MAINTENANCE AGREEMENT FOR ENVIRONMENTAL SYSTEMS
Company
Horwitz Inc
4401 Quebec Avenue North
New Hope, MN 55428
Ph: (763)- 533 -1900
Bill To Identity
Fax: (763)-235-9810
City of Columbia Heights
590 40th Avenue N.E.
Columbia Heights, MN 55421
Attn: Eric Hanson
Agreement: Page 1 of 21
Proposal Date: 12/19/2016
Proposal Number: AP -16 -067
Agreement Number;
Agreement Location
City of Columbia Heights
590 40th Avenue N.E.
Columbia Heights, MN 55421
Attn: Eric Hanson
Horwitz Inc will provide the services described in the maintenance program indicated below.
MAINTENANCE PROGRAM: PM
Schedules Included:
21 Equipment Schedule
(Only Items Checked Apply)
0 Air Filter Service
❑ Building Automation ❑ Customized Service
Agreement coverage will commence on 1/1/2017
❑ Water Treatment
❑ Special Conditions Service
The Agreement price is $ 58,308.00 per year, payable in advanced installments of $ 14,577.00 per
Quarter beginning on the effective date of 1/1/2017
This Agreement is the property of Horwitz Inc and is provided for Customer's use only. Horwitz Inc guarantees the price
stated in this Agreement for thirty (30) days from proposal date above. This Agreement is for an initial term of 1 Year and
shall renew for successive one year terms unless either party gives written notice to the other of intention not to renew thirty
(30) days prior to any anniversary date. Upon execution as provided below, this Agreement, including the following pages
attached hereto (collectively, the "Agreement "), shall become a binding and enforceable agreement against both parties
hereto. Customer, by execution of this Agreement, acknowledges that it has reviewed and un tands the attached terms
and conditions and has the authority to enter into this Agreement.
Company �
_J L
gignature �a ers Consu an
Accepted for Company By:
Jdc
name live i
12/19/2016 (763) -533 -1900 (763) -235 -9810
hone ax
Gary L. Peterson Walter R. Fehst
Name n ype
Mayor City Manager
a�
/>biaturrz°9�:
�OriT Lt/ITZw.i�
M�c�+i�rti QOi-s TnvGY�ON
Equipment Schedule
Agreement: Page 2 of 21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
CITY HALL
Rooftop Units
1
RT0001- CounChamb
Carrier
48HJE007 -541
Field Verify
Field
Roof
Verify
1
RT0002- Breakroom
Carrier
48HJE007 -541
4801G20195
Field
Roof
Verify
1
RT0003 -Admin
Carrier
48HJE007 -541
4801G20193
Field
Roof
Verify
1
RT0004- CommDevel
Bryant
Field Verify
Field Verify
Field
Roof
Verify
1
RT0005- Finance
Bryant
Field Verify
Field Verify
Field
Roof
Verify
1
RT0006- Packaged
Carrier
48HJE007
Field Verify
Field
Roof
Verify
1
RT0007- Packaged
Carrier
48HJE007
Field Verify
Field
Roof
Verify
Condensing Units
1
CondensingUnit001
Goodman
CK18 -16
9404022676
Field
Roof
Verify
1
CondensingUnit002
Comfortmaker
Field Verify
Field Verify
Field
Roof
Verify
1
CondensingUnit003
Comfort Aire
AVMH -24SC1
Field Verify
Field
Roof
Verify
Blowers
1
Blower001
Goodman
Field Verify
Field Verify
Field
Conf Room
Verify
1
Blower002
Larkin
Field Verify
Field Verify
Field
Comp Room
Verify
Ceiling
Furnaces- Forced Air
1
Fumace001
Comfortmaker
Field Verify
Field Verify
Field
Election Room
Verify
Make -Up Air Units
1
MUA001
AppliedAir
AppliedAir
Field Verify
Field
Fire Bay
Verify
1
MUA002
Environmental
Field Verify
Field Verify
Field
Former
Air
Verify
Boiler Systems
1
Boiler001
RBI
Field Verify
Field Verify
Field
Boiler Room
Verify
1
Boiler002
RBI
Field Verify
Field verify
Field
Boiler Room
Verify
/brv...rrz
Equipment Schedule
Agreement: Page 3 of 21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Pumps
1 Pump001
Field Verify
1510BF725
C15326202G21
Field Boiler Room
1 Pump002
Field Verify
1510BF725
C15326201G21
Verify
Field Boiler Room
1 Pump003
Field Verify
2X5257875BF
C15326301G21
Verify
60HP Boiler Room
1 Pump004
Field Verify
2X5254875BF
C153263D2G21
60HP Boiler Room
1 PUmp005
Field Verify
Field Verify
Field Verify
Field Boiler Room
Verify
Cabinet Heaters
1 CabinetHeater001
Field Verify
Field Verify
Field Verify
Field Stairwell
1 CabinetHeater002
Field Verify
Field Verify
Field Verify
Verify
Field Stairwell
1 CabinetHeater003
Field Verify
Field Verify
Field Verify
Verify
Field Stairwell
1 CabinetHeater004
Field Verify
Field Verify
Field Verify
Verify
Field Hose Room
Verify
Unit Heaters
1 UnitHeater001- HotWater
Modine
Modine
Field Verify
Field Fire Bay
1 UnitHeater002- HotWater
Modine
Modine
Field Verify
Verify
Field Fire Bay
1 UnitHeater003- HotWater
Modine
Modine
Field Verify
Verify
Field Fire Bay
1 UnitHeater004- HotWater
Modine
Modine
Field Verify
Verify
Field Fire Bay
1 UnitHeaterU05- HotWater
Modine
Modine
Field Verify
Verify
Field Fire Bay
1 UnitHeater006- HotWater
Modine
Modine
Field Verify
Verify
Field Fire Bay
1 UnitHeater007- HotWater
Modine
Modine
Field Verify
Verify
Field Fire Bay
1 UnitHeater008- HotWater
Modine
Modine
Field Verify
Verify
Field Garage
1 UnitHeater009
Field Verify
Field Verify
Field Verify
Verify
Field Entry Way
1 UnitHeater010
Field Verify
Field Verify
Field Verify
Verify
Field Entry Way
Verify
�orzr�r z
Equipment Schedule
Agreement: Page 4 of 21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Exhaust Fans
1
ExhaustFan001
Field Verify
4YC67A
Field Verify
Field
Restroom
Verify
1
ExhaustFan002
Field Verify
4YC66
Field Verify
Field
Restroom
Verify
1
ExhaustFan003
Field Verify
PB12C
Field Verify
Field
Hose Tower
Verify
1
ExhaustFan004
Field Verify
Field Verify
Field Verify
Field
Coun. Chmb.
Verify
1
ExhaustFan005
Field Verify
Field Verify
Field Verify
Field
Fire Bay
Verify
1
ExhaustFan006
Field Verify
Field Verify
Field Verify
Field
Fire Bay
Verify
1
ExhaustFan007
Field Verify
Field Verify
Field Verify
Field
Fire Bay
Verify
1
ExhaustFan008
Field Verify
Field Verify
Field Verify
Field
IS Office Area
Verify
1
ExhaustFan009
Field Verify
Field Verify
Field Verify
Field
IS Office Area
Verify
Motors
1
Motor001
B &G
LQE56B17D116K
E12K180035
Field
Stairwell
Verify
1
Motor002
Field Verify
L1408T
F1201093889
Field
Boiler Room
Verify
1
Motor003
Field Verify
L1408T
F1203193239
Field
Boiler Room
Verify
Zone Dampers
1
ZoneDamper001
Honeywell
Field Verify
Field Verify
Field
LL Ceiling
Verify
1
ZoneDamper002
Honeywell
Field Verify
Field Verify
Field
LL Ceiling
Verify
Misc Equipment
1
Water Heater001
Bradford White
M15036FBN
3F16843100
Field
Boiler Room
Verify
1
DomCircPump001
B &G
Field Verify
Field Verify
Field
Boiler Room
Verify
1
Humidifier001
Field Verify
Field Verify
Field Verify
Field
Stairwell/F
Verify
HOI?t/JITZ
Mw6wn'wvn� Oor�a YN�icrww
Equipment Schedule
Agreement: Page 5 of .21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
PARK, PUMP, $ LIFT
STATIONS
1
Gas Fired Unit Heaters
1
GasUnitHeater001
Reznor
FT75
AWK71T9N31039 Field
Pump H #2
1
GasUnitHeater002
Chromalox
LUH100
Verify
Field Verify Field
Pump H #3
1
GasUnitHeater003
Lennox
G24M314
Verify
6397BO7348 Field
Gauvitti Park
Verify
Furnaces
1
Fumace001
Arco Aire
GU1150
Field Verify Field
Huset Park
1
Fumace002
Goodman
GMP1505
Verify
9606814584 Field
Keyes Park
1
Fumace003
Goodman
GMP1505
Verify
Field Verify Field
Mathaire Park
1
Fumace004
Goodman
GMP1505
Verify
9412106097 Field
McKenna Park
1
Fumace005
Comfortmaker
CN1100
Verify
GNI10OA06DIN Field
Ostrander Park
1
Fumace006
AO Smith
Field Verify
Verify
Field Verify Field
Prestemon Park
Verify
Water Heaters
1
WaterHeater001
AO Smith
Field Verify
Field Verify Field
Huset Park
1
WaterHeater002
AO Smith
Field Verify
Verify
Field verify Field
Keyes Park
1
WaterHeater003
AO Smith
Field Verify
Verify
Field Verify Field
Mathaire Park
1
WaterHeater004
AO Smith
Field Verify
Verify
Field Verify Field
McKenna Park
1
WaterHeater005
AO Smith
Field Verify
Verify
Field Verify Field
Ostrander Park
1
WaterHeater006
AO Smith
Field Verify
Verify
Field Verify Field
Prestemon Park
Verify
Radiation Baseboard
Heaters
1
RadiationHeater001
Field Verify
Field Verify
Field Verify Field
Sul. Lift. St.
Verify
Norrc�p-rz
Mace�w�wowi. O owarw uo row
Equipment Schedule
Agreement: Page 6 of 21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
PUBLIC WORKS
Rooftop Units
1
RTU001
Bryant
581BPV102224ALH
5005650561
Field
Roof
Q
Verify
Condensing Units
1
CU001
Bryant
550AN048000AFAA
2705E07384
Field
Roof
Verify
1
CU002
Bryant
550AN048000AFAA
Field Verify
Field
Roof
Verify
1
CU003
Bryant
550AN048000AFAA
Field Verify
Field
Roof
Verify
Make -Up Air Units
1
MUA001
Titan
TAM115NGHRH
10398
Field
Upper Level
Verify
1
MUA002
Titan
TAM115NGHRH
10397
Field
Upper Level
Verify
1
MUA003
Titan
TAM115NGHLH
10396
Field
Upper Level
Verify
1
MUA004
Titan
TA127NGHLH
10395
Field
Basement
Verify
Pulse Furnaces
1
PulseFumace001
Bryant
350AAV048100
4805AO1960
Field
Janitors Closet
Verify
1
PulseFumace002
Bryant
350AAB060100
4905A01470
Field
Janitors Closet
Verify
1
PulseFurnace003
Bryant
350AAV060100
Field Verify
Field
Boiler Room
Verify
Ventilators
1
HRV001
Renew Aire
HE2xRTH
10051096
Field
Roof
Verify
Exhaust Fans
1
ExhaustFan001
Field Verify
Field Verify
Field verify
Field
Lower Level
Verify
1
ExhaustFan002
Field Verify
Field Verify
Field Verify
Field
Lower Level
Verify
1
ExhaustFan003
Field Verify
Field Verify
Field verify
Field
Lower Level
Verify
1
ExhaustFan004
Field Verify
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan005
Field Verify
Field Verify
Field verify
Field
Roof
Verify
/Ibe..arz�+
/70/?L�JIT.Z
Mac Hnw�as�� Qnwsri+'unr�bw
Equipment Schedule
Agreement: Page 7 of 21
JY6ov,...r=
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
1
ExhaustFan006
Field Verify
Field Verify
Field Verify
Field Roof
1
ExhaustFan007
Field Verify
Field Verify
Field Verify
Verify
Field Roof
1
ExhaustFan008
Field Verify
Field Verify
Field Verify
Verify
Field Basement
1
ExhaustFan009
Field Verify
Field Verify
Field Verify
Verify
Field Basement
1
ExhaustFan010
Field Verify
Field Verify
Field Verify
Verify
Field Basement
1
ExhaustFan011
Field Verify
Field Verify
Field. Verify
Verify
Field Basement
1
ExhaustFan012
Field Verify
Field Verify
Field Verify
Verify
Field Basement
1
ExhaustFan013
Field Verify
Field Verify
Field Verify
Verify
Field Basement
1
ExhaustFan014
Field Verify
Field Verify
Field Verify
Verify
Field Basement
Unit Heaters
Verify
1
UnitHeater001
Reznor
UDAP250
BEF79Y3N1986OX
Field Upper Level
1
UnitHeater002
Reznor
UDAP250
BEF79Y3N19360X
Verify
Field Upper Level
1
UnitHeater003
Dunham Bush
H250C
Field Verify
Verify
Field Upper Level
1
UnitHeater004
Dunham Bush
H250C
Field Verify
Verify
Field Upper Level
1
UnifHeater005
Dunham Bush
H250C
Field Verify
Verify
Field Upper Level
1
UnitHeater006
Trane
GBND015ADA1000
A89FO7201
Verify
Field Upper Level
1
UnitHeater007
Trane
2
GBND015ABA1000
A89FO7201
Verify
Field Basement
1
UnitHeater008
Trane
2
GBND015ABA100E
A89FO7202
Verify
Field Basement
1
UnitHeater009
Trane
GBND015ADA1000
A89FO7199
Verify
Field Basement
1
UnitHeater010
Trane
E
GBND015ADA1000
A89FO7206
Verify
Field Basement
1
UnitHeater011
Field Verify
E
Field Verify
Field Verify
Verify
Field Basement
1
UnitHeater012
Field Verify
Field Verify
Field Verify
Verify
Field Basement
1
UnitHeater013
Field Verify
Field Verify
Field Verify
Verify
Field Basement
1
UnitHeater -14
Field Verify
Field Verify
Field Verify
Verify
Field 2nd Floor
Verify
JY6ov,...r=
/70/7LtgTZ
Mao «w «�aw� On«srnuvr�o«
Equipment Schedule
Agreement: Page 8 of 21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Water Heaters
1
WaterHeater001
Lochinvar
EGO080
HA14422032
Field
2nd Floor
Verify
1
WaterHeater002
Field Verify
Field Verify
Field Verify
Field
2nd Floor
Verify
Hot Water Circ Pumps
1
Pump001
Field Verify
Field Verify
Field verify
Field
2nd Floor
Verify
1
Pump002
Rundfos
UP2699BF
Field Verify
Field
2nd Floor
Verify
1
Pump003
Field Verify
Field Verify
Field Verify
Field
2nd Floor
Verify
1
Pump004
B &G
1.89 +75
Field Verify
Field
2nd Floor
Verify
Motorized Dampers
1
Damper001
Belimo
Field Verify
Field Verify
Field
Lower Level
Verify
1
Damper002
Belimo
Field Verify
Field Verify
Field
Lower Level
Verify
1
Damper003
Belimo
Field Verify
field Verify
Field
Lower Level
Verify
LIBRARY
Chiller Systems
1
Chiller001
Trane
RAUJC404B
C15M07609
Outside North
1 - Compressor
40 Tons
1
Chiller002
Trane
RAUJC204BC
C15MO7610
Outside South
1 - Compressor
20 Tons
1
Pump003
Baldor
EM3615T
36M524S26
5 HP
Mech Room
1
Pump004
Baldor
EM3615T
36M524S26
5 HP
Mech Room
Boiler Systems
1
Boiler001
Aerco
AM 500 B
14090937
15 Blr HP
Mech Room
1
Boiler002
Aerco
AM 500 B
14230036
15 Blr HP
Mech Room
1
Pump001
Baldor
CEM3546
35AO12M49
1 HP
Mech Room
1
Pump002
Baldor
CEM3546
35AO12M49
1 HP
Mech Room
I�f! `TZi
MOQHN+�cn� 6rn�.crnr.�r�o�a
Equipment Schedule
Agreement: Page 9 of 21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#!
RATING
LOCATION
Air Handler(s)
1
AH0001
Trane
CSAA01OUAL
K15M95784
Upper Wall
1 - Supply Fan Motor
1 HP
1
AH0002
Trane
CSAA050UAL
K15M95794
Mech Room
1 - Supply Fan Motor
1 HP
Package Unit(s)
1
Mini Split System
Liebert
MMDA18A -P
Y15LB10430
1.5 Tons
Server Room
*** Split System * **
1 - Compressor
1.5 Tons
Special Pump(s)
1
Pump for SnoMelt001
Taco
EM3157T -G
35z069M496
2 HP
Mech Room
1 - Variable Speed Drive
2 HP
Misc. Equipment
1
Boiler for SnoMelt
Aerco
AM 50 B
14090935
Mech Room
1
Dom Water Heater
AO Smith
EJC 10 200
15493007790
Mech Room
1
Tank for SnoMelt
Taco
CS94 -125
403107
Mech Room
1
VFD for SnoMelt
Yaskawa
LP1 S CKT
Field Verify
Mech Room
3
VFDs
Yaskawa
Field Verify
Field Verify
Mech Room
16
Fan - Powered VAV Boxes
Field Verify
Field Verify
Various
TOP VALU 1
Rooftop Units
1
RT0001
Trane
YHC048E3RHA05H
737102130L
4 Ton
Roof
1
RTUO02
Trane
YHC036ERHA05H
737100042L
3 Ton
Roof
1
RT0003
Trane
YHC036E3RHA05H
737100696L
3 Ton
Roof
2
1
RT0004
Trane
YHC048E3RHA05H
738101759L
4 Ton
Roof
1
RT0005
Trane
YHC048ERHA05H
738101763L
4 Ton
Roof
1
RTUO06
Trane
YHC048E3RHA05H
738102404L
4 Ton
Roof
1
RT0007
Trane
YHC036E3RHA05H
737100048L
3 Ton
Roof
f7�RWT�
��!?IlJIT.Z.i
Equipment Schedule
Agreement: Page 10 of 21
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Condensing Units
1
C0001
Heatcraft
LDT1200M6CF
707303721
Field
Roof
Verify
1
C0002
Heatcraft
LDT1200M6CF
T0710320
Field
Roof
Verify
Power Roof Ventilators
1
Ventilator001
Cook
90ACEL90C15DL
29759628880000
Field
Roof
Verify
1
Ventilator002
Cook
10OC15DH
29759628880000
Field
Roof
Verify
1
Ventilator003
Cook
90C15DM
24759628880000
Field
Roof
Verify
Unit Heaters
1
UnitHeater001
Modine
Field Verify
Field Verify
Field
M.Basement
Verify
1
UnitHeater002
Modine
Field Verify
Field Verify
Field
M.Basement
Verify
1
UnitHeater003
Modine
Field Verify
Field Verify
Field
M.Basement
Verify
1
UnitHeater004
Modine
Field Verify
Field Verify
Field
M.Basement
Verify
Water Heaters
1
WaterHeater001
Rheem
Field Verify
Field Verify
Field
Verify
TOP VALU II
Rooftop Units
1
RT0001
Trane
YHC048E3RHA05H
738102392L
4 Ton
Roof
1
RT0002
Trane
YHC036E3RHA05H
738102392L
3 Ton
Roof
1
RT0003
Trane
YHC048E3RHA05H
738102386L
4 Ton
Roof
1
RT0004
Trane
YHC036E3RHA05H
737100708L
3 Ton
Roof
1
RT0005
Trane
YHC036E3RHA05H
738102398L
3 Ton
Roof
1
RT0006
Trane
YHC036E3RHA05H
737101609L
3 Ton
Roof
Condensing Units
1
C0001
Heatcraft
LDT1200MGCF
T07103718
Field
Roof
Verify
1
C0002
Heatcraft
LDT1200MGCF
707303719
Field
Roof
Verify
Agreement: Page 11 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Power Roof Ventilators
1
Ventilator001
Cook
90C15DM
29759628890000
Field
Roof
Verify
1
Ventilator002
Cook
100C2B33
29759628890000
Field
Roof
Verify
1
Ventilator003
Cook
9OC15DL
29759628890000
Field
Roof
Verify
1
Ventilator004
Cook
100ACE100C2B33
297S9628890000
Field
Roof
Verify
Unit Heaters
1
UnitHeater001
Modine
Field Verify
Field Verify
Field
Sprinkler Room
Verify
1
UnitHeater002
Modine
Field Verify
Field Verify
Field
Storage Room
Verify
1
UnitHeater003
Modine
Field Verify
Field Verify
Field
Entry
Verify
1
UnitHeater004
Modine
Field Verify
Field Verify
Field
Above Cooler
Verify
1
UnitHeater005
Modine
Field Verify
Field Verify
Field
Storage Room
Verify
1
UnitHeater006
Modine
Field Verify
Field Verify
Field
Storage Room
Verify
Water Heaters
1
WaterHeater001
Rheem
Field Verify
Field Verify
Field
Cooler
Verify
HEIGHTS LIQUOR
Condensing Units
1
C0001
Century
CRK5052DHSC
188834662
Field
Beer Cooler
Verify
1
C0002
Field Verify
Field Verify
Field verify
3 Ton
Roof
Forced Air Furnaces
1
Fumace001
Snyder General
GUA10OA016AIN
Field Verify
Field
Basement
Verify
1
Fumace002
Snyder General
GUA10OA016AIN
Field Verify
Field
Basement
Verify
Water Heaters
1
WaterHeater001
Field Verify
Field Verify
Field Verify
Field
Basement
Verify
Agreement: Page 12 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
MURZYN HALL
Boiler Systems
1
Boiler001
Cutler Hammer
M -350
PS25768
Field
Mech Room
Verify
1
Boiler002
Cutler Hammer
M350
PS25773
Field
SE Mech Room
Verify
1
Boiler003
Cutler Hammer
M350
PS25777
Field
SE Mech Room
Verify
1
131rCircPump001
Grundfos
UPS2699FC
PN52722512P1
Field
SE Mech Room
Verify
1
13lrCircPump002
Grundfos
UPS2699FC
PN52722512131
Field
SE Mech Room
Verify
1
BlrCircPump003
Grundfos
UPS2699FC
PN52722512P1
Field
SE Mech Room
Verify
Hot Water Circ Pumps
1
Pump001
Grundfos
UPS4016OF
PN96402784
Field
SE Mech Room
Verify
1
Pump002
Grundfos
UPS4016OF
PN96402784
Field
SE Mech Room
Verify
1
Pump003
Grundfos
UPS4016OF
PN96402798
Field
SE Mech Room
Verify
1
Pump004
Grundfos
UPS4016OF
PN96402798
Field
SE Mech Room
Verify
Condensing Units
1
C0001
Trane
RAUCC30EBY030B
C07FO6705
Field
Ground Level
DF
Verify
1
C0002
Trane
RAUCC20EB10300
C08L10662
Field
Ground Level
D
Verify
1
C0003
Trane
TTA120C300GC
84715R6AD
Field
Ground Level
Verify
1
C0004
Trane
2TTA306OA3000AA
8444LWA4F
Field
Ground Level
Verify
Air Handling Units
1
AH0001
Trane
CCD825ENBE
K86A89619
Field
NW Mech Room
Verify
1
AH0002
Trane
MCCB012UAOAOUA
K08K24847A
Field
Attic
Verify
1
AH0003
Trane
MCCB008UAOAOUB
K081-24852A
Field
Attic
Verify
1
AH0004
Trane
BCHCO54E1 COA21
T081-67670
Field
Attic
A5F
Verify
Agreement. Page 13 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Return Air Fans
1
Fan001
Trane
NOMHP
Field Verify
Field
Verify
1
Fan002
Trane
NOMHP
Field Verify
Field
Verify
1
Fan003
Trane
NOMHP
Field Verify
Field
Verify
Cabinet Heaters
1
CabinetHeater001
Sterling
Field Verify
Field Verify
Field
Verify
1
CabinetHeater002
Sterling
Field Verify
Field Verify
Field
Verify
1
CabinetHeater003
Sterling
Field Verify
Field Verify
Field
Verify
1
CabinetHeater004
Sterling
Field Verify
Field Verify
Field
Verify
1
CabinetHeater005
Sterling
Field Verify
Field Verify
Field
Verify
Split Systems
1
MiniSplitAC001
Goodman
GMA024
Field Verify
Field
Office
Verify
1
MiniSplitAC002
Goodman
GMA024
Field Verify
Field
Office
Verify
Misc. Equipment
1
WaterHeater001
AO Smith
FSG75230
GKO066278230
Field
SE Mech Room
Verify
1
Humidifier
Carnes
HBDGCU020
276641001
Field
NW Mech Room
Verify
PUBLIC SAFETY
Air Handling Units
1
AH0001
McQuay
Field Verify
Field Verify
Field
Mech Room
Verify
1
AH0002
McQuay
Field Verify
Field Verify
Field
Mech Room
Verify
1
AH0003
McQuay
Field Verify
Field Verify
Field
Mech Room
Verify
Direct Fired MUAs
1
MUA001
Titan
Field Verify
Field Verify
Field
Mezzanine
Verify
Agreement: Page 14 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Fan - Powered VAV Boxes
36
VAVs
Titus
Field Verify
Field Verify
Field
Ceiling
Verify
Geo Thermal Heat Pumps
1
HeatPump001
Trane
Field Verify
Field Verify
Field
Mech Room
Verify
1
HeatPump002
Trane
Field Verify
Field Verify
Field
Mech Room
Verify
1
HeatPump003
Trane
Field Verify
Field Verify
Field
Mech Room
Verify
Heat Pumps
1
HeatPump004
Trane
Field Verify
Field Verify
Field
Ceiling
Verify
1
HeatPump005
Trane
Field Verify
Field Verify
Field
Ceiling
Verify
1
HeatPump006
Trane
Field Verify
Field Verify
Field
Ceiling
Verify
1
HeatPump007
Trane
Field Verify
Field Verify
Field
Ceiling
Verify
1
HeatPump008
Trane
Field Verify
Field Verify
Field
Ceiling
Verify
Circulating Pumps
1
CircPump001
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump002
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump003
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump004
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump005
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump006
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump007
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump008
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump009
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump010
B &G
Field Verify
Field Verify
Field
Building
Verify
Agreement: Page 15 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
1
CircPump011
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump012
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump013
B &G
Field Verify
Field Verify
Field
Building
Verify
1
CircPump014
B &G
Field Verify
Field Verify
Field
Building
Verify
Well Pumps
1
WellPump001
B &G
Field Verify
Field Verify
Field
Building
Verify
1
WellPump002
B &G
Field Verify
Field Verify
Field
Building
Verify
1
WelIPump003
B &G
Field Verify
Field Verify
Field
Building
Verify
1
WellPump004
B &G
Field Verify
Field Verify
Field
Building
Verify
1
WellPump005
B &G
Field Verify
Field Verify
Field
Building
Verify
Infrared Heaters
1
Heater001
Reverberay
Field Verify
Field Verify
Field
Truck Bay
Verify
1
Heater002
Reverberay
Field Verify
Field Verify
Field
Truck Bay
Verify
1
Heater003
Reverberay
Field Verify
Field Verify
Field
Truck Bay
Verify
Gas Unit Heaters
1
Heater004
Modine
GMA024
Field Verify
Field
Building
Verify
1
Heater005
Modine
GMA024
Field Verify
Field
Building
Verify
1
Heater006
Modine
GMA024
Field Verify
Field
Building
Verify
1
Heater007
Modine
GMA024
Field Verify
Field
Building
Verify
1
Heater008
Modine
GMA024
Field Verify
Field
Building
Verify
1
Heater009
Modine
GMA024
Field Verify
Field
Building
Verify
1
Heater010
Modine
GMA024
Field Verify
Field
Building
Verify
1
Heater011
Modine
GMA024
Field Verify
Field
Building
Verify
Agreement: Page 16 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Cabinet & Electric Heaters
1
Heater012
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater013
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater014
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater015
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater016
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater017
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater018
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater019
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater02O
Field Verify
Field Verify
Field Verify
Field
Building
Verify
1
Heater021
Field Verify
Field Verify
Field Verify
Field
Building
Verify
Fan Coil Units
1
FC0001
Trane
Field Verify
Field Verify
Field
Lower Level
Verify
Garage
Split Systems
1
MiniSplitAC001
Carrier
Field Verify
Field Verify
Field
Lower Level
Verify
Garage
Energy Recovery
Ventilators
1
Ventilator001
RenewAire
Field Verify
Field Verify
Field
Mech Room
Verify
Water Heaters
1
InstWaterHeater001
Navien
N199
Field Verify
Field
Mezzanine
Verify
1
lnstWaterHeater002
Navien
N199
Field Verify
Field
Mezzanine
Verify
1
InstWaterHeater003
Navien
N199
Field Verify
Field
Mezzanine
Verify
1
WaterHeater004
AO Smith
Field Verify
Field Verify
50 Gallon
Mezzanine
Agreement; Page 17 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
Exhaust Fans
1
ExhaustFan001
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan002
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan003
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan004
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan005
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhuastFan006
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan007
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan008
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan009
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan010
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan011
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan012
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan013
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan014
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan015
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan016
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan017
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan018
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan019
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan02O
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan21
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan22
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
1
ExhaustFan23
Greenheck
Field Verify
Field Verify
Field
Roof
Verify
Agreement; Page 18 of 21
Equipment Schedule
QTY
EQUIPMENT
MANUFACTURER
MODEL
SERIAL#
RATING
LOCATION
1
ExhaustFan24
Greenheck
Field Verify
Field Verify
Field
Verify
Roof
�or�t�rrz
oo.......�T��
Agreement. Page 19 of 21
This Preventative Maintenance Agreement includes quarterly visits with filter changes. Annual belt
changes and condenser coil cleaning are also included.
VFDs will be inspected and cleaned semi - annually. Fault history and set points will be checked and
reported to customer.
This Agreement is based on the ASHRAE standard 180 -2008.
NEW Library: the filters on the 16 Fan - Powered VAV Boxes will be changed twice annually.
Mwarswwwwa Coww'rnwT.ow
PM Program Agreement. Page 20 of 21
This agreement is designed to provide the Customer with an ongoing maintenance program. This
agreement will be initiated, scheduled, administered, monitored and updated by the Service Provider.
The service activities will be directed and scheduled, on a regular basis, by our comprehensive
equipment maintenance scheduling system based on manufacturers' recommendations, equipment
location, application, type, run time, and Service Provider's own experience. The Customer is informed
of the agreement's progress and results on a continuing basis via a detailed Service Report presented
after each service call for Customer's review, approval signature and record.
SERVICE PROVIDER WILL PROVIDE THE FOLLOWING PROFESSIONAL MAINTENANCE SERVICES FOR
THE BUILDING ENVIRONMENTAL MECHANICAL SYSTEM(S) COMPRISED OF THE EQUIPMENT LISTED ON
SCHEDULE 1 (INVENTORY OF EQUIPMENT):
TEST AND INSPECT: On -Site labor, travel labor and travel and living expenses required to visually
INSPECT and TEST equipment to determine its operating condition and efficiency. Typical activities
include:
• TESTING for excessive vibration; motor winding resistance; refrigerant charge; fan RPM;
refrigerant oil (acid); water condition; flue gas analysis; safety controls, combustion and draft;
crankcase heaters, control system(s), etc.
• INSPECTING for worn, failed or doubtful parts; mountings, drive couplings; oil level; rotation
soot;
flame composition and shape; pilot and igniter; steam, water, oil and /or refrigerant leaks, etc.
PREVENTIVE MAINTENANCE: On -Site labor, travel labor and travel and living expenses required to
clean, align, calibrate, tighten, adjust, lubricate and paint equipment. These activities are intended to
extend equipment life and assure proper operating condition and efficiency. Typical activities include:
• CLEANING coil surfaces; fan impellers and blades; electrical contacts; burner orifices; passac
and nozzles; pilot and igniter; cooling tower baffles, basin, sump and Float; chiller, condenser
and boiler tubes, etc.
• ALIGNING belt drives; drive couplings; coil fins, etc.
• CALIBRATING safety controls; temperature and pressure controls, etc.
• TIGHTENING electrical connections; mounting bolts; pipe clamps; refrigerant piping fittings;
damper sections, etc.
• ADJUSTING belt tension; refrigerant charge; super heat; fan RPM; water chemical feed and
feed rate; burner fuel /air ratios; gas pressure; set point of controls and limits; compressor
cylinder unloaders; damper close -off; sump floats, etc.
• LUBRICATING motors; fan and damper bearings; valve stems; damper linkages; fan vane
linkages, etc.
PAINTING, for corrosion control, as directed by our scheduling system and on an as- needed
basis.
I�R4II'TZ3..
M�aMnw�.� oe..yr.iwr�o..
PM Terms and Conditions Agreement; Page 21 of 21
1. Customer shall permit Service Provider free and timely access to areas and equipment, and allow Service Provider to start and stop the
equipment as necessary to perform required services. All planned work under this Agreement will be performed during the Service Provider's
normal working hours.
2. In case of any failure to perform its obligations under this Agreement, Service Provider's liability is limited to repair or replacement at Its option
and such repair or replacement shall be Customer's sole remedy. This warranty is conditioned upon proper operation and maintenance by Customer
and shall not apply if the failure Is caused or contributed to by accident, alteration, abuse or misuse, and shall not extend beyond the term of this
Agreement.
3. The annual Agreement price is conditioned upon the system(s) covered being in a maintainable condition. If the initial Inspection or initial
seasonal start-up indicates repairs are required, a firm quotation will be submitted for Customer's approval. Should Customer not authorize the
repairs, Service Provider may either remove the unacceptable system(s), component(s) or part(s) from its scope of responsibility and adjust the
annual agreement price accordingly or cancel this Agreement.
4. The annual Agreement price is subject to adjustment on each commencement anniversary to reflect increases in labor, material and other costs.
5. Customer shall be responsible for all taxes applicable to the services and /or materials hereunder.
6. Customer will promptly pay invoices within thirty (30) days of receipt. Should a payment become thirty (30) days or more delinquent, Service
Provider may stop all work under this Agreement without notice and /or cancel this Agreement, and the entire Agreement amount shall become due
and payable immediately upon demand.
7. Any alteration to, or deviation from, this Agreement Involving extra work, cost of materials or labor will become an extra charge (fixed price
amount to be negotiated or on a time- and - material basis at Service Provider's rates then In effect) over the sum stated in this Agreement.
B. Service Provider will not be required to move, replace or alter any part of the building structure in the performance of this Agreement.
9. Customer shall permit only Service Provider's personnel or agent to perform the work included in the scope of this Agreement. Should anyone
other than Service Provider's personnel perform such work, Service Provider may, at its option, cancel this Agreement or eliminate the involved item
of equipment from inclusion in this Agreement.
10. In the event Service Provider must commence legal action in order to recover any amount payable under this Agreement, Customer shall pay
Service Provider all court costs and attorneys' fees incurred by Service Provider.
11. Any legal action against the Service Provider relating to this Agreement, or the breach thereof, shall be commenced within one (1) year from
the date of the work.
12. Service Provider shall not be liable for any delay, loss, damage or detention caused by unavailability of machinery, equipment or materials, delay
of carriers, strikes, including those by Service Provider's employees, lockouts, civil or military authority, priority regulations, insurrection or riot,
action of the elements, forces of nature, or by any cause beyond its control.
13. To the fullest extent permitted by law, Customer shall indemnify and hold harmless Service Provider, Its agents and employees from and against
all claims, damages, losses and expenses, including but not limited to attorneys' fees, arising out of or resulting from the performance of work
hereunder, provided that such claim, damage, loss or expense is caused in whole or in part by an active or passive act or omission of Customer,
anyone directly or indirectly employed by Customer, or anyone for whose acts Customer may be liable, regardless of whether It is caused in part
by the negligence of Service Provider. Further and nothwithstanding the preceding sentence, service provider shall be held harmless and shall not
be liable to customer for any claims, liabilities, damages, losses and expenses related to mold or the creation of mold at customers location(s) and
shall have no obligation to treat, identify or remove such mold.
14. Customer shall make available to Service Provider's personnel all pertinent Material Safety Data Sheets (MSDS) pursuant to OSHA'S Hazard
Communication Standard Regulations.
15. Service Provider expressly disclaims any and all responsibility and liability for the indoor air quality of the customer's facility, including without
limitation injury or Illness to occupants of the facility or third parties, arising out of or in connection with the Service Provider's work under this
agreement.
16. Service Provider's obligation under this proposal and any subsequent contract does not include the identification, abatement or removal of
asbestos or any other toxic or hazardous substances, hazardous wastes or hazardous materials. In the event such substances, wastes and
materials are encountered, Service Provider's sole obligation will be to notify the Owner of their existence. Service Provider shall have the right
thereafter to suspend its work until such substances, wastes or materials and the resultant hazards are removed. The time for completion of the
work shall be extended to the extent caused by the suspension and the contract price equitably adjusted.
17. UNDER NO CIRCUMSTANCES, WHETHER ARISING IN CONTRACT, TORT (INCLUDING NEGLIGENCE), EQUITY OR OTHERWISE, WILL SERVICE
PROVIDER BE RESPONSIBLE FOR LOSS OF USE, LOSS OF PROFIT, INCREASED OPERATING OR MAINTENANCE EXPENSES, CLAIMS OF CUSTOMER'S
TENNANTS OR CLIENTS, OR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES.
18.This agreement does not include repairs to the system(s), the provisions or installationof components or parts, or service calls requested by the
customer. These services will be charged for at Service Provider's rates then in effect.
/lLiireurrz'�
SCHEDULE
[01
AIR HANDLING UNITS
Inspection/Maintenance Task Frequency
Check air filter and housing integrity. At Filter Change
Check control system and devices for evidence of improper operation. Repair, adjust or Semi - annually
replace components to ensure proper operation.
Check P -trap. Prime as needed to ensure proper operation. Semi - annually
Check fan belt tension. Check for belt wear and proper alignment. Semi - annually b
Check variable frequency drive for proper operation. Correct as needed. Semi - annually
Check for proper operation of cooling or heating coil. Clean, restore or replace as Semi - annually
required.
Check control box for dirt, debris and/or loose terminations. Clean and tighten as needed. Annually
Check motor contactor for pitting or other signs of damage. Repair or replace as needed. Annually
Check fan blades. Clean, repair or replace as needed to ensure proper operation.
Annually
Check refrigerant system pressures and/or temperatures. If outside of recommended
Annually
levels, find cause, repair and adjust refrigerant to achieve optimal operating levels.
Check for fouling, corrosion or degradation. Clean or repair as needed.
Annually
Check drive alignment, wear, seating and operation. Repair or replace as needed.
Annually
Check integrity of all panels on equipment. Replace fasteners as needed to ensure
Annually
proper integrity and fit /finish of equipment.
Lubricate field serviceable bearings.
Annually
Check drain pan, drain line and coil for biological growth. Clean as needed.
Annually
Check coil fins for evidence of build -up or fouling. Restore if possible. Replace coil
Annually
if necessary to return to proper functioning.
Inspect dampers, linkage, positioning and operation. Lubricate dampers.
Annually
Inspect for evidence of moisture carryover beyond the drain pan from the cooling coils.
Annually
Make corrections or repairs as necessary.
Visually inspect areas of moisture accumulation for biological growth. If present,
Annually
clean or disinfect as needed.
Check condensate pump. Clean or replace as needed. Annually
Visually inspect exposed ductwork and external piping for insulation and vapor Annually
barrier for integrity. Correct as needed.
Visually inspect internally lined ductwork until the first turn or up to 20 feet into the Annually
supply plenum from the air handler for integrity, and if soiled or degraded, correct.
a Filters changed quarterly with high efficiency pleated type.
6 Replace belt annually.
BOILER POWER BURNERS
Inspection/Maintenance Task Frequency
Shut down and lock out tag out boiler system power and fuel systems.
Semi - annually
Gain access to internal components of burner for inspection,
Semi- annually
Visually inspect burner flame retainer and head assemblies for cracking or warping.
Semi- annually
Visually inspect combustion chamber and fire brick for damage or wear.
Semi - annually
Disassemble burner as needed for service.
Semi - annually
Remove pilot assembly and all corresponding components for inspection and cleaning.
Semi - annually
Inspect all hand and automatic gas valves for signs of wear or leaking.
Semi - annually
Inspect all oil circulation and pressure pumps.
Semi- annually
Clean and oil combustion air motors, and clean combustion air fan wheel.
Semi- annually
Reassemble complete boiler and burner assemblies.
Semi - annually
Set all necessary pilot clearances and electrode specifications upon reinstallation.
Semi- annually
Inspect and test burner blowers, electrodes, changeover switches, and pressure- trols.
Semi - annually
Inspect boiler room combustion air intake for proper operation and interlock with burner.
Semi - annually
Start system and check for operating conditions, pressures, temperatures, flow rates,
Semi - annually
flame quality and efficiency. Perform automatic shut -off valve timing tests.
After boiler has reached operating temperature and pressure perform combustion
Semi - annually
efficiency test.
Check all fuel and air pressures and make necessary adjustments for all fuels associated Semi - annually
with burner.
Perform final operating operating/safety controls test including blow down, low water Semi - annually
cut -off, high limits, high pressure controls.
Perform pressure relief test. Semi - annually
Inspect boiler trim, access ports, vents, air separators, and immediate piping for signs Semi - annually
of leakage.
BOILERS
Ins pection/Maintenance Task Frequency
Perform chemical testing of system water. Treat as needed to ensure proper water Semi- annually
chemistry.
Check fuel pump for proper operation. Repair or replace as needed to ensure proper Semi- annually
operation.
Inspect blow -down or drain valve. Clear all debris to ensure proper operation. Repair or Semi - annually
replace if needed.
Check system traps, pumps and controls. Clean or replace as needed to ensure proper Semi - annually
operation.
Check control box for dirt, debris and/or loose terminations. Clean and tighten as needed. Annually
Check motor contactor for pitting or other signs of damage. Repair or replace as needed. Annually
Check for fouling, corrosion or degradation. Clean or repair as needed. Annually
Check for evidence of build -up or fouling on heat exchange surfaces (tubes). Clean to Annually
ensure proper operation.
Check for proper damper operation. Repair, replace or adjust as needed. Annually
Check combustion chamber, burner and flue for deterioration, moisture problems, Annually
condensation, and combustion products. Clean, test and adjust combustion process
for proper operation.
Open all water side access ports and clean and flush any corrosion or sludge from boiler
Annually
Open all low water cut offs for inspection
Annually °
Open all water level controls for inspection
Annually
Open all control /trim piping for inspection
Annually
Reassemble boiler replacing gaskets as necessary
Annually
After start up, check boiler trim, access ports, vents, air separators and immediate
Annually
Piping for signs of leakage
° by insurance company or state inspector where applicable
CONDENSING UNITS
Inspection/Maintenance Task
Frequency
Check control system and devices for evidence of improper operation. Repair, adjust,
Semi - annually
or replace components to ensure proper operation.
Check fan belt tension. Check for belt wear and proper alignment.
Semi - annually b
Adjust expansion valve superheat where applicable
Semi - annually
Check condenser coil sub cooling
Semi - annually
Verify and record evaporator temperature drop
Semi- annually
Check filter -drier for restrictions and sight glass for moisture where applicable
Semi - annually
Check control box for dirt, debris and/or loose termination. Clean and tighten as needed.
Annually
Check motor contactor for pitting or other signs of damage. Repair or replace as needed.
Annually
Check fan blades for balance and particulate buildup. Clean, repair or replace as needed
Annually
to ensure proper operation.
Check refrigerant system pressures or temperatures. If outside of recommended levels, Annually
find cause, repair and adjust refrigerant to achieve optimal operating levels.
Check for fouling, corrosion, leaks or degradation. Clean or repair as needed. Annually
Check drive alignment, wear, seating and operation. Repair or replace as needed. Annually
For direct coupled fan/motor assemblies, check bearings and lubricate field serviceable
or replace motor if needed.
Inspect air - cooled condenser surfaces. Repair or clean as needed. Annually
Check low ambient head pressure control sequence for proper operation. Repair or Annually
replace components or modify software /algorithm to ensure proper operation.
Check refrigerant oil levels for refrigerant systems with oil pressure/level controls. Annually
Repair, replace or adjust as needed to ensure proper operation.
Replace belt annually.
DEHUMIDIFCATION AND HUMIDIFCATION DEVICES
Ins pection/Maintenance Task Frequency
Measure relative humidity and repair, clean, or adjust system as necessary to ensure Semi - annually
intended operation.
Check system traps, pumps and controls. Clean or replace as needed to ensure Semi - annually
proper operation.
Check for fouling, corrosion or degradation. Clean or repair as needed. Annually
Check for evidence of build -up or fouling on heat exchange surfaces. Clean as needed Annually
to ensure proper operation.
Check for excessive scale or debris on evaporative condenser surfaces. Clean as needed Annually
Inspect, clean or replace generator tanks or evaporative pads where applicable Annually
Perform operating functions including drain test, test of control limits and safeties Annually
Check strainers. Clean as needed. Annually
Visually inspect areas of moisture accumulation for biological growth. If present, Annually
clean or disinfect as needed.
FAN COILS, HOT WATER UNIT HEATERS
Inspection/Maintenance Task Frequency
Check air filter and housing integrity At Filter Change'
Check system traps, pumps and controls. Clean or replace as needed to ensure proper Semi - annually
operation.
Check control system and devices for evidence of improper operation. Repair, adjust or Semi - annually
replace components to ensure proper operation.
Check P -trap. Prime as needed to ensure proper operation. Semi - annually
Check fan belt tension. Check for belt wear and proper alignment. Semi - annually b
Check for proper operation of cooling or heating coil. Clean, restore or replace as Semi - annually
required.
Check control box for dirt, debris and/or loose terminations. Clean and tighten as Annually
needed.
Check fan blades. Clean, repair or replace as needed to ensure proper operation.
Annually
Check refrigerant system pressures or temperatures. If outside of recommended levels,
Annually
find cause, repair and adjust refrigerant to achieve optimal operating levels.
Check for fouling, corrosion or degradation. Clean or repair as needed.
Annually
Check drive alignment, wear, seating and operation. Repair and replace as needed.
Annually
Check integrity of all panels on equipment. Replace fasteners as needed to ensure
Annually
proper integrity and fit /finish of equipment.
Lubricate field serviceable bearings.
Annually
Check drain pan, drain line and coil for biological growth. Clean as needed.
Annually
Check coil fns. Restore if possible. Replace coil if necessary to return to proper
Annually
functioning.
Inspect for evidence of moisture carryover beyond the drain pan from cooling coils. Annually
Make corrections or repairs as necessary.
Check for proper damper operation. Repair, replace or adjust as needed. Annually
Visually inspect areas of moisture accumulation for biological growth. If present, Annually
clean or disinfect as needed.
Check condensate pump. Clean or replace. Annually
a Filters changed quarterly with high efficiency pleated type.
b Replace belt annually.
FURNACES, RESIDENTIAL
Inspection/Maintenance Task
Frequency
Check air filter and housing integrity.
At Filter Change'
Check control system and devices for evidence of improper operation. Repair, adjust or
Semi - annually
replace components to ensure proper operation.
Check fan belt tension. Check for belt wear and proper alignment.
Semi - annually b
Check control box for dirt, debris and/or loose terminations. Clean and tighten as needed.
Annually
Check fan blades. Clean, repair or replace as needed to ensure proper operation.
Annually
Check drive alignment, wear, seating and operation. Repair and replace as needed.
Annually
Check integrity of all panels on equipment. Replace fasteners as needed to ensure
Annually
proper integrity and fit/finish of equipment.
Lubricate field serviceable bearings.
Annually
Clean heat exchanger as applicable
Annually
Clean and adjust pilot assembly or main ignition source
Annually
Adjust pressure regulator
Annually
Check and adjust all safety controls
Annually
Check fan operating control and complete furnace cycle
Annually
Check for proper damper operation. Repair, replace or adjust as needed.
Annually
Check combustion chamber, burner and flue for deterioration, moisture problems,
Annually
condensation, and combustion products, including carbon monoxide analysis. Clean,
test and adjust combustion for proper and efficient operation.
Check heat exchanger. Clean as necessary to ensure proper operation and to remove
Annually
scale and sediment. Check for possibility of leaks.
a Filters changed quarterly with high efficiency pleated type.
b Replace belt annually.
Inspection/Maintenance Task FURNACES, UNIT HEATERS Frequency
Check air filter and housing integrity. At Filter Change
Check fuel pump for proper operation. Repair or replace as needed to ensure proper Semi - annually
operation.
Check control system and devices for evidence of improper operation. Repair, adjust or Semi- annually
replace components to ensure proper operation.
Check fan belt tension. Check for belt wear and proper alignment. Semi - annually b
Check control box for dirt, debris and/or loose terminations. Clean and tighten as needed. Annually
Check fan blades. Clean, repair or replace as needed to ensure proper operation.
Annually
Check drive alignment, wear, seating and operation. Repair and replace as needed.
Annually
Check draft inducer assemblies (where applicable)
Annually
Check air switches on power vented units
Annually
Check and set inlet gas pressure
Annually
Check and set manifold gas pressure
Annually
Check integrity of all panels on equipment. Replace fasteners as needed to ensure
Annually
proper integrity and fit /finish of equipment.
Lubricate field serviceable bearing.
Annually
Check for proper damper operation. Repair, replace or adjust as needed.
Annually
Check combustion chamber, burner and flue for deterioration, moisture problems,
Annually
condensation, and combustion products, including carbon monoxide analysis. Clean,
test and adjust combustion for proper operation.
Check heat exchanger. Clean as necessary to ensure proper operation and to remove Annually
scale and sediment. Check for possibility of leaks.
$ Filters changed quarterly with high efficiency pleated type.
b Replace belt annually.
MAKE -UP AIR UNITS
Inspection/Maintenance Task Frequency
Check air filter and housing integrity. At Filter Change 8
Check control system and devices for evidence of improper operation. Repair, adjust or Semi- annually
replace components to ensure proper operation.
Check air handling unit belt tension. Check for belt wear and proper alignment. Semi - annually b
Check variable frequency drive for proper operation. Correct as needed. Semi - annually
Check for proper operation and corrosion of heat exchanger. Clean, restore or replace as Semi - annually
required.
Check control box for dirt, debris and/or loose terminations. Clean and tighten as needed. Semi - annually
Check motor contactor for pitting or other signs of damage. Repair or replace as needed. Semi- annually
Check fan blades. Clean, repair or replace as needed to ensure proper operation. Semi - annually
Check for fouling, corrosion or degradation. Clean or repair as needed. Semi - annually
Check drive alignment, wear, seating and operation. Repair or replace as needed. Semi - annually
Check integrity of all panels on equipment. Replace fasteners as needed to ensure Semi - annually
proper integrity and fit /finish of equipment.
Lubricate field serviceable bearings. Semi - annually
Check and calibrate safety controls and cut -out devices Semi - annually
Check, calibrate and adjust operational controls Semi - annually
Check for proper venting of flue gases where applicable, and for gas leaks in and around Semi - annually
The heating unit immediate area.
Inspect dampers, linkage, positioning and operation. Lubricate dampers. Semi- annually
Check combustion chamber, burner and flue for deterioration, moisture problems, Semi- annually
condensation, and combustion products, including carbon monoxide analysis. Clean,
test and adjust combustion for proper operation.
Inspect heat exchanger. Clean as necessary to ensure proper operation and to remove Semi - annually
scale and sediment. Check for possibility of leaks.
a Filters changed quarterly with high efficiency pleated type.
b Replace belt annually.
PUMPS
Inspection/Maintenance Task Frequency
Check control system and devices for evidence of improper operation. Repair, adjust or Semi - annually
Replace components to ensure proper operation.
Check variable frequency drive for proper operation. Correct as needed. Semi - annually
Visually inspect pumps and associated electrical components. Repair or replace as Semi - annually
needed to ensure proper operation.
Inspect seals and connections for water leaks Semi- annually
Check coupling condition and security Semi- annually
Check control box for dirt, debris and/or loose terminations. Clean and tighten as needed. Annually
Check motor contactor for pitting or other signs of damage. Repair or replace as needed. Annually
Check drive alignment, wear, bearing and coupling seating and operation. Repair Annually
and replace as needed.
Check oil level where applicable Annually
Check for proper fluid flow. Clean, adjust and repair as needed to restore proper flow. Annually
Lubricate field serviceable bearings. Annually
REFRIGERATION SYSTEMS
Ins pection/Maintenance Task Frequency
Visually check condensing and evaporator sections for signs of damage or leaks. Quarterly
Inspect control panel, wiring, connections and insulation. Quarterly
Check compressor contactors or starters. Quarterly
Check suction and discharge pressures.
Quarterly
Check system sub cooling.
Quarterly
Check system superheat.
Quarterly
Adjust expansion valve superheat where applicable.
Quarterly
Adjust compressor un- loader actuators where applicable.
Quarterly
Check filter driers for restrictions.
Quarterly
Check sight glass indicator for moisture.
Quarterly
Check oil level and pressures.
Quarterly
Electrically test compressor motor windings.
Quarterly
Check defrost heaters, cycle and check amp draws.
Quarterly
Lubricate fan and motor bearings.
Quarterly
Check all controls for correct pressure settings.
Quarterly
Check safety and operating controls.
Quarterly
Pump down system to detect leaky or damaged compressor valves and liquid line
Quarterly
solenoids.
Check and clean all condensate pans and drains. Quarterly
Clean condenser and evaporator coils Quarterly
Verify all door and mullion heaters to be in proper working condition Quarterly
Verify all door gaskets, hinges, latches to be in proper working condition Quarterly
ROOFTOP UNITS
Inspection/Maintenance Task Frequency
Check air filter and housing integrity. At Filter Change'
Check system traps, pumps and controls. Clean or replace as needed to ensure proper Semi- annually
operation.
Check control system and devices for evidence of improper operation. Repair, adjust
Semi - annually
or replace components to ensure proper operation.
Check P -trap. Prime as needed to ensure proper operation.
Semi- annually
Check fan belt tension. Check for belt wear and proper alignment.
Semi - annually b
Check variable frequency drive for proper operation. Correct as needed.
Semi - annually
Check for proper operation of cooling or heating coil. Clean, restore or replace as
Semi - annually
required.
Check control box for dirt, debris and/or loose termination. Clean and tighten as needed. Annually
Check motor contactor for pitting or other signs of damage. Repair or replace as needed. Annually
Check fan blades. Clean, repair or replace as needed to ensure proper operation. Annually
Check refrigerant system pressures or temperatures. If outside of recommended levels, Annually
find cause, repair and adjust refrigerant to achieve optimal operating levels.
Check drive alignment, wear, seating and operation. Repair and replace as needed. Annually
Check integrity of all panels on equipment. Replace fasteners as needed to ensure Annually
proper integrity and fit /finish of equipment.
Lubricate field serviceable bearings. Annually
Check for evidence of build -up or fouling on heat exchange surfaces. Clean as needed Annually
to ensure proper operation.
Check drain pan, drain line and coil for biological growth. Clean as needed. Annually
Check evaporator coil fins. Restore if possible. Replace coil if necessary to return Annually
to proper functioning.
Inspect for evidence of moisture carryover beyond the drain pan from cooling coils. Annually
Make corrections or repairs as necessary.
Inspect dampers, linkage, positioning and operation. Lubricate dampers. Annually
Inspect air - cooled condenser surfaces. Repair or clean as needed. Annually
Check low ambient head pressure control sequence for proper operation. Repair or Annually
replace components or modify software /algorithm to ensure proper operation.
Check for excessive scale or debris on condenser surfaces. Clean as needed. Annually
ROOFTOP UNITS
inspectioWMaintenance Task Frequency
Check combustion chamber, burner and flue for deterioration, leaks, moisture problems, Annually
condensation, and combustion products. Clean, test and adjust combustion process for
proper operation, including monoxide analysis.
Visually inspect areas of moisture accumulation for biological growth. If present, clean Annually
or disinfect as needed.
Check condensate pump. Clean or replace. Annually
Check refrigerant oil levels for refrigerant systems with oil pressure /level controls. Annually
Repair, replace or adjust as needed to ensure proper operation.
Visually inspect exposed ductwork and external piping for insulation and vapor barrier Annually
for integrity. Correct as needed.
Visually inspect internally lined ductwork until the first turn or up to 20 feet into the Annually
supply plenum from air handler for integrity, and if soiled or degraded, correct.
Check and adjust all safety and operating controls Annually
Check and adjust thermostat (include daylight savings adjustment, where applicable) Annually
a Filters changed quarterly with high efficiency pleated type.
e Replace belt annually.
TEMPERATURE CONTROLS
Inspection/Maintenance Task Frequency
Visually inspect all temperature control components.
Verify all electrical connections for tightness and security.
Annually
Annually
Verify accuracy and calibrate all sensors or thermostats where applicable. Annually
Verify operations of all supporting actuators, valves, relays, zone controls. Annually
Provide adjustments to thermostats for Daylight Savings Time, where necessary Semi - annually
WATER HEATER
Inspection/Maintenance Task Frequency
Inspect flue venting
Inspect pilot and main burner assembly
Clean pilot and main burner assembly as required
Check for gas leaks in and around equipment immediate area
Check and adjust pilot and main burner for complete combustion and efficiency
Check operation of gas valve
Check for proper venting of flue gases
Perform complete combustion analysis
Check operations of pressure relief valve
Semi - annually
Semi - annually
Semi - annually
Semi - annually
Semi - annually
Semi - annually
Semi - annually
Semi-annually
Semi - annually
Flush heater utilizing drain valve where applicable Annually
CABINET HEATERS
Inspection/Maintenance Task Frequency
Check electrical connections for tightness Annually
Check for proper operation of operating controls Annually
Lubricate fan motor Annually
Visually check heating coil Annually
Check operations of heating valve where applicable Annually
Check integrity and security of all mounting hardware and access panels Annually
EXHAUST FANS
Inspection/Maintenance Task Frequency
Lubricate fan and motor bearings Annually
Inspect and adjust drive alignment and security
Inspect belt condition, change once a year
Check starter contacts where applicable
Annually
Annually
Annually
Clean exhaust fan wheel and exhaust screens as applicable Annually
SCHEDULE
C
ACORLIr CERTIFICATE OF LIABILITY INSURANCE
DATE(MM/DD/YYYY)
8/31 /2016
F
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to
the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsemen s .
PRODUCER
Cobb Strecker Dunphy & Zimmermann
150 South Fifth Street
CONTACT
Sara Collins
FAX
PHONE . 612 - 349 -2436
E-MAIL , scollins @csdz.com
Suite 2800
Minneapolis MN 55402
INSURER AFFORDING COVERAGE
NAICM
INSURERA :Zurich American Insurance Company
16535
COMMERCIAL GENERAL LIABILITY
INSURED HORWINCI
INSURERB:Travelers Casualty & Surety Co /Amer
31194
Horvitz, Inc.
4401 e N
New Hoo pe, , MN
MN 5 55428
INSURER C: American International Group
EACH OCCURRENCE
INSURERD :Catlin Specialty Insurance Company
15989
INSURER E :
INSURER F:
COVERAGES CERTIFICATE NLIMRFR• 255104128 ervlcmnsl ►,u 11"000.
III:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR
LTR
TYPE OF INSURANCE
INSD
WVD
POLICY NUMBER
POLICY EFF
MM1DD/YYYY
POLICY EXP
MM/DD/YYYY
LIMITS
A
X
COMMERCIAL GENERAL LIABILITY
GL0370323601
4/1/2016
4/1 /2017
EACH OCCURRENCE
$1,000,000
CLAIMS -MADE ❑ OCCUR
DAMAGE TO RENTED—
PREMISES Ea occurrence)
$300,000
X
MED EXP (Any one person)
$10,000
Contr Liab per-
X
PolicyForm/XCU
PERSONAL & ADV INJURY
$1,000,000
GEN'LAGGREGATE LIMIT APPLIES PER:
GENERAL AGGREGATE
$2,000,000
POLICY 1 JECT
LOC
PRODUCTS - COMP /OP AGG
$2,000,000
OTHER:
A
AUTOMOBILE
LIABILITY
BAP370323701
4/1/2016
4/1/2017
Ea MINED
$1,000,000
X
ANY AUTO
BODILY INJURY (Per person)
s
ALL OWNED SCHEDULED
AUTOS AUTOS
BODILY INJURY (Per accident)
S
HIRED AUTOS X NON -OWNED
AUTOS
X
PR
$
Per accdent
B
X
UMBRELLA LIAB
X
OCCUR
91M5528A
4/1/2016
4/1/2017
EACH OCCURRENCE
$5,000,000
EXCESS LIAR
CLAIMS -MADE
AGGREGATE
$5,000,000
DED I X I RETENTION $0
$
A
WORKERS COMPENSATION
WC370323501
4/1/2016
4/1/2017
X STATUTE I
AND EMPLOYERS' LIABILITY Y/ N
I ERH
E.L. EACH ACCIDENT
$1,000,000
ANY PROPRIETOR/PARTNER/EXECUTIVE
OFFICER /MEMBER EXCLUDED? FN
NIA
E.L. DISEASE - EA EMPLOYEd
$1,000,000
(Mandatory In NH)
If yes, describe under
E.L. DISEASE -POLICY LIMIT 1
$1,000,000
DESCRIPTION OF OPERATIONS below
A
C
Stop Gap
WC370323501
4/1/2016
4/112017
Applies to: ND, OH, WA WY
D
Pollution - Occurrence
CPO18337676
5/1012016
4/1/2018
Ea Loss: $2,000,000 A $2,000,000
Professional - Claims Made
CPV6903360916
9/1/2015
4/1/2017
Ea Claim: $3,000,000 Agg: $3,000,000
DESCRIPTION OF OPERATIONS / LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space Is required)
ALL WORK PERFORMED ADDITIONAL INSURED ONLY IF REQUIRED BY WRITTEN CONTRACT WITH RESPECT TO GENERAL
LIABILITY: CITY OF COLUMBIA HEIGHTS
CITY OF COLUMBIA HEIGHTS
590 40TH AVE NE
COLUMBIA HEIGHTS MN 55421 -3835
VAPIVGLLA I IVIY
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED
NTATIVE
@ 1988 -2014 ACORD CORPORATION- All rinhls ranarvarl
ACORD 25 (2014/01) The ACORD name and logo are registered marks of ACORD
SCHEDULE
Ic
�O/?[tJITZ
Building on 100 Years of
Innovation and Excellence
PROFESSIONAL SERVICE AGREEMENT
CITY OF COLUMBIA HEIGHTS, MINNESOTA
PUBLIC FACILITIES BUILDING MAITENANCE
FOR
HVAC AND REFRIGERATION SYSTEMS
Rates and Values
On -site response time:
Labor charged beyond this Agreement:
After -hours labor charge:
Holiday charge:
Over 12 hours per day:
Truck charge:
Service fee:
Parts mark -up:
2 hours
$118.80 /hour
Labor rate x 1.5
Labor rate x 2
Labor rate x 2
N/A
Waived
$0 -$100 Cost plus 50%
$101 -$500 Cost plus 33%
$501 and up Cost plus 25%
kwiP 4401 Quebec Avenue North • New Hope, MN 55428 • p: 763 - 533 -1900 • f: 763- 235 -9810 • www.horwitzinc.com