Loading...
HomeMy WebLinkAbout2017-2770I 1 Inspection Proposal J.N. Johnson Fire & Safety nNA Division of 05 Company Address 4200 West 76th Street Created Date 1/10/2017 Minneapolis, MN 55435 -5108 Quote Number 00003447 Phone (952) 835 -4600 Project Code 161191 -14852 Fax (952) 835 -4153 Account Information Account Name Columbia Heights Public Works Service Location Ship To Name Columbia Heights Public Works Bill To Name Columbia Heights Fire Dept Ship To 637 38th Ave NE Bill To 825 41st Ave NE Columbia Heights, MN Columbia Heights, MN Direct Dial (763) 706 -8152 Phone (763) 706 -8150 Email ggorman @columbiaheightsmn.gov Scope Of Work Opportunity Name 2016,11 FA EL AI - Columbia Heights Public Works Description LVC will provide the following life safety system inspections according to the MN State Fire Alarm and Suppression Contract # 56031, Release # F- 547(5). Site Contact: - Gary Gorman Fire Chief 1763-706-8150 ( ggorman @columbiaheightsmn.gov - Eric Hanson: Facility Supervisor 1763-706-3725 1 ehanson2 @columbiaheightsmn.gov Scope Of Work: Annual Fire Alarm System Inspection Annual Emergency Lighting Inspection Fire Alarm System: - 1 FCI 7100 Series Panel - 5 Manual pull stations - 13 Smoke detectors - 3 Duct detectors - 29 Heat detectors - All A/V appliances - All batteries Emergency Lighting System: 15 .Dual Lite LXURWEI Lights - 5 Dual Lite LZ20N1 Lights 5 ELPE AP25Q Lights Project Specifics: LVC Fire Alarm Division will supply up to 5 hours of labor. Annual Emergency =Light Inspection - 90 minute load test will be performed. Inspection will be completed during normal business hours Monday - Friday. - A thorough system review will be performed using individual point testing procedures. Facility personnel will provide uninterrupted access to equipment needing inspection. Alarm control panels will be checked for line voltages, battery voltage under normal and alarm activation conditions, ground fault tolerance, and supervision of all data loops. - All alarm notifications will be verified to ensure proper response Inspection Proposal J.N. Johnson Ei Fare & Safety ANA Division of - Reports of inspection will be provided electronically within 30 days of inspection completion. - Deficient findings will be identified and corrective action proposals will be provided for approval. Excluded: - Sales Tax, permits, fees - Overtime labor - Service labor and / or equipment - Personnel lift equipment Quote Line Items Labor - Fire Alarm Emergency Lighting Inspection Investment Subtotal $867.00 Discount 0.00% Total Price $867.00 Signatures Jim Oelhafen Approved By: Service Sales Representative 952 -278 -1075 Direct 952 - 292 -1017 Cell Printed Name: Walt Fehst joelhafen @lvcinc.com Title: City Manager Date: January 13, 2017