower units within the carwash building and 10 outdoor vacuum generators which represent the primary noise sources evaluated. The existing noise environment is characterized by traffic, commercial activity, and other typical community noise sources. A total of 17 noise-sensitive receptors were identified as close as 40 feet from the project site, including residential buildings, a hotel, a playground, and restaurant patios. SoundPLAN was used to model normal project operations. Based on the modeling results, 13 of the 17 receptors would exceed the Minnesota Pollution Control Agency (MPCA) daytime L50 noise thresholds without noise mitigation. To comply with MPCA thresholds, Kimley-Horn recommends Crew Carwash reconfigure and reduce vacuum units, add a noise wall between the vacuum units and sensitive receptors to the south, and install a sound deadening room at the outlet of the carwash tunnel. Project Description The carwash project will be constructed on approximately 1.23 acres of undeveloped land in the city of Columbia Heights, Minnesota (the project site), see Figure 1. The project site is directly northeast of the Central Avenue intersection with 47th Avenue Northeast. Central Avenue borders the project to the west, 47th Avenue borders the project to the south, and Grand Avenue Northeast borders the project site to the east. The original site plan included 10 vacuum generators and 16 blowers, which would be the main sources of noise. 85 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 2 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Figure 1: Project Site and Receptors 86 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 3 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Existing Noise Environment The project site is located in an urban area where ambient sound levels are influenced by a variety of ongoing human activities. Existing noise sources in the vicinity generally include vehicular traffic on adjacent and nearby roadways (including Central Avenue Northeast/Trunk Highway 65), local transit operations, commercial activities, and occasional emergency vehicle sirens. Additional intermittent noise sources typical of urban environments, such as nearby construction activity, mechanical equipment, and general community activity, also contribute to the existing noise environment. As a result, background noise levels in the project area are characteristic of an urban setting where periods of elevated sound levels occur regularly and fluctuate throughout the day and night depending on traffic volumes and surrounding land uses Adjacent Noise Receptors Kimley-Horn identified 17 sensitive noise receptors near the project site. Receptors to the west are as close as 200 feet from the project site and include 3 apartment buildings, 1 hotel, and 1 restaurant patio. Receptors to the south are as close as 65 feet from the project site and include 3 apartment buildings and one single-family residence. Receptors to the east are as close as 40 feet from the project site and include 1 apartment building, 1 playground, and 1 multi-family residence. There is 1 receptor 100 feet north of the project site which is a restaurant patio. At receptor locations 12 – 15, there are 3 stories of apartment balconies facing the project at approximately 10, 20, and 30 feet above ground level. Characteristics of Noise Noise is generally defined as unwanted sound. It is emitted from many natural and man-made sources. Sound pressure levels are usually measured and expressed in decibels (dB). The decibel scale is logarithmic and expresses the ratio of the sound pressure unit being measured to a standard reference level. Most sounds occurring in the environment do not consist of a single frequency, but rather a broad band of differing frequencies. The intensities of each frequency add together to generate sound. Because the human ear does not respond to all frequencies equally, the method commonly used to quantify environmental noise consists of evaluating all of the frequencies of a sound according to a weighting system. It has been found that the A-weighted decibel (dBA) filter on a sound level meter, which includes circuits to differentially measure selected audible frequencies, best approximates the frequency response of the human ear. L10 is also a sound pressure metric that represents the sound pressure level, in dBA, exceeded ten percent of the time during a one-hour survey. Similarly, L50 represents the sound pressure level, in dBA, exceeded 50 percent of the time during a one-hour survey. The degree of disturbance from exposure to unwanted sound – noise – depends upon three factors: 1. The amount, nature, and duration of the intruding noise 2. The relationship between the intruding noise and the existing sound environment; and 3. The situation in which the disturbing noise is heard 87 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 4 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 In considering the first of these factors, it is important to note that individuals have varying sensitivity to noise. Loud noises bother some people more than other people, and some individuals become increasingly upset if an unwanted noise persists. The time patterns and durations of noise(s) also affect perception as to whether or not it is offensive. For example, noises that occur during nighttime (sleeping) hours are typically considered to be more offensive than the same noises in the daytime. With regard to the second factor, individuals tend to judge the annoyance of an unwanted noise in terms of its relationship to noise from other sources (background noise). A car horn blowing at night when background noise levels are low would generally be more objectionable than one blowing in the afternoon when background noise levels are typically higher. The response to noise stimulus is analogous to the response to turning on an interior light. During the daytime an illuminated bulb simply adds to the ambient light, but when eyes are conditioned to the dark of night, a suddenly illuminated bulb can be temporarily blinding. The third factor – situational noise – is related to the interference of noise with activities of individuals. In a 60 dBA environment such as is commonly found in a large business office, normal conversation would be possible, while sleep might be difficult. Loud noises may easily interrupt activities that require a quiet setting for greater mental concentration or rest; however, the same loud noises may not interrupt activities requiring less mental focus or tranquility. As shown in Figure 2, most individuals are exposed to fairly high noise levels from many sources on a regular basis. To perceive sounds of greatly varying pressure levels, human hearing has a non-linear sensitivity to sound pressure exposure. Doubling the sound pressure results in a three decibel change in the noise level; however, variations of three dBA or less are commonly considered “barely perceptible” to normal human hearing. A five decibel dBA change is more readily noticeable. A ten- fold increase in the sound pressure level correlates to a ten decibel [dBA] noise level increase; however, it is judged by most people as only sounding “twice as loud”. Over time, individuals tend to accept the noises that intrude into their lives on a regular basis. However, exposure to prolonged and/or extremely loud noise(s) can prevent use of exterior and interior spaces and has been theorized to pose health risks. 88 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 5 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Figure 2: Common Noise Levels 89 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 6 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Minnesota State Noise Standards The State of Minnesota regulates noise in Minnesota Rules, part 7030.0040. This rule establishes the noise standards in Table 1 based on Noise Area Classification (NAC). A NAC is based on the land use of the location where a person may hear noise. Noise from the project will be regulated according to the NAC of surrounding receptors. Table 1: Minnesota State Noise Standards Noise Area Classification Daytime Nighttime L10 L50 L10 L50 1: Residential housing, religious activities, camping and picnicking areas, health services, hotels, educational services 65 60 55 50 2: Retail, restaurants and bars, parks and playgrounds, business and government services, recreational activities, transit passenger terminals 70 65 70 65 3: Manufacturing, fairgrounds and amusement parks, agricultural and forestry activities 80 75 80 75 4: Undeveloped and unused land N/A N/A N/A N/A Local Regulations According to Section 4 (10)(d) of Ordinance 1711, for proposed car washes in the city of Columbia Heights, “A sound study is required to determine the overall impact upon the surrounding properties and ensure compliance with performance standards and [Minnesota Pollution Control Agency] MPCA sound requirements.” The MPCA requirements are consistent with the Minnesota State noise Standards listed above. This sound study is being prepared in accordance with this requirement. According to Chapter 30, Article II, Section 30-21 (a) of the Anoka County Code of Ordinances, “…between the hours of 10:00 p.m. and 7:00 a.m…No person shall engage in or permit heavy machinery activity involving the use of any kind of electric, diesel or gas-powered machine or other power.” The project will not operate outside of 7:00 a.m. to 10:00 p.m.. Noise Measurements Kimley-Horn used a Larson Davis SoundExpert Lxt Sound Level Meter (Serial No. 0005586) during a field visit to the West Saint Paul Crew Carwash on April 29, 2026. During this field visit, the noise analyst measured sound levels of typical equipment operations. The equipment at the West Saint Paul location is anticipated to have similar sound levels to equipment proposed for the project site. Three 1-minute measurements were conducted for a pair of operating vacuum generators in the parking lot at distances of 5, 10, and 20 feet from the nearest generator. Similarly, three 1-minute measurements were conducted for the blowers in the carwash building at distances of 5, 10, and 20 90 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 7 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 feet from the open garage door. These measurements were conducted while all blower units within the car wash building were operating. See Table 2 for the field measurement data. Table 2. Measured Operational Noise Levels (dB) Noise Source Distance (ft) 31 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 kHZ 2 kHZ 4 kHz 8 kHz Overall Noise Level (dBA) Blowers 5 48.1 64.2 74.4 83.5 91.3 93.1 93.8 88.1 77.6 98.4 10 46.0 63.9 71.6 80.5 89.2 91.3 91.8 85.8 75.0 96.4 20 41.3 60.3 68.6 75.8 85.0 86.9 87.6 81.5 70.5 92.0 Vacuum Generators 5 25.4 42.2 56.1 67.1 74.6 71.7 73.7 70.5 67.6 79.6 10 26.4 40.8 54.3 61.7 71.5 68.1 68.4 68.4 63.5 75.9 20 24.4 45.1 53.3 61.0 67.5 65.1 64.8 64.1 59.8 72.3 Noise Analysis Operational sound levels from the project were evaluated using SoundPLAN. This program computes predicted sound levels at noise-sensitive areas through a series of adjustments to reference sound levels. SoundPLAN also accounts for topography, groundcover type, and intervening structures. Sound levels generated from the on-site vacuum generators and the car wash blowers are anticipated to be the main sources of sound from the project. It should be noted that noise from surrounding roadways was not modeled in this analysis, although Central Avenue and other nearby roadways are anticipated to contribute to the ambient noise environment throughout the entire day. Vacuum Generators Vacuum generator equipment can generate steady, unvarying sound during daytime operation that may create issues when located near noise-sensitive areas. According to the original site layout, 10 vacuum generators were going to be located along the western boundary of the project site. Based on the field measurements discussed above, the modeled vacuum generators were calibrated to have an overall noise level one dBA louder than measurement data at 10 feet from the source. The modeled sound power of each vacuum generator is included in Table 3. Table 3. Modeled Sound Power of Vacuum Generator (dB) 31 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 kHZ 2 kHZ 4 kHz 8 kHz Overall Sound Power (dBA) 79.0 85.7 89.6 92.1 95.7 90.0 90.0 87.2 86.0 97.2 91 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 8 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Blower The blower system inside of the car wash can generate steady, unvarying sound during daytime operation that may create issues when located near noise-sensitive areas. In the current site layout, the tunnel exit near the blowers will be located on the southern façade of the building and the tunnel entrance, opposite the blowers, will be located on the northern façade. There are 16 blower units modeled in the standard configuration for Crew Carwash locations. Based on the field measurements discussed above, the modeled blowers were calibrated to have an overall noise level one dBA louder than measurement data at 20 feet from the tunnel exit. The modeled sound power of each blower is included in Table 4. Table 4. Modeled Sound Power of Individual Blower Unit 31 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 kHZ 2 kHZ 4 kHz 8 kHz Overall Sound Power (dBA) 92.0 98.3 98.5 100.6 102.9 102.3 101.5 95.8 87.0 107.2 Carwash Tunnel Layout The original carwash tunnel layout was modeled as three rooms with polyvinyl chloride-lined walls and concrete floors and ceilings. The tunnel entrance was modeled as 14 feet wide and 10 feet tall, a partition wall with a 14-foot-wide and 10-foot-tall opening was modeled 26 feet into the tunnel, a second partition wall with a 10-foot-wide and 8-foot-tall opening was modeled approximately 108 feet into the tunnel, the tunnel exit was also modeled as 10 feet wide and 8 feet tall. Results The project would only operate during daytime hours (7 a.mm to 10 p.m.) so results were compared to the MPCA daytime L50 thresholds. The model predicts that 13 of the 17 receptors would not comply with MPCA noise standards without mitigation. See Table 2 for anticipated unmitigated noise levels at noise sensitive receptors. See for a map of unmitigated noise levels surrounding the project site under normal operations. Table 5. Modeled Receptor Noise Levels with no Mitigation Receptor Modeled Noise Level (dBA) In compliance? ID Land Use NAC Height Above Ground (ft) Daytime L50 Threshold (dBA) 1 Restaurant 2 5 65 61.0 Yes 2 Restaurant 2 5 65 61.7 Yes 3 Multi-family residence 1 5 60 65.3 No 92 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 9 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Receptor Modeled Noise Level (dBA) In compliance? ID Land Use NAC Height Above Ground (ft) Daytime L50 Threshold (dBA) 4 Multi-family residence 1 5 60 65.5 No 5 Hotel 1 5 60 64.5 No 6 Hotel 1 5 60 64.3 No 7 Multi-family residence 1 5 60 71.0 No 8 Multi-family residence 1 5 60 79.8 No 9 Multi-family residence 1 5 60 80.0 No 10 Multi-family residence 1 5 60 77.7 No 11 Single-family residence 1 5 60 71.5 No 12 Multi-family residence 1 10 60 67.8 No 12 Multi-family residence 1 20 60 68.0 No 12 Multi-family residence 1 30 60 68.0 No 13 Multi-family residence 1 10 60 60.4 No 13 Multi-family residence 1 20 60 61.8 No 13 Multi-family residence 1 30 60 61.8 No 14 Multi-family residence 1 10 60 67.9 No 14 Multi-family residence 1 20 60 67.7 No 14 Multi-family residence 1 30 60 67.7 No 15 Multi-family residence 1 10 60 67.4 No 15 Multi-family residence 1 20 60 67.2 No 15 Multi-family residence 1 30 60 67.2 No 16 Playground 2 5 65 64.9 Yes 17 Multi-family residence 1 5 60 58.3 Yes 93 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 10 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Figure 3: Modeled Operational Noise Contours without Mitigation 94 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 11 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Recommended Mitigation To bring noise levels into compliance with MPCA noise standards, Kimley-Horn proposes the following noise mitigation measures: Vacuums To reduce noise levels, it is recommended that the vacuum units are reconfigured so that suction is generated at a single location within the carwash tunnel rather than outside, at the vacuum unit. Further, a vacuum nozzle with lower operational noise levels is recommended for this location. Based on coordination with Crew Carwash and the vacuum manufacturer, Kimley-Horn assumed a noise level of 68.1 dBA at 30 feet from the quieter vacuum unit. The modeled sound power at each vacuum unit was calibrated to reflect this quieter noise level but maintain the same spectral spread across frequencies as the field measurements, see Table 6. Table 6. Modeled Sound Power of Quieter Vacuum Nozzle 31 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 kHZ 2 kHZ 4 kHz 8 kHz Overall Sound Power (dBA) 77.6 84.2 88.1 90.6 94.2 88.1 88.5 85.7 84.5 95.7 Kimley-Horn also recommends that the number of vacuum units be reduced from 10 to 8 to further reduce noise levels at nearby receptors. Additionally, it is recommended the remaining 8 units are moved to the northern extent of the proposed parking lot and that a 20-foot-long, 8-foot-high brick noise wall be installed adjacent to the southernmost vacuum unit. Carwash Tunnel Layout It is recommended that the 16 blower units and other applicable carwash equipment are moved within the tunnel to allow for a 30-foot-long sound deadening room adjacent to the tunnel exit. Kimley-Horn recommends installing two (2) 8-foot tall, 10-foot-wide aluminum roller doors at each end of the carwash tunnel. For noise from the blower units to be adequately shielded, it is recommended that one of these aluminum roller doors always remain closed while the blower units are operational. In addition to adding a sound-deadening room, Kimley-Horn recommends lining all walls of the carwash tunnel, including the ceiling, with AcoustiBlok 5-inch Quietfiber, see Appendix A for product absorption data. To ensure this sound absorbing treatment does not deteriorate and lose efficacy, Acoustiblok recommends installing their waterproofing treatment to the Quietfiber if it will be frequently exposed to wet conditions. The original model was updated to reflect the recommended changes to the vacuum equipment, site layout, and interior of the carwash tunnel. The updated model predicts that all receptors would comply 95 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 12 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 with MPCA noise standards. See Table 7 for anticipated mitigated noise levels at noise sensitive receptors. See Figure 4 for a map of mitigated noise levels surrounding the project site under normal operations. Table 7. Modeled Receptor Noise Levels with Mitigation Receptor Modeled Noise Level (dBA) In compliance? ID Land Use NAC Height Above Ground (ft) Daytime L50 Threshold (dBA) 1 Restaurant 2 5 65 56.3 Yes 2 Restaurant 2 5 65 51.9 Yes 3 Multi-family residence 1 5 60 57.5 Yes 4 Multi-family residence 1 5 60 58.9 Yes 5 Hotel 1 5 60 59.3 Yes 6 Hotel 1 5 60 59.9 Yes 7 Multi-family residence 1 5 60 55.1 Yes 8 Multi-family residence 1 5 60 56.0 Yes 9 Multi-family residence 1 5 60 55.3 Yes 10 Multi-family residence 1 5 60 47.8 Yes 11 Single-family residence 1 5 60 42.9 Yes 12 Multi-family residence 1 10 60 43.9 Yes 12 Multi-family residence 1 20 60 47.4 Yes 12 Multi-family residence 1 30 60 48.3 Yes 13 Multi-family residence 1 10 60 44.7 Yes 13 Multi-family residence 1 20 60 48.1 Yes 13 Multi-family residence 1 30 60 49.2 Yes 14 Multi-family residence 1 10 60 57.7 Yes 14 Multi-family residence 1 20 60 57.7 Yes 14 Multi-family residence 1 30 60 57.7 Yes 15 Multi-family residence 1 10 60 57.8 Yes 15 Multi-family residence 1 20 60 57.8 Yes 15 Multi-family residence 1 30 60 57.8 Yes 16 Playground 2 5 65 56.0 Yes 17 Multi-family residence 1 5 60 51.6 Yes 96 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 13 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Figure 4. Modeled Operational Noise Levels with Mitigation 97 Item 5. Crew Carwash Columbia Heights, MN - Sound Study May 2026 - Page 14 kimley-horn.com 767 North Eustis Street, Suite 100, Saint Paul, MN 55114 651 645 4197 Conclusions The project site is located on undeveloped land adjacent to noise-sensitive land uses including residences, a hotel, restaurant patios, and a playground. The city of Columbia Heights enforces MPCA noise standards; therefore, project noise levels must comply with the daytime L50 noise thresholds. 13 of the 17 modeled noise-sensitive receptors adjacent to the project site would exceed the daytime L50 noise thresholds without noise abatement. Kimley-Horn has recommended alterations to vacuum equipment, installation of a noise wall, and addition of a sound deadening room to the carwash tunnel. Following coordination with Crew Carwash, Kimley-Horn has implemented these mitigation measures into the current site plans. These recommendations resulted in modeled noise levels that comply with MPCA noise standards. Kimley-Horn encourages Crew Carwash to continue consultation with noise control engineers to ensure the final project design remains compliant with MPCA noise standards. 98 Item 5. Appendix A. Acoustiblok Quietfiber Datasheet 99 Item 5. Acoustiblok Quietfiber 2”, 3” & 5” – NRC Data 2 Inch Thick Quietfiber 3 Inch Thick Quietfiber NRC 1.0 NRC 1.10 5 Inch Thick Quietfiber NRC 1.10 Frequency Absorption Coefficient 40 Hz 0.00 50 Hz 0.00 63 Hz 0.00 80 Hz 0.09 100 Hz 0.29 125 Hz 0.51 160 Hz 0.60 200 Hz 0.82 250 Hz 0.85 315 Hz 0.96 500 Hz 1.02 1000 Hz 1.04 2000 Hz 1.00 4000 Hz 1.05 6300 Hz 1.18 8000 Hz 1.24 10000 Hz 1.37 12500 Hz 1.62 Frequency Absorption Coefficient 40 Hz 0.02 50 Hz 0.07 63 Hz 0.13 80 Hz 0.08 100 Hz 0.61 125 Hz 0.91 160 Hz 1.03 200 Hz 1.17 250 Hz 1.09 315 Hz 1.19 500 Hz 1.20 1000 Hz 1.09 2000 Hz 1.07 4000 Hz 1.05 6300 Hz 1.10 8000 Hz 1.14 10000 Hz 1.21 12500 Hz 1.42 Frequency Absorption Coefficient 40 Hz 0.00 50 Hz 0.04 63 Hz 0.25 80 Hz 0.60 100 Hz 0.97 125 Hz 1.23 160 Hz 1.14 200 Hz 1.24 250 Hz 1.09 315 Hz 1.12 500 Hz 1.15 1000 Hz 1.10 2000 Hz 1.09 4000 Hz 1.07 6300 Hz 1.11 8000 Hz 1.13 10000 Hz 1.25 12500 Hz 1.41 100 Item 5. City of Columbia Heights | Community Development Department 3989 Central Avenue NE, Columbia Heights, MN 55421 ▪ Ph: 763-706-3670 ▪ Fax: 763-706-3671 www.columbiaheightsmn.gov NOTICE OF PUBLIC HEARING Date of Hearing: Tuesday, July 7, 2026 Subject: Public Hearing Notice – Conditional Use Permit Subject Property: (anticipated address) 4707 Central Ave NE (PID: 25-30-24-32-0182) Dear Resident/Affected Property Owner: The City of Columbia Heights has received an application for a Conditional Use Permit to establish a Car Wash at 4707 Central Ave. Section 9.104 (H) of the Zoning Ordinance requires the Planning Commission to hold a public hearing and provide a recommendation that the City Council approve or deny the application. You are receiving this notice because the property that you own (Affected Property), and/or reside in, is located within 350 feet of the Project Site (4707 Central Ave NE). The Planning Commission of the City of Columbia Heights will hold a Public Hearing on this matter on Tuesday, July 7, 2026 at 6:00 p.m. at City Hall, 3989 Central Avenue NE. A full copy of the application is on file at City Hall and is available for review upon request. You are welcomed and encouraged to participate in the Public Hearing for this matter by attending the July 7, 2026 Planning Commission meeting. If you cannot attend the meeting, but would like to provide input, you can submit correspondence via email to ubrandt@columbiaheightsmn.gov or by mail at: City of Columbia Heights Attn: Community Development 3989 Central Avenue NE Columbia Heights, MN 55421 You can also participate in the meeting online by logging into the TEAMS meeting with the information below: Website: columbiaheightsmn.gov/joinameeting ID: 252 220 349 450 48 Passcode: uH7gL3dY If you have any questions about this proposal, please do not hesitate to contact the City of Columbia Heights Community Development Division at (763) 706-3670. Sincerely, Ursula Brandt City Planner, City of Columbia Heights ** Landowners (Commercial and Residential): If you do not reside on the Affected Property, located 350 feet 101 Item 5. from the Subject Property, it is your responsibility to share this notice with your tenants. This notice should be posted in a public place on your property or mailed directly to the tenants residing or leasing space on the Affected Property. -SUBJECT PROPERTY LOCATIONS- 102 Item 5. Name Address 1 Address 2 4730-4750 CENTRAL AVE NE LLC 1415 19TH AVE NE MINNEAPOLIS, MN 55418 4760 LLC 3611 ADAIR AVE N CRYSTAL, MN 55422 950 TYLER LLC 11159 HOLLAND CIR EDEN PRAIRIE, MN 55347 AGHA, HANA 1070 GRANDVIEW CT NE UNIT 108 COLUMBIA HEIGHTS, MN 55421 ANDERSON, LAYNE ELIZABETH 1070 GRANDVIEW CT NE UNIT 304 COLUMBIA HEIGHTS, MN 55421 ANOKA COUNTY COMMUNITY ACTION PROGRAM 1201 89TH AVE NE STE 3500 BLAINE, MN 55434 ARMOLD, LINDA M 4813 GRAND AVE NE COLUMBIA HEIGHTS, MN 55421 BIERNAT, PAUL L 1070 GRANDVIEW CT NE UNIT 306 COLUMBIA HEIGHTS, MN 55421 CITIES INVESTMENT GROUP LLC 2136 FORD PKWY UNIT 8064 SAINT PAUL, MN 55116 COLUMBIA HEIGHTS LEASED HOUSING ASSO 2905 NORTHWEST BLVD STE 150 PLYMOUTH, MN 55441 COLUMBIA HGHTS LEASED HSG ASSOC III LLLP 2905 NW BLVD STE 150 MINNEAPOLIS, MN 55441 DEMETRIOU, MARTHA A 11159 HOLLAND CIR EDEN PRAIRIE, MN 55347 DEV LLC 4720 CENTRAL AVE NE HILLTOP, MN 55421 DIRIE, WALI 4636 POLK ST NE COLUMBIA HEIGHTS, MN 55421 DORN, BARBARA J 2 MAIN ST NICOLLET, MN 56074 FINCKINC LLC 17059 LIVORNO DR PACIFIC PALISADES, CA 90272 FORSTER, CURTIS & VIRGINIA 2459 BIRCH ST WHITE BEAR LK, MN 55110 FRANKLIN, ALYSIA 1070 GRANDVIEW CT NE UNIT 308 COLUMBIA HEIGHTS, MN 55421 GAMBLE SHANNON LA-NETTE 1070 GRANDVIEW CT NE UNIT 307 COLUMBIA HEIGHTS, MN 55421 GANI, SAGAL MOHAMMED 4648 POLK ST NE COLUMBIA HEIGHTS, MN 55421 GLENDE JOLENE 4825 GRAND AVE NE COLUMBIA HEIGHTS, MN 55421 GRAND CENTRAL LOFTS MASTER ASSOCIATION 7100 MADISON AVE W GOLDEN VALLEY, MN 55427 GRAND CENTRAL LOFTS TOWNHOMES ASSOCIATION 7100 NORTHLAND CIR N STE 300 BROOKLYN PARK, MN 55428 HASMUKH LLC 195 CHANTICLEER LN ALAMO, CA 94507 HASSAN, MUSTAFA 4641 TYLER ST NE COLUMBIA HEIGHTS, MN 55421 HOLTON, ANDREA 4801 GRAND AVE NE COLUMBIA HEIGHTS, MN 55421 HOOKS THOMAS A 1070 GRANDVIEW CT NE 204 COLUMBIA HEIGHTS, MN 55421 IBRAHIM, IFRAH A 4647 TYLER ST NE COLUMBIA HEIGHTS, MN 55421 KANG REBECCA 1070 GRANDVIEW CT NE UNIT 403 COLUMBIA HEIGHTS, MN 55421 KIMBERLY A NYBO INSURANCE AGENCY INC 4634 CENTRAL AVE NE HILLTOP, MN 55421 KMF GROUP LLC 2147 UNIVERSITY AVE W UNIT 203 SAINT PAUL, MN 55114 KUDUK, ELAINE 4807 GRAND AVE NE COLUMBIA HEIGHTS, MN 55421 KURAK, THOMAS 15001 SUNFISH LAKE BLVD RAMSEY, MN 55303 KURTH, JUDY A 1070 GRANDVIEW CRT UNIT 106 COLUMBIA HEIGHTS, MN 55421 LOX PROPERTIES LLC 1395 COMMERCE DR MENDOTA HEIGHTS, MN 55120 MAC D LLC 1008 NEWHALL DR FARIBAULT, MN 55021 103 Item 5. MANTHEY, CAROL JEAN 1070 GRANDVIEW CT NE UNIT 103 COLUMBIA HEIGHTS, MN 55421 MARCATOMA, GENARO M 2312 CENTRAL AVE NE MINNEAPOLIS, MN 55418 MN STATE OF IN TRUST 2100 3RD AVE ANOKA, MN 55303 MONTY REALTY LLC 160 83RD AVE STE 104 FRIDLEY, MN 55432 MORGAN II LLC 195 CHANTICLEAR LN ALAMO, CA 94507 NGO, SON THANH 4819 GRAND AVE NE COLUMBIA HEIGHTS, MN 55421 OBRADOVEC, DINA 1070 GRAND VIEW CT APT 201 COLUMBIA HEIGHTS, MN 55421 PETERMAN, KATHY 1070 GRANDVIEW CT NE UNIT 107 COLUMBIA HEIGHTS, MN 55421 PLATH, BRIAN 1070 GRANDVIEW CT NE UNIT 202 COLUMBIA HEIGHTS, MN 55421 RUBIN, RENEE 1070 GRANDVIEW CT NE UNIT 105 COLUMBIA HEIGHTS, MN 55421 SAMIR & KAWTHAR PROPERTIES 461 W MARYLAND AVE STE 203 ST PAUL, MN 55117 SCHMIDT, SANDRA I 1070 GRANDVIEW CT NE UNIT 400 COLUMBIA HEIGHTS, MN 55421 SEKIZOVIC, MUAMER 12849 LEYTE ST NE BLAINE, MN 55449 STAGG, THOMAS W 1070 GRANDVIEW CT NE UNIT 102 COLUMBIA HEIGHTS, MN 55421 TABOR, DANIEL THOMAS 1070 GRANDVIEW CT NE UNIT 314 COLUMBIA HEIGHTS, MN 55421 THOEMKE STEPHEN E 1070 GRANDVIEW CT NE UNIT 310 COLUMBIA HEIGHTS, MN 55421 THOENNES, MICHAEL J 10875 GREER CIR SW HOWARD LAKE, MN 55349 TOTEM FOODS INC PO BOX 23210 RICHFIELD, MN 55423 TW PROPERTY LLC 6949 EDINGTON CIR SHAKOPEE, MN 55379 WIECHMAN, SARA ANN 1070 GRANDVIEW CT NE UNIT 312 COLUMBIA HEIGHTS, MN 55421 WILSON, DOUG 1070 GRANDVIEW CT NE 100 COLUMBIA HEIGHTS, MN 55421 YOUNT JR., ROBERT JULIUS 1070 GRANDVIEW CT NE UNIT 203 COLUMBIA HEIGHTS, MN 55421 104 Item 5. 105 Item 5. PLANNING COMMISSION AGENDA SECTION OTHER BUSINESS MEETING DATE JULY 7, 2026 ITEM: Review Acquisition of 4217 Central Ave NE DEPARTMENT: Community Development BY/DATE: Ursula Brandt, 10-7-2025 Presenting Item: Ursula Brandt, City Planner CORE CITY STRATEGIES: (please indicate areas that apply by adding an “X” in front of the selected text below) X Community that Grows with Purpose and Equity _High Quality Public Spaces _Safe, Accessible and Built for Everyone X Engaged, Effective and Forward-Thinking _Resilient and Prosperous Economy _Inclusive and Connected Community LOCATION: 4217 Central Ave NE REQUEST: Review the acquisition of 4217 Central Ave NE, and determine if it conforms to the City’s Comprehensive Plan PREPARED BY: Ursula Brandt, City Planner INTRODUCTION: Pursuant to State Statute, Section 462.356, Subdivision 2, the Planning and Zoning Commission (the “Planning Commission”) in and for the City is required to review and determine whether the proposed acquisition of real property by the City’s Economic Development Authority (EDA), conforms to the Comprehensive Plan of the City. Therefore, the EDA has requested that the Planning Commission review the acquisition of 4217 Central Ave NE, Columbia Heights, MN 55421 (the “Subject Property”) to determine if its acquisition conforms to the Comprehensive Plan of the City. COMPREHENSIVE PLAN: The EDA has a long-standing practice of acquiring blighted single-family homes to facilitate scattered site redevelopment, and the proposed acquisition of the Subject Property responds to several goals and policies adopted in the Comprehensive Plan. Specifically, in Chapter 3: Land Use, and Chapter 4: Housing. Below are the specific goals and policies from the Comprehensive Plan that directly and indirectly correlate to the conformity of the proposed acquisition. Land Use and Redevelopment (chapter 3) Goal: Provide mechanisms for successful redevelopment of vacant lands and targeted areas within the community. 106 Item 6. Page 2 1. Encourage infill development that demonstrates compatibility with existing neighborhood characteristics in terms of quality, design, building height, placement, scale, and architectural quality. Goal: Strengthen the identity and image of the community as a desirable place to live, work, and play. 1. Enhance the physical appearance of the community through clean-up initiatives, redevelopment opportunities, and housing renovation programs. STAFF RECOMMENDATION Staff Recommends the adoption of Resolution 2026-PZ01, as it meets the goals of the Comprehensive Plan and supports Core City Strategies. RECOMMENDED MOTION(S): MOTION: Move to waive the reading of Resolution 2026-PZ01, there being ample copies available to the public. MOTION: Move to adopt Resolution 2026-PZ01, a resolution finding that the acquisition of certain land for redevelopment purposes by the Columbia Heights Economic Development Authority is consistent with the City of Columbia Heights’ Comprehensive Plan. ATTACHMENT(S):  Resolution 2026-PZ01  Location Map 107 Item 6. RESOLUTION NO. 2026-PZ01 A RESOLUTION FINDING THAT THE ACQUISITION OF CERTAIN LAND FOR REDEVELOPMENT PURPOSES BY THE COLUMBIA HEIGHTS ECONOMIC DEVELOPMENT AUTHORITY IS CONSISTENT WITH THE CITY OF COLUMBIA HEIGHTS’ COMPREHENSIVE PLAN. The Columbia Heights Economic Development Authority (the “Authority”) proposes to purchase certain property (the “Property”) located at Central Ave NE, (PID 36-30-24-23-0042) in the City of Columbia Heights (the “City”) and described on the attached Exhibit A, for the purposes of eventual redevelopment; and Minnesota Statutes, Section 462.356, subd. 2 requires the City’s Planning Commission to review the proposed acquisition or disposal of publicly owned real property within the City prior to its acquisition or disposal, to determine whether in the opinion of the Planning Commission, such acquisition or disposal is consistent with the comprehensive municipal plan; and NOW, THEREFORE BE IT RESOLVED, the Planning Commission has reviewed the proposed acquisition of the Property and has determined that the Authority’s purpose is to redevelop the Property, and that the proposed acquisition is therefore consistent with the City’s comprehensive plan. BE IT FURTHER RESOLVED that this resolution be communicated to the Board of Commissioners of the Authority. ORDER OF THE PLANNING COMMISSION Passed this 7th day of July, 2026 Offered by: Seconded by: Roll Call: Chairperson Attest: Secretary 108 Item 6. EXHIBIT A Description of Property RESERVOIR HILLS, COLUMBIA HEIGHTS, ANOKA COUNTY, MINNESOTA LOT 29, BLK 3, RESERVOIR HILLS 109 Item 6. Location Map of 4217 Central Ave 110 Item 6.